Data for a pre-performance test of self-developed electronic tongue sensors
This article presents data, which can be applied for a pre-performance test of self-developed electronic tongue sensors. Contained data is related to the research article “Impact of Sodium Lauryl Sulfate in oral liquids on E-Tongue Measurements” (http://dx.doi.org/10.1016/j.ijpharm.2016.10.045; (L.I...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2016-12-01
|
Series: | Data in Brief |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352340916307016 |
_version_ | 1828750976440336384 |
---|---|
author | Laura Isabell Immohr Roy Turner Miriam Pein-Hackelbusch |
author_facet | Laura Isabell Immohr Roy Turner Miriam Pein-Hackelbusch |
author_sort | Laura Isabell Immohr |
collection | DOAJ |
description | This article presents data, which can be applied for a pre-performance test of self-developed electronic tongue sensors. Contained data is related to the research article “Impact of Sodium Lauryl Sulfate in oral liquids on E-Tongue Measurements” (http://dx.doi.org/10.1016/j.ijpharm.2016.10.045; (L.I. Immohr, R. Turner, M. Pein-Hackelbusch, 2016) [1]). Sensor responses were obtained from 10 subsequent measurements and four different concentrations of quinine hydrochloride by electronic tongue (TS-5000Z, Insent Inc., Atsugi-Shi, Japan) measurements. Based on the data for the pre-performance testing, which were calculated based on the fluctuation range of the sensor responses around the median, stability criteria and required preconditions cycles were defined. |
first_indexed | 2024-12-10T20:47:34Z |
format | Article |
id | doaj.art-c3d3d1d87e48481d9e02f644d693e172 |
institution | Directory Open Access Journal |
issn | 2352-3409 |
language | English |
last_indexed | 2024-12-10T20:47:34Z |
publishDate | 2016-12-01 |
publisher | Elsevier |
record_format | Article |
series | Data in Brief |
spelling | doaj.art-c3d3d1d87e48481d9e02f644d693e1722022-12-22T01:34:12ZengElsevierData in Brief2352-34092016-12-019C1090109310.1016/j.dib.2016.11.041Data for a pre-performance test of self-developed electronic tongue sensorsLaura Isabell Immohr0Roy Turner1Miriam Pein-Hackelbusch2Heinrich-Heine-University Duesseldorf, Institute of Pharmaceutics and Biopharmaceutics, Universitaetsstrasse 1, 40225 Duesseldorf, GermanyNovartis Pharma AG, Technical Research & Development, 4056 Basel, SwitzerlandHeinrich-Heine-University Duesseldorf, Institute of Pharmaceutics and Biopharmaceutics, Universitaetsstrasse 1, 40225 Duesseldorf, GermanyThis article presents data, which can be applied for a pre-performance test of self-developed electronic tongue sensors. Contained data is related to the research article “Impact of Sodium Lauryl Sulfate in oral liquids on E-Tongue Measurements” (http://dx.doi.org/10.1016/j.ijpharm.2016.10.045; (L.I. Immohr, R. Turner, M. Pein-Hackelbusch, 2016) [1]). Sensor responses were obtained from 10 subsequent measurements and four different concentrations of quinine hydrochloride by electronic tongue (TS-5000Z, Insent Inc., Atsugi-Shi, Japan) measurements. Based on the data for the pre-performance testing, which were calculated based on the fluctuation range of the sensor responses around the median, stability criteria and required preconditions cycles were defined.http://www.sciencedirect.com/science/article/pii/S2352340916307016e-tonguePerformance testingConditioning cycles |
spellingShingle | Laura Isabell Immohr Roy Turner Miriam Pein-Hackelbusch Data for a pre-performance test of self-developed electronic tongue sensors Data in Brief e-tongue Performance testing Conditioning cycles |
title | Data for a pre-performance test of self-developed electronic tongue sensors |
title_full | Data for a pre-performance test of self-developed electronic tongue sensors |
title_fullStr | Data for a pre-performance test of self-developed electronic tongue sensors |
title_full_unstemmed | Data for a pre-performance test of self-developed electronic tongue sensors |
title_short | Data for a pre-performance test of self-developed electronic tongue sensors |
title_sort | data for a pre performance test of self developed electronic tongue sensors |
topic | e-tongue Performance testing Conditioning cycles |
url | http://www.sciencedirect.com/science/article/pii/S2352340916307016 |
work_keys_str_mv | AT lauraisabellimmohr dataforapreperformancetestofselfdevelopedelectronictonguesensors AT royturner dataforapreperformancetestofselfdevelopedelectronictonguesensors AT miriampeinhackelbusch dataforapreperformancetestofselfdevelopedelectronictonguesensors |