Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics

The ongoing climate change and policies around it are changing how we design and build homes to meet national carbon emission targets. Some countries such as Scotland are adopting higher-energy-efficient buildings as minimum requirements in the building regulations. While net zero homes might be mor...

Full description

Bibliographic Details
Main Authors: Alejandro Moreno-Rangel, Tim Sharpe, Gráinne McGill, Filbert Musau
Format: Article
Language:English
Published: MDPI AG 2023-06-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/13/6/1518
_version_ 1797595700409663488
author Alejandro Moreno-Rangel
Tim Sharpe
Gráinne McGill
Filbert Musau
author_facet Alejandro Moreno-Rangel
Tim Sharpe
Gráinne McGill
Filbert Musau
author_sort Alejandro Moreno-Rangel
collection DOAJ
description The ongoing climate change and policies around it are changing how we design and build homes to meet national carbon emission targets. Some countries such as Scotland are adopting higher-energy-efficient buildings as minimum requirements in the building regulations. While net zero homes might be more energy-efficient and emit fewer operational carbon emissions, we have yet to fully understand the influence on the indoor environment, particularly on indoor air quality (IAQ) and thermal comfort. This study compares the IAQ of three homes in Scotland with equal internal layouts and designs but different building fabrics. The homes represent the minimum Scottish building regulations (2015), the Passivhaus standard and the Scottish ‘Gold Standard’. Temperature, relative humidity, PM<sub>2.5</sub> and total volatile organic compounds (tVOC) were measured at five-minute intervals for seven months and compared to occupants’ subjective responses to the IAQ. All three homes had temperatures above the recommended thresholds for overheating. Measured hygrothermal conditions were within the ideal range 66.4% of the time in the Passivhaus, 56.4% in the Gold Standard home and 62.7% in the control home. Measured IAQ was better in homes with higher energy efficiency, particularly tVOC. For instance, indoor PM<sub>2.5</sub> in the Passivhaus were 78.0% of the time below the threshold, while in the standard home the figure was 51.5%, with a weak correlation with outdoor PM<sub>2.5</sub> (Passivhaus: B r<sub>s</sub> = 0.167, K r<sub>s</sub> = 0.306 and L r<sub>s</sub> = 0.163 (<i>p</i> < 0.001); Gold: B r<sub>s</sub> = −0.157, K r<sub>s</sub> = 0.322 and L r<sub>s</sub> = 0.340 (<i>p</i> < 0.001); Control: B r<sub>s</sub> = −0.111, K r<sub>s</sub> = 0.235 and L r<sub>s</sub> = 0.235 (<i>p</i> < 0.001)). TVOCs in the Passivhaus were 81.3%, while in the control home they were 55.0%. While the results cannot be generalised, due to the small sample, this study has significant policy implications, particularly in Scotland, exhibiting the importance of IAQ in current building legislation and sustainable assessment methods.
first_indexed 2024-03-11T02:40:05Z
format Article
id doaj.art-c2998c098a0240eba31099060fcfe1d0
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-11T02:40:05Z
publishDate 2023-06-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-c2998c098a0240eba31099060fcfe1d02023-11-18T09:39:22ZengMDPI AGBuildings2075-53092023-06-01136151810.3390/buildings13061518Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building FabricsAlejandro Moreno-Rangel0Tim Sharpe1Gráinne McGill2Filbert Musau3Mackintosh Environmental Architecture Research Unit, The Glasgow School of Art, 167 Renfrew Street, Glasgow G3 6RQ, UKMackintosh Environmental Architecture Research Unit, The Glasgow School of Art, 167 Renfrew Street, Glasgow G3 6RQ, UKMackintosh Environmental Architecture Research Unit, The Glasgow School of Art, 167 Renfrew Street, Glasgow G3 6RQ, UKMackintosh Environmental Architecture Research Unit, The Glasgow School of Art, 167 Renfrew Street, Glasgow G3 6RQ, UKThe ongoing climate change and policies around it are changing how we design and build homes to meet national carbon emission targets. Some countries such as Scotland are adopting higher-energy-efficient buildings as minimum requirements in the building regulations. While net zero homes might be more energy-efficient and emit fewer operational carbon emissions, we have yet to fully understand the influence on the indoor environment, particularly on indoor air quality (IAQ) and thermal comfort. This study compares the IAQ of three homes in Scotland with equal internal layouts and designs but different building fabrics. The homes represent the minimum Scottish building regulations (2015), the Passivhaus standard and the Scottish ‘Gold Standard’. Temperature, relative humidity, PM<sub>2.5</sub> and total volatile organic compounds (tVOC) were measured at five-minute intervals for seven months and compared to occupants’ subjective responses to the IAQ. All three homes had temperatures above the recommended thresholds for overheating. Measured hygrothermal conditions were within the ideal range 66.4% of the time in the Passivhaus, 56.4% in the Gold Standard home and 62.7% in the control home. Measured IAQ was better in homes with higher energy efficiency, particularly tVOC. For instance, indoor PM<sub>2.5</sub> in the Passivhaus were 78.0% of the time below the threshold, while in the standard home the figure was 51.5%, with a weak correlation with outdoor PM<sub>2.5</sub> (Passivhaus: B r<sub>s</sub> = 0.167, K r<sub>s</sub> = 0.306 and L r<sub>s</sub> = 0.163 (<i>p</i> < 0.001); Gold: B r<sub>s</sub> = −0.157, K r<sub>s</sub> = 0.322 and L r<sub>s</sub> = 0.340 (<i>p</i> < 0.001); Control: B r<sub>s</sub> = −0.111, K r<sub>s</sub> = 0.235 and L r<sub>s</sub> = 0.235 (<i>p</i> < 0.001)). TVOCs in the Passivhaus were 81.3%, while in the control home they were 55.0%. While the results cannot be generalised, due to the small sample, this study has significant policy implications, particularly in Scotland, exhibiting the importance of IAQ in current building legislation and sustainable assessment methods.https://www.mdpi.com/2075-5309/13/6/1518net zero policyPassivhausnet zero buildingsindoor air qualitytotal volatile organic compounds (tVOC)particulate matter 25 µm (PM<sub>2.5</sub>)
spellingShingle Alejandro Moreno-Rangel
Tim Sharpe
Gráinne McGill
Filbert Musau
Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
Buildings
net zero policy
Passivhaus
net zero buildings
indoor air quality
total volatile organic compounds (tVOC)
particulate matter 25 µm (PM<sub>2.5</sub>)
title Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
title_full Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
title_fullStr Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
title_full_unstemmed Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
title_short Indoor Air Quality and Thermal Environment Assessment of Scottish Homes with Different Building Fabrics
title_sort indoor air quality and thermal environment assessment of scottish homes with different building fabrics
topic net zero policy
Passivhaus
net zero buildings
indoor air quality
total volatile organic compounds (tVOC)
particulate matter 25 µm (PM<sub>2.5</sub>)
url https://www.mdpi.com/2075-5309/13/6/1518
work_keys_str_mv AT alejandromorenorangel indoorairqualityandthermalenvironmentassessmentofscottishhomeswithdifferentbuildingfabrics
AT timsharpe indoorairqualityandthermalenvironmentassessmentofscottishhomeswithdifferentbuildingfabrics
AT grainnemcgill indoorairqualityandthermalenvironmentassessmentofscottishhomeswithdifferentbuildingfabrics
AT filbertmusau indoorairqualityandthermalenvironmentassessmentofscottishhomeswithdifferentbuildingfabrics