High-Speed Temperature Measurement
In certain applications where temperature changes rapidly, e.g., compressor cylinder or explosion chamber, it is necessary to obtain temperature data with a sample rate high enough to register the change, i.e., the temperature probe response time must be very low. Type E coaxial thermocouples with r...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2022-01-01
|
Series: | EPJ Web of Conferences |
Online Access: | https://www.epj-conferences.org/articles/epjconf/pdf/2022/08/epjconf_efm2022_01006.pdf |
_version_ | 1828779984835051520 |
---|---|
author | Bouchal Patrik Hejčík Jiří Jícha Miroslav |
author_facet | Bouchal Patrik Hejčík Jiří Jícha Miroslav |
author_sort | Bouchal Patrik |
collection | DOAJ |
description | In certain applications where temperature changes rapidly, e.g., compressor cylinder or explosion chamber, it is necessary to obtain temperature data with a sample rate high enough to register the change, i.e., the temperature probe response time must be very low. Type E coaxial thermocouples with response time in the range of µs can be an example of such a temperature probe. This paper describes several approaches for high-frequency temperature data obtained using coaxial thermocouples. Individual approaches are described together, as well as their shortcomings. Furthermore, the possible method of data evaluation is discussed. |
first_indexed | 2024-12-11T17:11:08Z |
format | Article |
id | doaj.art-beb73d0cfed144c7b0d569fafebd3660 |
institution | Directory Open Access Journal |
issn | 2100-014X |
language | English |
last_indexed | 2024-12-11T17:11:08Z |
publishDate | 2022-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | EPJ Web of Conferences |
spelling | doaj.art-beb73d0cfed144c7b0d569fafebd36602022-12-22T00:57:32ZengEDP SciencesEPJ Web of Conferences2100-014X2022-01-012640100610.1051/epjconf/202226401006epjconf_efm2022_01006High-Speed Temperature MeasurementBouchal Patrik0Hejčík Jiří1Jícha Miroslav2Brno University of Technology, Department of Thermodynamics and Environmental EngineeringBrno University of Technology, Department of Thermodynamics and Environmental EngineeringBrno University of Technology, Department of Thermodynamics and Environmental EngineeringIn certain applications where temperature changes rapidly, e.g., compressor cylinder or explosion chamber, it is necessary to obtain temperature data with a sample rate high enough to register the change, i.e., the temperature probe response time must be very low. Type E coaxial thermocouples with response time in the range of µs can be an example of such a temperature probe. This paper describes several approaches for high-frequency temperature data obtained using coaxial thermocouples. Individual approaches are described together, as well as their shortcomings. Furthermore, the possible method of data evaluation is discussed.https://www.epj-conferences.org/articles/epjconf/pdf/2022/08/epjconf_efm2022_01006.pdf |
spellingShingle | Bouchal Patrik Hejčík Jiří Jícha Miroslav High-Speed Temperature Measurement EPJ Web of Conferences |
title | High-Speed Temperature Measurement |
title_full | High-Speed Temperature Measurement |
title_fullStr | High-Speed Temperature Measurement |
title_full_unstemmed | High-Speed Temperature Measurement |
title_short | High-Speed Temperature Measurement |
title_sort | high speed temperature measurement |
url | https://www.epj-conferences.org/articles/epjconf/pdf/2022/08/epjconf_efm2022_01006.pdf |
work_keys_str_mv | AT bouchalpatrik highspeedtemperaturemeasurement AT hejcikjiri highspeedtemperaturemeasurement AT jichamiroslav highspeedtemperaturemeasurement |