Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens
Purpose: to carry out a comparative analysis of refractive outcomes and features during preoperational calculation of the biplanar intraocular lens (IOL) with iridocapsular and iridovitreal fixation.Patients and methods. Study included the analysis IOL model RSP-3 implantation after phacoemulsificat...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Ophthalmology Publishing Group
2018-07-01
|
Series: | Oftalʹmologiâ |
Subjects: | |
Online Access: | https://www.ophthalmojournal.com/opht/article/view/599 |
_version_ | 1797875477852979200 |
---|---|
author | B. E. Malyugin E. N. Panteleev A. N. Bessarabov D. F. Pokrovskiy A. S. Semakina S. A. Abdullaeva |
author_facet | B. E. Malyugin E. N. Panteleev A. N. Bessarabov D. F. Pokrovskiy A. S. Semakina S. A. Abdullaeva |
author_sort | B. E. Malyugin |
collection | DOAJ |
description | Purpose: to carry out a comparative analysis of refractive outcomes and features during preoperational calculation of the biplanar intraocular lens (IOL) with iridocapsular and iridovitreal fixation.Patients and methods. Study included the analysis IOL model RSP-3 implantation after phacoemulsification cataract surgery with subluxated lens grade 2. Analyzed 309 eyes of 304 patients with iridocapsular (n = 44) (ICF) and iridovitreal fixation (n = 265) (IVF). In both groups IOL power was calculated with use of A- constant (118.2) recommended by manufacturer. Mean period of examination was 6 months. To count optimized A-constant in both groups we used next data: IOL power and axial length before surgery, keratometry, spherical equivalent and IOL effective position during 6 months after surgery.Results. In group with ICF postoperative refraction was achieved ± 0,5 D in 10 cases (23%), in group IVF — in 29 cases (11%). Mean value of optimized A-constant for IOL model RSP-3 in groups with ICF and IVF were 117.2 ± 1.18 (114.0–120.8) and 116.9 ± 1,89 (109.6 до 123.6). There were no statistically significant difference between compared groups (p = 0.46).Conclusion. Use of A-constant recommended by manufacturer do not allow achieving target refraction in most cases. Mean values of biplanar IOL A-constant counted for ICF and IVF were 117,2 and 116,9 respectively, what should be taken into account during IOL power count, according to its fixation method. |
first_indexed | 2024-04-10T01:48:08Z |
format | Article |
id | doaj.art-c100f6ac0e3a403f979b16746c907dbb |
institution | Directory Open Access Journal |
issn | 1816-5095 2500-0845 |
language | Russian |
last_indexed | 2024-04-10T01:48:08Z |
publishDate | 2018-07-01 |
publisher | Ophthalmology Publishing Group |
record_format | Article |
series | Oftalʹmologiâ |
spelling | doaj.art-c100f6ac0e3a403f979b16746c907dbb2023-03-13T09:08:38ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452018-07-0115213914510.18008/1816-5095-2018-2-139-145394Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular LensB. E. Malyugin0E. N. Panteleev1A. N. Bessarabov2D. F. Pokrovskiy3A. S. Semakina4S. A. Abdullaeva5ФГАУ «МНТК “Микрохирургия глаза” им. академика С.Н. Федорова» Министерства здравоохранения Российской ФедерацииФГАУ «МНТК “Микрохирургия глаза” им. академика С.Н. Федорова» Министерства здравоохранения Российской ФедерацииФГАУ «МНТК “Микрохирургия глаза” им. академика С.Н. Федорова» Министерства здравоохранения Российской ФедерацииФГБОУ ВО «Российский национальный исследовательский медицинский университет имени Н.И. Пирогова» Министерства здравоохранения Российской ФедерацииФГАУ «МНТК “Микрохирургия глаза” им. академика С.Н. Федорова» Министерства здравоохранения Российской ФедерацииФГАУ «МНТК “Микрохирургия глаза” им. академика С.Н. Федорова» Министерства здравоохранения Российской ФедерацииPurpose: to carry out a comparative analysis of refractive outcomes and features during preoperational calculation of the biplanar intraocular lens (IOL) with iridocapsular and iridovitreal fixation.Patients and methods. Study included the analysis IOL model RSP-3 implantation after phacoemulsification cataract surgery with subluxated lens grade 2. Analyzed 309 eyes of 304 patients with iridocapsular (n = 44) (ICF) and iridovitreal fixation (n = 265) (IVF). In both groups IOL power was calculated with use of A- constant (118.2) recommended by manufacturer. Mean period of examination was 6 months. To count optimized A-constant in both groups we used next data: IOL power and axial length before surgery, keratometry, spherical equivalent and IOL effective position during 6 months after surgery.Results. In group with ICF postoperative refraction was achieved ± 0,5 D in 10 cases (23%), in group IVF — in 29 cases (11%). Mean value of optimized A-constant for IOL model RSP-3 in groups with ICF and IVF were 117.2 ± 1.18 (114.0–120.8) and 116.9 ± 1,89 (109.6 до 123.6). There were no statistically significant difference between compared groups (p = 0.46).Conclusion. Use of A-constant recommended by manufacturer do not allow achieving target refraction in most cases. Mean values of biplanar IOL A-constant counted for ICF and IVF were 117,2 and 116,9 respectively, what should be taken into account during IOL power count, according to its fixation method.https://www.ophthalmojournal.com/opht/article/view/599рсп-3а-константаиридо-капсульная фиксациядвухплоскостная иол |
spellingShingle | B. E. Malyugin E. N. Panteleev A. N. Bessarabov D. F. Pokrovskiy A. S. Semakina S. A. Abdullaeva Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens Oftalʹmologiâ рсп-3 а-константа иридо-капсульная фиксация двухплоскостная иол |
title | Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens |
title_full | Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens |
title_fullStr | Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens |
title_full_unstemmed | Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens |
title_short | Comparative Analysis of Refractive Result Predictability During Iridocapsular and Iridovitreal Fixation of Biplanar Intraocular Lens |
title_sort | comparative analysis of refractive result predictability during iridocapsular and iridovitreal fixation of biplanar intraocular lens |
topic | рсп-3 а-константа иридо-капсульная фиксация двухплоскостная иол |
url | https://www.ophthalmojournal.com/opht/article/view/599 |
work_keys_str_mv | AT bemalyugin comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens AT enpanteleev comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens AT anbessarabov comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens AT dfpokrovskiy comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens AT assemakina comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens AT saabdullaeva comparativeanalysisofrefractiveresultpredictabilityduringiridocapsularandiridovitrealfixationofbiplanarintraocularlens |