A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm
In order to test the S-parameters of non-coaxial RF (Radio Frequency) devices accurately, using, ADS (Advanced Design System) to simulate and design a set of fixture and calibration pieces for noncoaxial, RF device performance test, and the calibration pieces is used to calibrate the test fixture, r...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201817301005 |
_version_ | 1819132270565392384 |
---|---|
author | Shouhong Chen Zhuang Wang Jun Ma Xingna Hou |
author_facet | Shouhong Chen Zhuang Wang Jun Ma Xingna Hou |
author_sort | Shouhong Chen |
collection | DOAJ |
description | In order to test the S-parameters of non-coaxial RF (Radio Frequency) devices accurately, using, ADS (Advanced Design System) to simulate and design a set of fixture and calibration pieces for noncoaxial, RF device performance test, and the calibration pieces is used to calibrate the test fixture, remove, the error introduced by the fixture, and obtain the real S parameters of non-coaxial RF microwave devices.,Based on the study of various parameters of RF microwave devices, the Engen's TRL (Thru-Reflect-Line), calibration algorithm is studied in depth. An improved TRL calibration algorithm is proposed. And the use, of MATLAB program to achieve two calibration algorithms to correct the system error introduced by the measuring fixture, so as to get the real performance parameters of the device under test. Through the test of, the verification device, the agreement between the improved TRL algorithm and Engen's TRL algorithm is verified. The final design of the test fixture can be successfully applied to the network analyzer for noncoaxial, RF devices S-parameter measurement. |
first_indexed | 2024-12-22T09:28:44Z |
format | Article |
id | doaj.art-beaaebb4c2d14895a30dbc3aea2039ec |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-12-22T09:28:44Z |
publishDate | 2018-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-beaaebb4c2d14895a30dbc3aea2039ec2022-12-21T18:31:01ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011730100510.1051/matecconf/201817301005matecconf_smima2018_01005A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration AlgorithmShouhong ChenZhuang WangJun MaXingna HouIn order to test the S-parameters of non-coaxial RF (Radio Frequency) devices accurately, using, ADS (Advanced Design System) to simulate and design a set of fixture and calibration pieces for noncoaxial, RF device performance test, and the calibration pieces is used to calibrate the test fixture, remove, the error introduced by the fixture, and obtain the real S parameters of non-coaxial RF microwave devices.,Based on the study of various parameters of RF microwave devices, the Engen's TRL (Thru-Reflect-Line), calibration algorithm is studied in depth. An improved TRL calibration algorithm is proposed. And the use, of MATLAB program to achieve two calibration algorithms to correct the system error introduced by the measuring fixture, so as to get the real performance parameters of the device under test. Through the test of, the verification device, the agreement between the improved TRL algorithm and Engen's TRL algorithm is verified. The final design of the test fixture can be successfully applied to the network analyzer for noncoaxial, RF devices S-parameter measurement.https://doi.org/10.1051/matecconf/201817301005 |
spellingShingle | Shouhong Chen Zhuang Wang Jun Ma Xingna Hou A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm MATEC Web of Conferences |
title | A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm |
title_full | A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm |
title_fullStr | A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm |
title_full_unstemmed | A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm |
title_short | A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm |
title_sort | measurement of non coaxial rf devices with improved trl calibration algorithm |
url | https://doi.org/10.1051/matecconf/201817301005 |
work_keys_str_mv | AT shouhongchen ameasurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT zhuangwang ameasurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT junma ameasurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT xingnahou ameasurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT shouhongchen measurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT zhuangwang measurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT junma measurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm AT xingnahou measurementofnoncoaxialrfdeviceswithimprovedtrlcalibrationalgorithm |