Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment
The advanced oxidation processes (AOPs) were assessed for enhancing the treatment of stabilized landfill leachate previously pretreated using coagulation-flocculation (C-F).The primary treatment by C-F using 20 g.L−1 of FeCl3 (optimal coagulant dosage) has removed 71% of chemical oxidation demand (C...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-09-01
|
Series: | Scientific African |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2468227622002198 |
_version_ | 1798029194119086080 |
---|---|
author | Hamza Bellouk Imane El Mrabet Karim Tanji Mostafa Nawdali Mourad Benzina Mabrouk Eloussaief Hicham Zaitan |
author_facet | Hamza Bellouk Imane El Mrabet Karim Tanji Mostafa Nawdali Mourad Benzina Mabrouk Eloussaief Hicham Zaitan |
author_sort | Hamza Bellouk |
collection | DOAJ |
description | The advanced oxidation processes (AOPs) were assessed for enhancing the treatment of stabilized landfill leachate previously pretreated using coagulation-flocculation (C-F).The primary treatment by C-F using 20 g.L−1 of FeCl3 (optimal coagulant dosage) has removed 71% of chemical oxidation demand (COD) and 95% of turbidity. Thereafter, secondary treatment was applied using different system combinations of two inorganic oxidants (potassium persulfate, K2S2O8 (PS) (1500 mg. L−1) and hydrogen peroxide, H2O2 (1327 mg. L−1)) that were used simultaneously or separately with UV-A and/or ultrasonic (US) irradiations.The obtained results indicated that the oxidation systems with the presence of H2O2 were more efficient than other systems. Indeed, the H2O2-PS-US-UV-A system reached the highest COD removal of 89%, while PS-based combinations were the less efficient (PS alone 19%, PS-UV-A 22%, PS-US 32%, and PS-US-UV-A 35%).Hence, the sequential process including C-F as pretreatment followed by the application of the H2O2-PS-US-UV-A system has proven high efficiency for COD removal, absorbance at 254 nm, and color number of 97%, 97%, and 99%, respectively.The sequential application of AOPs after preliminary treatment using coagulation-flocculation is a promising alternative to reducing the high organic load of stabilized leachate and that could be largely applied to other types of effluents. |
first_indexed | 2024-04-11T19:21:18Z |
format | Article |
id | doaj.art-c204ffe2d1f747b483ac73a5b2b05870 |
institution | Directory Open Access Journal |
issn | 2468-2276 |
language | English |
last_indexed | 2024-04-11T19:21:18Z |
publishDate | 2022-09-01 |
publisher | Elsevier |
record_format | Article |
series | Scientific African |
spelling | doaj.art-c204ffe2d1f747b483ac73a5b2b058702022-12-22T04:07:18ZengElsevierScientific African2468-22762022-09-0117e01312Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatmentHamza Bellouk0Imane El Mrabet1Karim Tanji2Mostafa Nawdali3Mourad Benzina4Mabrouk Eloussaief5Hicham Zaitan6Processes, Materials and Environment Laboratory (LPME), Faculty of Sciences and Technology of Fez, Sidi Mohamed Ben Abdellah University, BP 2202, MoroccoDepartment of Physics-Chemistry, Polydisciplinary Faculty of Ouarzazate, University of Ibn Zohr, Morocco; Corresponding authors.Independent Scientist, Sidi Mohamed Ben Abdellah University, Fez, MoroccoProcesses, Materials and Environment Laboratory (LPME), Faculty of Sciences and Technology of Fez, Sidi Mohamed Ben Abdellah University, BP 2202, MoroccoLaboratory ''Water, Energy and Environment'' (LR3E), National Engineering School of Sfax, University of Sfax, TunisiaLaboratory ''Water, Energy and Environment'' (LR3E), National Engineering School of Sfax, University of Sfax, TunisiaProcesses, Materials and Environment Laboratory (LPME), Faculty of Sciences and Technology of Fez, Sidi Mohamed Ben Abdellah University, BP 2202, Morocco; Corresponding authors.The advanced oxidation processes (AOPs) were assessed for enhancing the treatment of stabilized landfill leachate previously pretreated using coagulation-flocculation (C-F).The primary treatment by C-F using 20 g.L−1 of FeCl3 (optimal coagulant dosage) has removed 71% of chemical oxidation demand (COD) and 95% of turbidity. Thereafter, secondary treatment was applied using different system combinations of two inorganic oxidants (potassium persulfate, K2S2O8 (PS) (1500 mg. L−1) and hydrogen peroxide, H2O2 (1327 mg. L−1)) that were used simultaneously or separately with UV-A and/or ultrasonic (US) irradiations.The obtained results indicated that the oxidation systems with the presence of H2O2 were more efficient than other systems. Indeed, the H2O2-PS-US-UV-A system reached the highest COD removal of 89%, while PS-based combinations were the less efficient (PS alone 19%, PS-UV-A 22%, PS-US 32%, and PS-US-UV-A 35%).Hence, the sequential process including C-F as pretreatment followed by the application of the H2O2-PS-US-UV-A system has proven high efficiency for COD removal, absorbance at 254 nm, and color number of 97%, 97%, and 99%, respectively.The sequential application of AOPs after preliminary treatment using coagulation-flocculation is a promising alternative to reducing the high organic load of stabilized leachate and that could be largely applied to other types of effluents.http://www.sciencedirect.com/science/article/pii/S2468227622002198Landfill leachate treatmentUltrasound-activated persulfateUltraviolet irradiationHydroxyl radicalsOrganic contaminants removal |
spellingShingle | Hamza Bellouk Imane El Mrabet Karim Tanji Mostafa Nawdali Mourad Benzina Mabrouk Eloussaief Hicham Zaitan Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment Scientific African Landfill leachate treatment Ultrasound-activated persulfate Ultraviolet irradiation Hydroxyl radicals Organic contaminants removal |
title | Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment |
title_full | Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment |
title_fullStr | Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment |
title_full_unstemmed | Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment |
title_short | Performance of coagulation-flocculation followed by ultra-violet/ultrasound activated persulfate/hydrogen peroxide for landfill leachate treatment |
title_sort | performance of coagulation flocculation followed by ultra violet ultrasound activated persulfate hydrogen peroxide for landfill leachate treatment |
topic | Landfill leachate treatment Ultrasound-activated persulfate Ultraviolet irradiation Hydroxyl radicals Organic contaminants removal |
url | http://www.sciencedirect.com/science/article/pii/S2468227622002198 |
work_keys_str_mv | AT hamzabellouk performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT imaneelmrabet performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT karimtanji performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT mostafanawdali performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT mouradbenzina performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT mabroukeloussaief performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment AT hichamzaitan performanceofcoagulationflocculationfollowedbyultravioletultrasoundactivatedpersulfatehydrogenperoxideforlandfillleachatetreatment |