Indoor radon activity concentration and effective dose rates at schools and thermal spas of Ilgin

Indoor radon activity concentrations and radon doses on the ground floor and basement floor of 19 schools (kindergardens, primary schools, secondary schools, and high schools) and thermal spas of Ilgin district in Konya, have been measured using the AlphaGUARD PQ 2000PRO radon detector, for...

Full description

Bibliographic Details
Main Authors: Erdogan Mehmet, Abaka Murat, Manisa Kaan, Bircan Hasan, Kus Coskun, Zedef Veysel
Format: Article
Language:English
Published: VINCA Institute of Nuclear Sciences 2020-01-01
Series:Nuclear Technology and Radiation Protection
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1451-3994/2020/1451-39942004339E.pdf
Description
Summary:Indoor radon activity concentrations and radon doses on the ground floor and basement floor of 19 schools (kindergardens, primary schools, secondary schools, and high schools) and thermal spas of Ilgin district in Konya, have been measured using the AlphaGUARD PQ 2000PRO radon detector, for three days in the first half of 2016. According to the results, while the indoor radon concentration for only one location, in total, is above the Turkish action level of 400 Bqm–3, the values for 10 locations are above the reference level of 100 Bqm–3, recommended by WHO. The calculated annual effective doses for inhalation of the radon in indoor air were also found to be 0.26 µSv for the minimum and 4.36 µSv for the maximum. The parametric distribution analysis is also performed with 3-parameter Weibull distribution and some remarks are provided on radon concentration activity.
ISSN:1451-3994
1452-8185