Icreasing the efficiency of district heating supply systems by local heat distribution station modernation

The PURPOSE of the study is to improve the efficiency of district heating systems. To achieve this purpose, the following tasks must be completed. To consider the problems of functioning of an open heat supply system functioning. Perform an analysis of technical solutions for the modernization of lo...

Full description

Bibliographic Details
Main Authors: Yu. A. Gorinov, P. N. Anisimov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2022-06-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/2230
_version_ 1797762217712549888
author Yu. A. Gorinov
P. N. Anisimov
author_facet Yu. A. Gorinov
P. N. Anisimov
author_sort Yu. A. Gorinov
collection DOAJ
description The PURPOSE of the study is to improve the efficiency of district heating systems. To achieve this purpose, the following tasks must be completed. To consider the problems of functioning of an open heat supply system functioning. Perform an analysis of technical solutions for the modernization of local heat distribution and metering station are presented. To develop a technological scheme of local heat distribution station with a hot-water supply system. To determine the main technical, economic and investment indicators of the developed technical solution.MATERIALS AND METHODS. Measurements were made using the local heat metering station. When solving the set tasks, a methodology for assessing efficiency was applied with the calculation of capital and operating costs, including the calculation of the payback period.RESULTS. A new scheme for regulating of hot water supply system recirculation with open connection of consumers to a centralized source is proposed. The results of the implementation of the developed technical solution of local heat distribution and metering station for apartment buildings in Yoshkar-Ola city are presented. An experimental study of the effect of a joint additional installation of a pump and a control valve on the hot water supply system recirculation line before the mixing unit for hot water recirculation with return pipe and before the direct-acting temperature controller was the first to do. As a result, the consumption of district water was reduced by 36 - 39%, the temperature in the return pipeline was reduced by 13.5%; the enthalpy of the hot water was reduced from 0.168 to 0.145 Gcal/m3, the required circulation in all risers of the hot water supply system was ensured.CONCLUSION. The use of the developed technical solution for the modernization of local heat distribution and metering station increases the efficiency of district heating supply systems. Calculations made on the basis of the readings of automatic custody heat transfer meter showed that the payback period for the technical solution is 40 days. The proposed solution is recommended for use in local heat distribution station of open heat supply system in order to reduce water rate, lower the temperature in the return pipeline and reduce heat losses, improve circulation in all riser pipes of the hot water system.
first_indexed 2024-03-12T19:24:07Z
format Article
id doaj.art-c0375a7780fb47a58b30b8085ce7a387
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2024-03-12T19:24:07Z
publishDate 2022-06-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-c0375a7780fb47a58b30b8085ce7a3872023-08-02T04:57:43ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032022-06-0124310111110.30724/1998-9903-2022-24-3-101-111859Icreasing the efficiency of district heating supply systems by local heat distribution station modernationYu. A. Gorinov0P. N. Anisimov1Pavoolga State University of Technology; MUP «Yoshkar-Olinskaya CHPP-1»Pavoolga State University of TechnologyThe PURPOSE of the study is to improve the efficiency of district heating systems. To achieve this purpose, the following tasks must be completed. To consider the problems of functioning of an open heat supply system functioning. Perform an analysis of technical solutions for the modernization of local heat distribution and metering station are presented. To develop a technological scheme of local heat distribution station with a hot-water supply system. To determine the main technical, economic and investment indicators of the developed technical solution.MATERIALS AND METHODS. Measurements were made using the local heat metering station. When solving the set tasks, a methodology for assessing efficiency was applied with the calculation of capital and operating costs, including the calculation of the payback period.RESULTS. A new scheme for regulating of hot water supply system recirculation with open connection of consumers to a centralized source is proposed. The results of the implementation of the developed technical solution of local heat distribution and metering station for apartment buildings in Yoshkar-Ola city are presented. An experimental study of the effect of a joint additional installation of a pump and a control valve on the hot water supply system recirculation line before the mixing unit for hot water recirculation with return pipe and before the direct-acting temperature controller was the first to do. As a result, the consumption of district water was reduced by 36 - 39%, the temperature in the return pipeline was reduced by 13.5%; the enthalpy of the hot water was reduced from 0.168 to 0.145 Gcal/m3, the required circulation in all risers of the hot water supply system was ensured.CONCLUSION. The use of the developed technical solution for the modernization of local heat distribution and metering station increases the efficiency of district heating supply systems. Calculations made on the basis of the readings of automatic custody heat transfer meter showed that the payback period for the technical solution is 40 days. The proposed solution is recommended for use in local heat distribution station of open heat supply system in order to reduce water rate, lower the temperature in the return pipeline and reduce heat losses, improve circulation in all riser pipes of the hot water system.https://www.energyret.ru/jour/article/view/2230energy systems and complexesdistrict heating supply systemopen heat supply systemlocal heat distribution and metering stationhot water supply systemeconomic efficiency
spellingShingle Yu. A. Gorinov
P. N. Anisimov
Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
Известия высших учебных заведений: Проблемы энергетики
energy systems and complexes
district heating supply system
open heat supply system
local heat distribution and metering station
hot water supply system
economic efficiency
title Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
title_full Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
title_fullStr Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
title_full_unstemmed Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
title_short Icreasing the efficiency of district heating supply systems by local heat distribution station modernation
title_sort icreasing the efficiency of district heating supply systems by local heat distribution station modernation
topic energy systems and complexes
district heating supply system
open heat supply system
local heat distribution and metering station
hot water supply system
economic efficiency
url https://www.energyret.ru/jour/article/view/2230
work_keys_str_mv AT yuagorinov icreasingtheefficiencyofdistrictheatingsupplysystemsbylocalheatdistributionstationmodernation
AT pnanisimov icreasingtheefficiencyofdistrictheatingsupplysystemsbylocalheatdistributionstationmodernation