Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
To achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influ...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis Group
2023-09-01
|
Series: | Journal of Asian Architecture and Building Engineering |
Subjects: | |
Online Access: | http://dx.doi.org/10.1080/13467581.2022.2160211 |
_version_ | 1827065882786922496 |
---|---|
author | Minseok Kim Youngsun Kim Jieun Cha Gyu Bin Han Jihyeon Park |
author_facet | Minseok Kim Youngsun Kim Jieun Cha Gyu Bin Han Jihyeon Park |
author_sort | Minseok Kim |
collection | DOAJ |
description | To achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influencing the evacuation efficiency can be controlled owing to the underground location of all floors. Therefore, all evacuees followed the same evacuation direction. Comprehensively, a spatial analysis methodology(Cellular ECEM) was employed to derive the evacuation costs through the sum of visibility cost and distance cost. Subsequently, the evacuation costs were compared in all cases to review the hindrances in evacuation according to the type and area ratio of the planned floor opening, and several causes of evacuation cost deviations were discussed. Overall, increasing the area of the floor opening deteriorates the evacuation efficiency. The evacuation efficiency increased if the area of the floor opening is appropriately separated and a bridge is constructed in the middle to connect a path. Furthermore, following the longer path around the floor opening to use the main vertical means of circulation, owing to the connection between the atrium and floor opening, is more vulnerable toward evacuation efficiency than other floor opening types. |
first_indexed | 2024-03-11T16:26:32Z |
format | Article |
id | doaj.art-c3ab934975ba42979143f640ddbdedf7 |
institution | Directory Open Access Journal |
issn | 1347-2852 |
language | English |
last_indexed | 2025-03-19T23:10:06Z |
publishDate | 2023-09-01 |
publisher | Taylor & Francis Group |
record_format | Article |
series | Journal of Asian Architecture and Building Engineering |
spelling | doaj.art-c3ab934975ba42979143f640ddbdedf72024-10-15T14:56:50ZengTaylor & Francis GroupJournal of Asian Architecture and Building Engineering1347-28522023-09-012252581259510.1080/13467581.2022.21602112160211Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, KoreaMinseok Kim0Youngsun Kim1Jieun Cha2Gyu Bin Han3Jihyeon Park4Pukyong National UniversityPukyong National UniversitySeoul National UniversitySeoul National UniversitySeoul National UniversityTo achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influencing the evacuation efficiency can be controlled owing to the underground location of all floors. Therefore, all evacuees followed the same evacuation direction. Comprehensively, a spatial analysis methodology(Cellular ECEM) was employed to derive the evacuation costs through the sum of visibility cost and distance cost. Subsequently, the evacuation costs were compared in all cases to review the hindrances in evacuation according to the type and area ratio of the planned floor opening, and several causes of evacuation cost deviations were discussed. Overall, increasing the area of the floor opening deteriorates the evacuation efficiency. The evacuation efficiency increased if the area of the floor opening is appropriately separated and a bridge is constructed in the middle to connect a path. Furthermore, following the longer path around the floor opening to use the main vertical means of circulation, owing to the connection between the atrium and floor opening, is more vulnerable toward evacuation efficiency than other floor opening types.http://dx.doi.org/10.1080/13467581.2022.2160211openingvoidatriummultipurpose commercial buildingevacuation cost evaluation methodologyevacuation |
spellingShingle | Minseok Kim Youngsun Kim Jieun Cha Gyu Bin Han Jihyeon Park Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea Journal of Asian Architecture and Building Engineering opening void atrium multipurpose commercial building evacuation cost evaluation methodology evacuation |
title | Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea |
title_full | Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea |
title_fullStr | Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea |
title_full_unstemmed | Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea |
title_short | Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea |
title_sort | effect of floor openings on evacuation efficiency in multipurpose commercial buildings ifc mall in yeouido seoul korea |
topic | opening void atrium multipurpose commercial building evacuation cost evaluation methodology evacuation |
url | http://dx.doi.org/10.1080/13467581.2022.2160211 |
work_keys_str_mv | AT minseokkim effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea AT youngsunkim effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea AT jieuncha effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea AT gyubinhan effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea AT jihyeonpark effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea |