An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation
The microbond test has been widely adopted by researchers seeking to characterise the fibre-matrix interface in polymer composites. This test requires the preparation of polymer droplets with a mass as little as 20 ng. This brings with it the possibility of scaling issues causing unanticipated signi...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-07-01
|
Series: | Polymer Testing |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S0142941822001167 |
_version_ | 1818204193951842304 |
---|---|
author | James Thomason |
author_facet | James Thomason |
author_sort | James Thomason |
collection | DOAJ |
description | The microbond test has been widely adopted by researchers seeking to characterise the fibre-matrix interface in polymer composites. This test requires the preparation of polymer droplets with a mass as little as 20 ng. This brings with it the possibility of scaling issues causing unanticipated significant differences to the properties and performance of these droplets in comparison to macroscale samples. This paper reviews a number of these potential scaling issues in a range of polymer systems which users of the microbond test should be aware of. Some of these phenomena can affect the magnitude of the test results obtained much more than the fibre-matrix interface effects which the test is used to detect. It is concluded that in many cases the structure and properties of the polymer in such microdroplets is not representative of the same polymer, with the same thermal and environmental exposure history, prepared on the macroscale. |
first_indexed | 2024-12-12T03:37:21Z |
format | Article |
id | doaj.art-bf0bb3eab9b14cc4813b0451ca7ef43a |
institution | Directory Open Access Journal |
issn | 0142-9418 |
language | English |
last_indexed | 2024-12-12T03:37:21Z |
publishDate | 2022-07-01 |
publisher | Elsevier |
record_format | Article |
series | Polymer Testing |
spelling | doaj.art-bf0bb3eab9b14cc4813b0451ca7ef43a2022-12-22T00:39:46ZengElsevierPolymer Testing0142-94182022-07-01111107591An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisationJames Thomason0The University of Strathclyde, Department of Mechanical Engineering, 75 Montrose Street, United KingdomThe microbond test has been widely adopted by researchers seeking to characterise the fibre-matrix interface in polymer composites. This test requires the preparation of polymer droplets with a mass as little as 20 ng. This brings with it the possibility of scaling issues causing unanticipated significant differences to the properties and performance of these droplets in comparison to macroscale samples. This paper reviews a number of these potential scaling issues in a range of polymer systems which users of the microbond test should be aware of. Some of these phenomena can affect the magnitude of the test results obtained much more than the fibre-matrix interface effects which the test is used to detect. It is concluded that in many cases the structure and properties of the polymer in such microdroplets is not representative of the same polymer, with the same thermal and environmental exposure history, prepared on the macroscale.http://www.sciencedirect.com/science/article/pii/S0142941822001167Microbond testInterface/interphaseScaling |
spellingShingle | James Thomason An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation Polymer Testing Microbond test Interface/interphase Scaling |
title | An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation |
title_full | An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation |
title_fullStr | An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation |
title_full_unstemmed | An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation |
title_short | An overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre-matrix interface characterisation |
title_sort | overview of some scaling issues in the sample preparation and data interpretation of the microbond test for fibre matrix interface characterisation |
topic | Microbond test Interface/interphase Scaling |
url | http://www.sciencedirect.com/science/article/pii/S0142941822001167 |
work_keys_str_mv | AT jamesthomason anoverviewofsomescalingissuesinthesamplepreparationanddatainterpretationofthemicrobondtestforfibrematrixinterfacecharacterisation AT jamesthomason overviewofsomescalingissuesinthesamplepreparationanddatainterpretationofthemicrobondtestforfibrematrixinterfacecharacterisation |