Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography

Background: For vertebroplasty, newly synthesized bone cements are proposed to replace traditional polymethylmethacrylate (PMMA). Most inventors initially evaluated these newly developed cements in animal spine models. However, even these time- and work-consuming histological inspections performed m...

Full description

Bibliographic Details
Main Authors: Chi-Ching Yeh, Chii-Jen Chen, Yun Tang, Kai-Chiang Yang, Chang-Chin Wu
Format: Article
Language:English
Published: Wolters Kluwer Health/LWW 2019-01-01
Series:Formosan Journal of Surgery
Subjects:
Online Access:http://www.e-fjs.org/article.asp?issn=1682-606X;year=2019;volume=52;issue=2;spage=45;epage=51;aulast=Yeh
_version_ 1797704619318575104
author Chi-Ching Yeh
Chii-Jen Chen
Yun Tang
Kai-Chiang Yang
Chang-Chin Wu
author_facet Chi-Ching Yeh
Chii-Jen Chen
Yun Tang
Kai-Chiang Yang
Chang-Chin Wu
author_sort Chi-Ching Yeh
collection DOAJ
description Background: For vertebroplasty, newly synthesized bone cements are proposed to replace traditional polymethylmethacrylate (PMMA). Most inventors initially evaluated these newly developed cements in animal spine models. However, even these time- and work-consuming histological inspections performed meticulously by experienced hands, there are still lots of specimen lost during the processing procedures. Although the histological sections can reveal new bone formations and surrounding tissue reactions to implanted materials, it is difficult to identify the degradation processes of the injected cement. In fact, there is no standard method to quantify the volume changes of injected substitutes postoperation. Methods: Previously, we developed two new biodegradable cements and evaluated performances in fixed-volume and fixed-shaped holes in vertebral bodies of porcine lumbar spine. The animals were sacrificed and the retrieved spines were analyzed after 3 and 6 months. Herein, we further used computed tomography (CT) and three-dimensional CT (3D-CT) to quantitate volumes and biodegradation of cements inside vertebral bodies after previous attestation of CT findings. Exteriors of controls and injected materials were reconstructed with different Hounsfield units (HU); changes of HU as well as cement volumes were later calculated. Results: The results revealed that the volumes and shapes of these biodegradable cements can be determined by 3D-CT. After meticulous comparisons among gross specimens, histologies, and CT images, the different patterns observed in CT implied consistency among all three observations. Gradual reductions of HU and volumes of newly synthesized cements showed the degradability. Meanwhile, consistent HU and volumes of PMMA meant its inertness. Conclusion: CT imaging may be a preliminary, quantitative, and liable way for evaluating injectable bone cements in the vertebral bodies.
first_indexed 2024-03-12T05:23:06Z
format Article
id doaj.art-c379ab4aac844a00ba688bbdaeb01f6a
institution Directory Open Access Journal
issn 1682-606X
language English
last_indexed 2024-03-12T05:23:06Z
publishDate 2019-01-01
publisher Wolters Kluwer Health/LWW
record_format Article
series Formosan Journal of Surgery
spelling doaj.art-c379ab4aac844a00ba688bbdaeb01f6a2023-09-03T07:33:15ZengWolters Kluwer Health/LWWFormosan Journal of Surgery1682-606X2019-01-01522455110.4103/fjs.fjs_60_18Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomographyChi-Ching YehChii-Jen ChenYun TangKai-Chiang YangChang-Chin WuBackground: For vertebroplasty, newly synthesized bone cements are proposed to replace traditional polymethylmethacrylate (PMMA). Most inventors initially evaluated these newly developed cements in animal spine models. However, even these time- and work-consuming histological inspections performed meticulously by experienced hands, there are still lots of specimen lost during the processing procedures. Although the histological sections can reveal new bone formations and surrounding tissue reactions to implanted materials, it is difficult to identify the degradation processes of the injected cement. In fact, there is no standard method to quantify the volume changes of injected substitutes postoperation. Methods: Previously, we developed two new biodegradable cements and evaluated performances in fixed-volume and fixed-shaped holes in vertebral bodies of porcine lumbar spine. The animals were sacrificed and the retrieved spines were analyzed after 3 and 6 months. Herein, we further used computed tomography (CT) and three-dimensional CT (3D-CT) to quantitate volumes and biodegradation of cements inside vertebral bodies after previous attestation of CT findings. Exteriors of controls and injected materials were reconstructed with different Hounsfield units (HU); changes of HU as well as cement volumes were later calculated. Results: The results revealed that the volumes and shapes of these biodegradable cements can be determined by 3D-CT. After meticulous comparisons among gross specimens, histologies, and CT images, the different patterns observed in CT implied consistency among all three observations. Gradual reductions of HU and volumes of newly synthesized cements showed the degradability. Meanwhile, consistent HU and volumes of PMMA meant its inertness. Conclusion: CT imaging may be a preliminary, quantitative, and liable way for evaluating injectable bone cements in the vertebral bodies.http://www.e-fjs.org/article.asp?issn=1682-606X;year=2019;volume=52;issue=2;spage=45;epage=51;aulast=YehComposite bone cementvertebroplasty
spellingShingle Chi-Ching Yeh
Chii-Jen Chen
Yun Tang
Kai-Chiang Yang
Chang-Chin Wu
Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
Formosan Journal of Surgery
Composite bone cement
vertebroplasty
title Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
title_full Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
title_fullStr Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
title_full_unstemmed Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
title_short Biodegradation patterns of injected composite bone cements in porcine vertebral bodies: A study using quantitative computed tomography
title_sort biodegradation patterns of injected composite bone cements in porcine vertebral bodies a study using quantitative computed tomography
topic Composite bone cement
vertebroplasty
url http://www.e-fjs.org/article.asp?issn=1682-606X;year=2019;volume=52;issue=2;spage=45;epage=51;aulast=Yeh
work_keys_str_mv AT chichingyeh biodegradationpatternsofinjectedcompositebonecementsinporcinevertebralbodiesastudyusingquantitativecomputedtomography
AT chiijenchen biodegradationpatternsofinjectedcompositebonecementsinporcinevertebralbodiesastudyusingquantitativecomputedtomography
AT yuntang biodegradationpatternsofinjectedcompositebonecementsinporcinevertebralbodiesastudyusingquantitativecomputedtomography
AT kaichiangyang biodegradationpatternsofinjectedcompositebonecementsinporcinevertebralbodiesastudyusingquantitativecomputedtomography
AT changchinwu biodegradationpatternsofinjectedcompositebonecementsinporcinevertebralbodiesastudyusingquantitativecomputedtomography