Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane

Purpose: to develop the optimal (safe and effective) method of diamond burr polishing of Bowman’s membrane (DBPBM) for the possible use it in the treatment of the recurrent corneal erosion syndrome (RCES) in the experiment.Material and methods. DBPBM in different modifications of the  method and the...

Full description

Bibliographic Details
Main Authors: S. V. Trufanov, A. A. Fedorov, V. R. Mamikonyan, L. Yu. Tekeeva, S. A. Malozhen, A. A. Karamyan
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2018-07-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/604
_version_ 1797875476944912384
author S. V. Trufanov
A. A. Fedorov
V. R. Mamikonyan
L. Yu. Tekeeva
S. A. Malozhen
A. A. Karamyan
author_facet S. V. Trufanov
A. A. Fedorov
V. R. Mamikonyan
L. Yu. Tekeeva
S. A. Malozhen
A. A. Karamyan
author_sort S. V. Trufanov
collection DOAJ
description Purpose: to develop the optimal (safe and effective) method of diamond burr polishing of Bowman’s membrane (DBPBM) for the possible use it in the treatment of the recurrent corneal erosion syndrome (RCES) in the experiment.Material and methods. DBPBM in different modifications of the  method and the mechanical deepithelization were performed in  experiment on 19 human cadaver eyes. We use system Ophtho-Burr  for DBPBM that includes a tip and ophthalmic burrs with diameter  1mm, 2.5 mm, 5 mm, varying the speed of rotation of burr. For 3  eyes — polishing with the application of burr with a diameter of 5  mm, the rotation frequency of 4000 rpm using 2 passes over the  surface of the cornea. For 3 eyes — burr with a diameter of 2.5 mm,  rotation frequency of 4000 rpm in 2 perpendicular passes. For 3 eyes — diameter burr 1 mm at speed of 8000 rpm in 2 perpendicular  passes. For 3 eyes — diameter burr 1 mm at speed 4000 rpm with 4  passes along the surface of the cornea. For 4 eyes — diameter was 1 mm at speed of 4000 rpm in 2 perpendicular passes. For 3 the eyes  was conducted mechanical deepithelization. Subsequent histopathological investigation of the cornea was  performed by method of semi-thin section, with polychrome staining.Results. The obtained results of histological studies of DBPBM in  different versions on cadaver cornea is allowed to choose the optimal variant of surgical intervention for use in clinical conditions. It  consisted in a selection of burr with a diameter of 1 mm, the rotation frequency of the 4000 rpm and 2 perpendicular passes with a  moderate compression of the cornea. The abovementioned technique of intervention allows removing completely the corneal epithelium  with a basal membrane and save uniform in thickness, fully  deepitelizationed Bowman’s membrane.Conclusion. Careful and accurate removal of dysplastic corneal epithelium in cases of the recurrent corneal erosion syndrome using  proposed method in clinical conditions should contribute to the  creation optimal environments for adequate reepithelization with  steady epithelial-stromal adhesion. The remaining nearly intact  Bowman’s membrane after procedure can prevent some postoperative complications such as haze and induced refractive disorders.
first_indexed 2024-04-10T01:48:07Z
format Article
id doaj.art-c00ab44cd9ce4a22a9d18b06dc36f636
institution Directory Open Access Journal
issn 1816-5095
2500-0845
language Russian
last_indexed 2024-04-10T01:48:07Z
publishDate 2018-07-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj.art-c00ab44cd9ce4a22a9d18b06dc36f6362023-03-13T09:08:38ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452018-07-0115217618110.18008/1816-5095-2018-2-176-181399Experimental Study of Diamond Burr Polishing Methods of Bowman’s MembraneS. V. Trufanov0A. A. Fedorov1V. R. Mamikonyan2L. Yu. Tekeeva3S. A. Malozhen4A. A. Karamyan5ФБГНУ «Научно-исследовательский институт глазных болезней»ФБГНУ «Научно-исследовательский институт глазных болезней»ФБГНУ «Научно-исследовательский институт глазных болезней»ФБГНУ «Научно-исследовательский институт глазных болезней»ФБГНУ «Научно-исследовательский институт глазных болезней»ФБГНУ «Научно-исследовательский институт глазных болезней»Purpose: to develop the optimal (safe and effective) method of diamond burr polishing of Bowman’s membrane (DBPBM) for the possible use it in the treatment of the recurrent corneal erosion syndrome (RCES) in the experiment.Material and methods. DBPBM in different modifications of the  method and the mechanical deepithelization were performed in  experiment on 19 human cadaver eyes. We use system Ophtho-Burr  for DBPBM that includes a tip and ophthalmic burrs with diameter  1mm, 2.5 mm, 5 mm, varying the speed of rotation of burr. For 3  eyes — polishing with the application of burr with a diameter of 5  mm, the rotation frequency of 4000 rpm using 2 passes over the  surface of the cornea. For 3 eyes — burr with a diameter of 2.5 mm,  rotation frequency of 4000 rpm in 2 perpendicular passes. For 3 eyes — diameter burr 1 mm at speed of 8000 rpm in 2 perpendicular  passes. For 3 eyes — diameter burr 1 mm at speed 4000 rpm with 4  passes along the surface of the cornea. For 4 eyes — diameter was 1 mm at speed of 4000 rpm in 2 perpendicular passes. For 3 the eyes  was conducted mechanical deepithelization. Subsequent histopathological investigation of the cornea was  performed by method of semi-thin section, with polychrome staining.Results. The obtained results of histological studies of DBPBM in  different versions on cadaver cornea is allowed to choose the optimal variant of surgical intervention for use in clinical conditions. It  consisted in a selection of burr with a diameter of 1 mm, the rotation frequency of the 4000 rpm and 2 perpendicular passes with a  moderate compression of the cornea. The abovementioned technique of intervention allows removing completely the corneal epithelium  with a basal membrane and save uniform in thickness, fully  deepitelizationed Bowman’s membrane.Conclusion. Careful and accurate removal of dysplastic corneal epithelium in cases of the recurrent corneal erosion syndrome using  proposed method in clinical conditions should contribute to the  creation optimal environments for adequate reepithelization with  steady epithelial-stromal adhesion. The remaining nearly intact  Bowman’s membrane after procedure can prevent some postoperative complications such as haze and induced refractive disorders.https://www.ophthalmojournal.com/opht/article/view/604эпителийроговицарецидивирующая эрозия роговицыповерхностная кератэктомияшлифовка боуменовой мембраны алмазным боромкадаверные глаза
spellingShingle S. V. Trufanov
A. A. Fedorov
V. R. Mamikonyan
L. Yu. Tekeeva
S. A. Malozhen
A. A. Karamyan
Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
Oftalʹmologiâ
эпителий
роговица
рецидивирующая эрозия роговицы
поверхностная кератэктомия
шлифовка боуменовой мембраны алмазным бором
кадаверные глаза
title Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
title_full Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
title_fullStr Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
title_full_unstemmed Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
title_short Experimental Study of Diamond Burr Polishing Methods of Bowman’s Membrane
title_sort experimental study of diamond burr polishing methods of bowman s membrane
topic эпителий
роговица
рецидивирующая эрозия роговицы
поверхностная кератэктомия
шлифовка боуменовой мембраны алмазным бором
кадаверные глаза
url https://www.ophthalmojournal.com/opht/article/view/604
work_keys_str_mv AT svtrufanov experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane
AT aafedorov experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane
AT vrmamikonyan experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane
AT lyutekeeva experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane
AT samalozhen experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane
AT aakaramyan experimentalstudyofdiamondburrpolishingmethodsofbowmansmembrane