Surgical Management of a Mandible Subcondylar Fracture

Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when...

Full description

Bibliographic Details
Main Author: Dong Hee Kang
Format: Article
Language:English
Published: Thieme Medical Publishers, Inc. 2012-07-01
Series:Archives of Plastic Surgery
Subjects:
Online Access:http://www.e-aps.org/upload/pdf/aps-39-284.pdf
_version_ 1828150485215870976
author Dong Hee Kang
author_facet Dong Hee Kang
author_sort Dong Hee Kang
collection DOAJ
description Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.
first_indexed 2024-04-11T21:45:12Z
format Article
id doaj.art-c22f2981e1bb46e29db3a916543020cc
institution Directory Open Access Journal
issn 2234-6163
2234-6171
language English
last_indexed 2024-04-11T21:45:12Z
publishDate 2012-07-01
publisher Thieme Medical Publishers, Inc.
record_format Article
series Archives of Plastic Surgery
spelling doaj.art-c22f2981e1bb46e29db3a916543020cc2022-12-22T04:01:27ZengThieme Medical Publishers, Inc.Archives of Plastic Surgery2234-61632234-61712012-07-0139428429044Surgical Management of a Mandible Subcondylar FractureDong Hee Kang0Department of Plastic Surgery , Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea.Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.http://www.e-aps.org/upload/pdf/aps-39-284.pdfFracture fixationMandibular condyleMandibular fractures
spellingShingle Dong Hee Kang
Surgical Management of a Mandible Subcondylar Fracture
Archives of Plastic Surgery
Fracture fixation
Mandibular condyle
Mandibular fractures
title Surgical Management of a Mandible Subcondylar Fracture
title_full Surgical Management of a Mandible Subcondylar Fracture
title_fullStr Surgical Management of a Mandible Subcondylar Fracture
title_full_unstemmed Surgical Management of a Mandible Subcondylar Fracture
title_short Surgical Management of a Mandible Subcondylar Fracture
title_sort surgical management of a mandible subcondylar fracture
topic Fracture fixation
Mandibular condyle
Mandibular fractures
url http://www.e-aps.org/upload/pdf/aps-39-284.pdf
work_keys_str_mv AT dongheekang surgicalmanagementofamandiblesubcondylarfracture