Dose-volume histogram quality assurance for linac-based treatment planning systems
Dose-volume histograms provide key information to radiation oncologists when they assess the adequacy of a patient treatment plan in radiation therapy. It is important therefore that all clinically relevant data be accurate. In this article we present the first quality assurance routine involving a...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2010-01-01
|
Series: | Journal of Medical Physics |
Subjects: | |
Online Access: | http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=197;epage=201;aulast=Gossman |
_version_ | 1818556908771999744 |
---|---|
author | Gossman Michael Bank Morris |
author_facet | Gossman Michael Bank Morris |
author_sort | Gossman Michael |
collection | DOAJ |
description | Dose-volume histograms provide key information to radiation oncologists when they assess the adequacy of a patient treatment plan in radiation therapy. It is important therefore that all clinically relevant data be accurate. In this article we present the first quality assurance routine involving a direct comparison of planning system results with the results obtained from independent hand calculations. Given a known three-dimensional (3-D) structure such as a parallelepiped, a simple beam arrangement, and known physics beam data, a time-efficient and reproducible method for verifying the accuracy of volumetric statistics (DVH) from a radiation therapy treatment planning system (TPS) can be employed rapidly, satisfying the QA requirements for (TPS) commissioning, upgrades, and annual checks. Using this method, the maximum disagreement was only 1.7% for 6 MV and 1.3% for 18 MV photon energies. The average accuracy was within 0.6% for 6 MV and 0.4% for 18 MV for all depth-dose results. A 2% disagreement was observed with the treatment planning system DVH from defined volume comparison to the known structure dimensions. |
first_indexed | 2024-12-13T23:53:17Z |
format | Article |
id | doaj.art-c123d0bebab74038a4bbce456442ba33 |
institution | Directory Open Access Journal |
issn | 0971-6203 1998-3913 |
language | English |
last_indexed | 2024-12-13T23:53:17Z |
publishDate | 2010-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Journal of Medical Physics |
spelling | doaj.art-c123d0bebab74038a4bbce456442ba332022-12-21T23:26:41ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132010-01-01354197201Dose-volume histogram quality assurance for linac-based treatment planning systemsGossman MichaelBank MorrisDose-volume histograms provide key information to radiation oncologists when they assess the adequacy of a patient treatment plan in radiation therapy. It is important therefore that all clinically relevant data be accurate. In this article we present the first quality assurance routine involving a direct comparison of planning system results with the results obtained from independent hand calculations. Given a known three-dimensional (3-D) structure such as a parallelepiped, a simple beam arrangement, and known physics beam data, a time-efficient and reproducible method for verifying the accuracy of volumetric statistics (DVH) from a radiation therapy treatment planning system (TPS) can be employed rapidly, satisfying the QA requirements for (TPS) commissioning, upgrades, and annual checks. Using this method, the maximum disagreement was only 1.7% for 6 MV and 1.3% for 18 MV photon energies. The average accuracy was within 0.6% for 6 MV and 0.4% for 18 MV for all depth-dose results. A 2% disagreement was observed with the treatment planning system DVH from defined volume comparison to the known structure dimensions.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=197;epage=201;aulast=GossmanDosedose-volumedose-volume histogramhistogramquality assurancetreatment planning systemVolume |
spellingShingle | Gossman Michael Bank Morris Dose-volume histogram quality assurance for linac-based treatment planning systems Journal of Medical Physics Dose dose-volume dose-volume histogram histogram quality assurance treatment planning system Volume |
title | Dose-volume histogram quality assurance for linac-based treatment planning systems |
title_full | Dose-volume histogram quality assurance for linac-based treatment planning systems |
title_fullStr | Dose-volume histogram quality assurance for linac-based treatment planning systems |
title_full_unstemmed | Dose-volume histogram quality assurance for linac-based treatment planning systems |
title_short | Dose-volume histogram quality assurance for linac-based treatment planning systems |
title_sort | dose volume histogram quality assurance for linac based treatment planning systems |
topic | Dose dose-volume dose-volume histogram histogram quality assurance treatment planning system Volume |
url | http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=197;epage=201;aulast=Gossman |
work_keys_str_mv | AT gossmanmichael dosevolumehistogramqualityassuranceforlinacbasedtreatmentplanningsystems AT bankmorris dosevolumehistogramqualityassuranceforlinacbasedtreatmentplanningsystems |