Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea

To achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influ...

Full description

Bibliographic Details
Main Authors: Minseok Kim, Youngsun Kim, Jieun Cha, Gyu Bin Han, Jihyeon Park
Format: Article
Language:English
Published: Taylor & Francis Group 2023-09-01
Series:Journal of Asian Architecture and Building Engineering
Subjects:
Online Access:http://dx.doi.org/10.1080/13467581.2022.2160211
_version_ 1827065882786922496
author Minseok Kim
Youngsun Kim
Jieun Cha
Gyu Bin Han
Jihyeon Park
author_facet Minseok Kim
Youngsun Kim
Jieun Cha
Gyu Bin Han
Jihyeon Park
author_sort Minseok Kim
collection DOAJ
description To achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influencing the evacuation efficiency can be controlled owing to the underground location of all floors. Therefore, all evacuees followed the same evacuation direction. Comprehensively, a spatial analysis methodology(Cellular ECEM) was employed to derive the evacuation costs through the sum of visibility cost and distance cost. Subsequently, the evacuation costs were compared in all cases to review the hindrances in evacuation according to the type and area ratio of the planned floor opening, and several causes of evacuation cost deviations were discussed. Overall, increasing the area of the floor opening deteriorates the evacuation efficiency. The evacuation efficiency increased if the area of the floor opening is appropriately separated and a bridge is constructed in the middle to connect a path. Furthermore, following the longer path around the floor opening to use the main vertical means of circulation, owing to the connection between the atrium and floor opening, is more vulnerable toward evacuation efficiency than other floor opening types.
first_indexed 2024-03-11T16:26:32Z
format Article
id doaj.art-c3ab934975ba42979143f640ddbdedf7
institution Directory Open Access Journal
issn 1347-2852
language English
last_indexed 2025-03-19T23:10:06Z
publishDate 2023-09-01
publisher Taylor & Francis Group
record_format Article
series Journal of Asian Architecture and Building Engineering
spelling doaj.art-c3ab934975ba42979143f640ddbdedf72024-10-15T14:56:50ZengTaylor & Francis GroupJournal of Asian Architecture and Building Engineering1347-28522023-09-012252581259510.1080/13467581.2022.21602112160211Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, KoreaMinseok Kim0Youngsun Kim1Jieun Cha2Gyu Bin Han3Jihyeon Park4Pukyong National UniversityPukyong National UniversitySeoul National UniversitySeoul National UniversitySeoul National UniversityTo achieve evacuation-optimized design at the architectural planning phase, this study analyzed the effect of floor openings in multipurpose commercial buildings on their evacuation efficiency. Herein, the IFC Mall in Yeouido, Seoul, Korea was considered the study site, because all the factors influencing the evacuation efficiency can be controlled owing to the underground location of all floors. Therefore, all evacuees followed the same evacuation direction. Comprehensively, a spatial analysis methodology(Cellular ECEM) was employed to derive the evacuation costs through the sum of visibility cost and distance cost. Subsequently, the evacuation costs were compared in all cases to review the hindrances in evacuation according to the type and area ratio of the planned floor opening, and several causes of evacuation cost deviations were discussed. Overall, increasing the area of the floor opening deteriorates the evacuation efficiency. The evacuation efficiency increased if the area of the floor opening is appropriately separated and a bridge is constructed in the middle to connect a path. Furthermore, following the longer path around the floor opening to use the main vertical means of circulation, owing to the connection between the atrium and floor opening, is more vulnerable toward evacuation efficiency than other floor opening types.http://dx.doi.org/10.1080/13467581.2022.2160211openingvoidatriummultipurpose commercial buildingevacuation cost evaluation methodologyevacuation
spellingShingle Minseok Kim
Youngsun Kim
Jieun Cha
Gyu Bin Han
Jihyeon Park
Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
Journal of Asian Architecture and Building Engineering
opening
void
atrium
multipurpose commercial building
evacuation cost evaluation methodology
evacuation
title Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
title_full Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
title_fullStr Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
title_full_unstemmed Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
title_short Effect of floor openings on evacuation efficiency in multipurpose commercial buildings: IFC mall in Yeouido, Seoul, Korea
title_sort effect of floor openings on evacuation efficiency in multipurpose commercial buildings ifc mall in yeouido seoul korea
topic opening
void
atrium
multipurpose commercial building
evacuation cost evaluation methodology
evacuation
url http://dx.doi.org/10.1080/13467581.2022.2160211
work_keys_str_mv AT minseokkim effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea
AT youngsunkim effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea
AT jieuncha effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea
AT gyubinhan effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea
AT jihyeonpark effectofflooropeningsonevacuationefficiencyinmultipurposecommercialbuildingsifcmallinyeouidoseoulkorea