Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”

If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual dose equivalent or effective dose. To take into...

Full description

Bibliographic Details
Main Authors: M. D. Pyshkina, A. V. Vasilyev, A. A. Ekidin, E. I. Nazarov, M. A. Romanova, V. I. Gurinovich, D. I. Komar, V. A. Kozhemyakin
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2021-06-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/804
_version_ 1797873812308492288
author M. D. Pyshkina
A. V. Vasilyev
A. A. Ekidin
E. I. Nazarov
M. A. Romanova
V. I. Gurinovich
D. I. Komar
V. A. Kozhemyakin
author_facet M. D. Pyshkina
A. V. Vasilyev
A. A. Ekidin
E. I. Nazarov
M. A. Romanova
V. I. Gurinovich
D. I. Komar
V. A. Kozhemyakin
author_sort M. D. Pyshkina
collection DOAJ
description If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual dose equivalent or effective dose. To take into account the energy distribution of the neutron radiation flux density and the geometry of the irradiation of workers, it is necessary to study the characteristics of the fields of neutron radiation at the workplaces of the personnel. In order to obtain conditionally true levels of personnel exposure to neutron radiation at nuclear facilities, studies of the energy and angular distribution of the neutron radiation flux density were carried out at the workplaces of the Institute of Reactor Materials JSC, Zarechny. The energy distribution of the neutron radiation flux density was obtained using an MKS-AT1117M multi-sphere dosimeter-radiometer with a BDKN-06 detection unit and a set of polyethylene spheres-moderators. The angular distribution of the neutron radiation flux density was estimated from the results of measurements of the accumulated dose of neutron radiation by individual thermoluminescent dosimeters placed on four vertical planes of a heterogeneous human phantom. The results of measurements of the energy and angular distribution of the neutron radiation flux density made it possible to estimate the conditionally true values of the ambient and individual dose equivalents. The calculated conventionally true values differ from the measured values from 0.7 to 8.9 times for the ambient dose equivalent and from 6 to 50 times for the individual dose equivalent. In order to reduce the error in assessing the effective dose of personnel using personal dosimeters, correction factors were determined. For different workplaces and types of personal dosimeters, correction factors are in the range of values from 0.02 to 0.16.
first_indexed 2024-04-10T01:21:00Z
format Article
id doaj.art-bf11362292e341ee9694b39d34f89e24
institution Directory Open Access Journal
issn 1998-426X
language English
last_indexed 2024-04-10T01:21:00Z
publishDate 2021-06-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj.art-bf11362292e341ee9694b39d34f89e242023-03-13T09:47:11ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2021-06-01142899910.21514/1998-426X-2021-14-2-89-99706Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”M. D. Pyshkina0A. V. Vasilyev1A. A. Ekidin2E. I. Nazarov3M. A. Romanova4V. I. Gurinovich5D. I. Komar6V. A. Kozhemyakin7Уральский федеральный университет; Институт промышленной экологии Уральского отделения Российской академии наукИнститут промышленной экологии Уральского отделения Российской академии наукИнститут промышленной экологии Уральского отделения Российской академии наукИнститут промышленной экологии Уральского отделения Российской академии наукУральский федеральный университет; Институт реакторных материаловНаучно-производственное унитарное предприятие «АТОМТЕХ»Научно-производственное унитарное предприятие «АТОМТЕХ»Научно-производственное унитарное предприятие «АТОМТЕХ»If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual dose equivalent or effective dose. To take into account the energy distribution of the neutron radiation flux density and the geometry of the irradiation of workers, it is necessary to study the characteristics of the fields of neutron radiation at the workplaces of the personnel. In order to obtain conditionally true levels of personnel exposure to neutron radiation at nuclear facilities, studies of the energy and angular distribution of the neutron radiation flux density were carried out at the workplaces of the Institute of Reactor Materials JSC, Zarechny. The energy distribution of the neutron radiation flux density was obtained using an MKS-AT1117M multi-sphere dosimeter-radiometer with a BDKN-06 detection unit and a set of polyethylene spheres-moderators. The angular distribution of the neutron radiation flux density was estimated from the results of measurements of the accumulated dose of neutron radiation by individual thermoluminescent dosimeters placed on four vertical planes of a heterogeneous human phantom. The results of measurements of the energy and angular distribution of the neutron radiation flux density made it possible to estimate the conditionally true values of the ambient and individual dose equivalents. The calculated conventionally true values differ from the measured values from 0.7 to 8.9 times for the ambient dose equivalent and from 6 to 50 times for the individual dose equivalent. In order to reduce the error in assessing the effective dose of personnel using personal dosimeters, correction factors were determined. For different workplaces and types of personal dosimeters, correction factors are in the range of values from 0.02 to 0.16.https://www.radhyg.ru/jour/article/view/804нейтроныдозиметр-радиометрпоправочный коэффициентгеометрия облучения
spellingShingle M. D. Pyshkina
A. V. Vasilyev
A. A. Ekidin
E. I. Nazarov
M. A. Romanova
V. I. Gurinovich
D. I. Komar
V. A. Kozhemyakin
Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
Радиационная гигиена
нейтроны
дозиметр-радиометр
поправочный коэффициент
геометрия облучения
title Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
title_full Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
title_fullStr Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
title_full_unstemmed Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
title_short Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
title_sort neutron dosimetry at workplaces of jc institute of nuclear materials
topic нейтроны
дозиметр-радиометр
поправочный коэффициент
геометрия облучения
url https://www.radhyg.ru/jour/article/view/804
work_keys_str_mv AT mdpyshkina neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT avvasilyev neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT aaekidin neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT einazarov neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT maromanova neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT vigurinovich neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT dikomar neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials
AT vakozhemyakin neutrondosimetryatworkplacesofjcinstituteofnuclearmaterials