Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva

OBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and n...

Full description

Bibliographic Details
Main Authors: Marcelo Alcantara Holanda, Ricardo Coelho Reis, Georgia Freire Paiva Winkeler, Simone Castelo Branco Fortaleza, José Wellington de Oliveira Lima, Eanes Delgado Barros Pereira
Format: Article
Language:English
Published: Sociedade Brasileira de Pneumologia e Tisiologia 2009-02-01
Series:Jornal Brasileiro de Pneumologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132009000200010
_version_ 1828866792153415680
author Marcelo Alcantara Holanda
Ricardo Coelho Reis
Georgia Freire Paiva Winkeler
Simone Castelo Branco Fortaleza
José Wellington de Oliveira Lima
Eanes Delgado Barros Pereira
author_facet Marcelo Alcantara Holanda
Ricardo Coelho Reis
Georgia Freire Paiva Winkeler
Simone Castelo Branco Fortaleza
José Wellington de Oliveira Lima
Eanes Delgado Barros Pereira
author_sort Marcelo Alcantara Holanda
collection DOAJ
description OBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. METHODS: This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. RESULTS: The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. CONCLUSIONS: The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.<br>OBJETIVO: Falhas da ventilação não-invasiva (VNI) têm sido relacionadas a efeitos adversos agudos do uso de máscaras. O objetivo deste estudo foi comparar a incidência, tipo e intensidade de eventos adversos e conforto das máscaras facial total (MFT), facial (MF) e nasal (MN). MÉTODOS: Estudo randomizado, tipo cruzado, em 24 voluntários sadios submetidos a seis períodos de VNI, modo bilevel positive airway pressure em ajustes de baixa e moderada a alta pressão. Foi aplicado um questionário de avaliação de onze eventos adversos especificamente relacionados ao uso das máscaras. O conforto foi avaliado por escala visual analógica. O CO2 exalado no circuito foi medido entre a conexão da máscara e o orifício de exalação. RESULTADOS: A MFT teve desempenho similar a MF e MN quanto a escores de conforto. A aplicação de pressões mais altas reduziu o conforto e aumentou a incidência e a intensidade dos eventos adversos, independentemente do tipo de máscara. A MFT teve melhor desempenho quanto a vazamentos e dor no nariz e pior resultado quanto ao ressecamento oronasal e claustrofobia. A MF teve o pior resultado quanto a vazamentos. A pressão parcial do CO2 exalado no circuito permaneceu em zero com a MFT. CONCLUSÕES: Os eventos adversos agudos causados pelas interfaces de VNI são relacionados ao tipo de máscara e aos parâmetros de pressão. A MFT é uma alternativa confiável às MF e MN. A reinalação de CO2 a partir do circuito é menos provável de ocorrer com a MFT.
first_indexed 2024-12-13T04:58:24Z
format Article
id doaj.art-c328428264354c079757dd1e414e24a1
institution Directory Open Access Journal
issn 1806-3713
1806-3756
language English
last_indexed 2024-12-13T04:58:24Z
publishDate 2009-02-01
publisher Sociedade Brasileira de Pneumologia e Tisiologia
record_format Article
series Jornal Brasileiro de Pneumologia
spelling doaj.art-c328428264354c079757dd1e414e24a12022-12-21T23:58:51ZengSociedade Brasileira de Pneumologia e TisiologiaJornal Brasileiro de Pneumologia1806-37131806-37562009-02-0135216417310.1590/S1806-37132009000200010Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasivaMarcelo Alcantara HolandaRicardo Coelho ReisGeorgia Freire Paiva WinkelerSimone Castelo Branco FortalezaJosé Wellington de Oliveira LimaEanes Delgado Barros PereiraOBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. METHODS: This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. RESULTS: The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. CONCLUSIONS: The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.<br>OBJETIVO: Falhas da ventilação não-invasiva (VNI) têm sido relacionadas a efeitos adversos agudos do uso de máscaras. O objetivo deste estudo foi comparar a incidência, tipo e intensidade de eventos adversos e conforto das máscaras facial total (MFT), facial (MF) e nasal (MN). MÉTODOS: Estudo randomizado, tipo cruzado, em 24 voluntários sadios submetidos a seis períodos de VNI, modo bilevel positive airway pressure em ajustes de baixa e moderada a alta pressão. Foi aplicado um questionário de avaliação de onze eventos adversos especificamente relacionados ao uso das máscaras. O conforto foi avaliado por escala visual analógica. O CO2 exalado no circuito foi medido entre a conexão da máscara e o orifício de exalação. RESULTADOS: A MFT teve desempenho similar a MF e MN quanto a escores de conforto. A aplicação de pressões mais altas reduziu o conforto e aumentou a incidência e a intensidade dos eventos adversos, independentemente do tipo de máscara. A MFT teve melhor desempenho quanto a vazamentos e dor no nariz e pior resultado quanto ao ressecamento oronasal e claustrofobia. A MF teve o pior resultado quanto a vazamentos. A pressão parcial do CO2 exalado no circuito permaneceu em zero com a MFT. CONCLUSÕES: Os eventos adversos agudos causados pelas interfaces de VNI são relacionados ao tipo de máscara e aos parâmetros de pressão. A MFT é uma alternativa confiável às MF e MN. A reinalação de CO2 a partir do circuito é menos provável de ocorrer com a MFT.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132009000200010Ventilação com pressão positiva intermitenteMáscarasInsuficiência respiratóriaAnálise de falha de equipamentoIntermittent positive-pressure ventilationMasksRespiratory insufficiencyEquipment failure analysis
spellingShingle Marcelo Alcantara Holanda
Ricardo Coelho Reis
Georgia Freire Paiva Winkeler
Simone Castelo Branco Fortaleza
José Wellington de Oliveira Lima
Eanes Delgado Barros Pereira
Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
Jornal Brasileiro de Pneumologia
Ventilação com pressão positiva intermitente
Máscaras
Insuficiência respiratória
Análise de falha de equipamento
Intermittent positive-pressure ventilation
Masks
Respiratory insufficiency
Equipment failure analysis
title Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
title_full Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
title_fullStr Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
title_full_unstemmed Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
title_short Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation Influência das máscaras facial total, facial e nasal nos efeitos adversos agudos durante ventilação não-invasiva
title_sort influence of total face facial and nasal masks on short term adverse effects during noninvasive ventilation influencia das mascaras facial total facial e nasal nos efeitos adversos agudos durante ventilacao nao invasiva
topic Ventilação com pressão positiva intermitente
Máscaras
Insuficiência respiratória
Análise de falha de equipamento
Intermittent positive-pressure ventilation
Masks
Respiratory insufficiency
Equipment failure analysis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132009000200010
work_keys_str_mv AT marceloalcantaraholanda influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva
AT ricardocoelhoreis influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva
AT georgiafreirepaivawinkeler influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva
AT simonecastelobrancofortaleza influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva
AT josewellingtondeoliveiralima influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva
AT eanesdelgadobarrospereira influenceoftotalfacefacialandnasalmasksonshorttermadverseeffectsduringnoninvasiveventilationinfluenciadasmascarasfacialtotalfacialenasalnosefeitosadversosagudosduranteventilacaonaoinvasiva