PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING
Thirty-two adult patients after off-pump coronary artery bypass grafting were enrolled into a prospective observational study. All patients received positive end expiratory pressure test (PEEP-test), mini-fluid challenge test (mFCT) and standard fluid challenge test (sFCT). Pulse pressure variation...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
New Terra Publishing House
2018-11-01
|
Series: | Вестник анестезиологии и реаниматологии |
Subjects: | |
Online Access: | https://www.vair-journal.com/jour/article/view/274 |
_version_ | 1797700399366406144 |
---|---|
author | E. V. Fot N. N. Isotova A. A. Smetkin M. Yu. Kirov |
author_facet | E. V. Fot N. N. Isotova A. A. Smetkin M. Yu. Kirov |
author_sort | E. V. Fot |
collection | DOAJ |
description | Thirty-two adult patients after off-pump coronary artery bypass grafting were enrolled into a prospective observational study. All patients received positive end expiratory pressure test (PEEP-test), mini-fluid challenge test (mFCT) and standard fluid challenge test (sFCT). Pulse pressure variation using two monitoring systems (PPVPiCCO, PPVNK), Stroke volume variation (SVV), heart-lung index (HLI) and plethysmogram variability index (PVI) were assessed before and after sFCT. The patients with an increase in cardiac index by ≥15% after fluid challenge were defined as fluid responders. According to receiver operating characteristic analysis, changes in mean arterial pressure induced by PEEP-test identified fluid responsiveness with AUC 0.73 (p= 0.03). The reduction in PPVPiCCO and SVV during mFCT predicted positive response to the fluid load with AUC 0.77 and 0.75, respectively (p< 0.05). Response to sFLT can be predicted by the assessment of PPVPiCCO (AUC 0.84), PPVNK (AUC 0.71), SVV (AUC 0.77) and HLI (AUC 0.77) (p< 0.05). |
first_indexed | 2024-03-12T04:21:19Z |
format | Article |
id | doaj.art-bfa7729b31fb4716b4013da91ba58e77 |
institution | Directory Open Access Journal |
issn | 2078-5658 2541-8653 |
language | Russian |
last_indexed | 2024-03-12T04:21:19Z |
publishDate | 2018-11-01 |
publisher | New Terra Publishing House |
record_format | Article |
series | Вестник анестезиологии и реаниматологии |
spelling | doaj.art-bfa7729b31fb4716b4013da91ba58e772023-09-03T10:33:16ZrusNew Terra Publishing HouseВестник анестезиологии и реаниматологии2078-56582541-86532018-11-0115551310.21292/2078-5658-2018-15-5-5-13262PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTINGE. V. Fot0N. N. Isotova1A. A. Smetkin2M. Yu. Kirov3Северный государственный медицинский университет.Северный государственный медицинский университет.Северный государственный медицинский университет.Северный государственный медицинский университет.Thirty-two adult patients after off-pump coronary artery bypass grafting were enrolled into a prospective observational study. All patients received positive end expiratory pressure test (PEEP-test), mini-fluid challenge test (mFCT) and standard fluid challenge test (sFCT). Pulse pressure variation using two monitoring systems (PPVPiCCO, PPVNK), Stroke volume variation (SVV), heart-lung index (HLI) and plethysmogram variability index (PVI) were assessed before and after sFCT. The patients with an increase in cardiac index by ≥15% after fluid challenge were defined as fluid responders. According to receiver operating characteristic analysis, changes in mean arterial pressure induced by PEEP-test identified fluid responsiveness with AUC 0.73 (p= 0.03). The reduction in PPVPiCCO and SVV during mFCT predicted positive response to the fluid load with AUC 0.77 and 0.75, respectively (p< 0.05). Response to sFLT can be predicted by the assessment of PPVPiCCO (AUC 0.84), PPVNK (AUC 0.71), SVV (AUC 0.77) and HLI (AUC 0.77) (p< 0.05).https://www.vair-journal.com/jour/article/view/274восприимчивость к инфузионной нагрузкединамические показателидинамические тесты |
spellingShingle | E. V. Fot N. N. Isotova A. A. Smetkin M. Yu. Kirov PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING Вестник анестезиологии и реаниматологии восприимчивость к инфузионной нагрузке динамические показатели динамические тесты |
title | PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING |
title_full | PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING |
title_fullStr | PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING |
title_full_unstemmed | PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING |
title_short | PREDICT FLUID RESPONSIVENESS AFTER OFF-PUMP CORONARY ARTERY BYPASS GRAFTING |
title_sort | predict fluid responsiveness after off pump coronary artery bypass grafting |
topic | восприимчивость к инфузионной нагрузке динамические показатели динамические тесты |
url | https://www.vair-journal.com/jour/article/view/274 |
work_keys_str_mv | AT evfot predictfluidresponsivenessafteroffpumpcoronaryarterybypassgrafting AT nnisotova predictfluidresponsivenessafteroffpumpcoronaryarterybypassgrafting AT aasmetkin predictfluidresponsivenessafteroffpumpcoronaryarterybypassgrafting AT myukirov predictfluidresponsivenessafteroffpumpcoronaryarterybypassgrafting |