Indoor radon activity concentration and effective dose rates at schools and thermal spas of Ilgin
Indoor radon activity concentrations and radon doses on the ground floor and basement floor of 19 schools (kindergardens, primary schools, secondary schools, and high schools) and thermal spas of Ilgin district in Konya, have been measured using the AlphaGUARD PQ 2000PRO radon detector, for...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2020-01-01
|
Series: | Nuclear Technology and Radiation Protection |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1451-3994/2020/1451-39942004339E.pdf |
Summary: | Indoor radon activity concentrations and radon doses on the ground floor and
basement floor of 19 schools (kindergardens, primary schools, secondary
schools, and high schools) and thermal spas of Ilgin district in Konya, have
been measured using the AlphaGUARD PQ 2000PRO radon detector, for three days
in the first half of 2016. According to the results, while the indoor radon
concentration for only one location, in total, is above the Turkish action
level of 400 Bqm–3, the values for 10 locations are above the reference
level of 100 Bqm–3, recommended by WHO. The calculated annual effective
doses for inhalation of the radon in indoor air were also found to be 0.26
µSv for the minimum and 4.36 µSv for the maximum. The parametric
distribution analysis is also performed with 3-parameter Weibull
distribution and some remarks are provided on radon concentration activity. |
---|---|
ISSN: | 1451-3994 1452-8185 |