Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study

Abstract Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents....

Full description

Bibliographic Details
Main Authors: Yoko Usami, Mitsutoshi Sugano, Takeshi Uehara, Masayoshi Koinuma, Nau Ishimine, Kenji Kawasaki, Kazuyoshi Yamauchi, Hideaki Hamano, Takayuki Honda
Format: Article
Language:English
Published: Nature Portfolio 2021-03-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-86024-5
_version_ 1818432357324029952
author Yoko Usami
Mitsutoshi Sugano
Takeshi Uehara
Masayoshi Koinuma
Nau Ishimine
Kenji Kawasaki
Kazuyoshi Yamauchi
Hideaki Hamano
Takayuki Honda
author_facet Yoko Usami
Mitsutoshi Sugano
Takeshi Uehara
Masayoshi Koinuma
Nau Ishimine
Kenji Kawasaki
Kazuyoshi Yamauchi
Hideaki Hamano
Takayuki Honda
author_sort Yoko Usami
collection DOAJ
description Abstract Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents. This study enrolled 466 IgG4-RD and non-IgG4-RD patients who required measurement of serum IgG4 levels to diagnose or treat IgG4-RD. Serum IgG4 was measured using three reagents: N-assay LA IgG4 Nittobo (Nittobo), BS-NIA IgG4 (TBS), and N Latex IgG4 (Siemens). The values obtained using the three reagents were compared, and cut-off values were calculated for each. Although there was good correlation among the results with the three reagents, the measured and cut-off values were all different. The Nittobo values were 1.4 times the TBS values and the TBS values were almost half those of the Siemens values. ROC curve analysis showed cut-off values for the Nittobo, TBS, and Siemens reagents of 1.42, 1.31, and 2.38 g/L, respectively. The measured and cut-off values of serum IgG4 vary depending on the reagents used for the assay, although there is good correlation among the values measured by the three reagents.
first_indexed 2024-12-14T16:03:55Z
format Article
id doaj.art-c3d99f3a5cb94f7faf69d081f1d61627
institution Directory Open Access Journal
issn 2045-2322
language English
last_indexed 2024-12-14T16:03:55Z
publishDate 2021-03-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj.art-c3d99f3a5cb94f7faf69d081f1d616272022-12-21T22:55:08ZengNature PortfolioScientific Reports2045-23222021-03-011111710.1038/s41598-021-86024-5Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter studyYoko Usami0Mitsutoshi Sugano1Takeshi Uehara2Masayoshi Koinuma3Nau Ishimine4Kenji Kawasaki5Kazuyoshi Yamauchi6Hideaki Hamano7Takayuki Honda8Department of Laboratory Medicine, Shinshu University HospitalDepartment of Laboratory Medicine, Shinshu University HospitalDepartment of Laboratory Medicine, Shinshu University HospitalFaculty of Pharmaceutical Sciences, Teikyo Heisei UniversityDepartment of Laboratory Medicine, Shinshu University HospitalDepartment of Laboratory Medicine, Chiba University School of MedicineDepartment of Laboratory Medicine, Faculty of Medicine, University of TsukubaNagano Prefectural Kiso HospitalDepartment of Laboratory Medicine, Shinshu University HospitalAbstract Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents. This study enrolled 466 IgG4-RD and non-IgG4-RD patients who required measurement of serum IgG4 levels to diagnose or treat IgG4-RD. Serum IgG4 was measured using three reagents: N-assay LA IgG4 Nittobo (Nittobo), BS-NIA IgG4 (TBS), and N Latex IgG4 (Siemens). The values obtained using the three reagents were compared, and cut-off values were calculated for each. Although there was good correlation among the results with the three reagents, the measured and cut-off values were all different. The Nittobo values were 1.4 times the TBS values and the TBS values were almost half those of the Siemens values. ROC curve analysis showed cut-off values for the Nittobo, TBS, and Siemens reagents of 1.42, 1.31, and 2.38 g/L, respectively. The measured and cut-off values of serum IgG4 vary depending on the reagents used for the assay, although there is good correlation among the values measured by the three reagents.https://doi.org/10.1038/s41598-021-86024-5
spellingShingle Yoko Usami
Mitsutoshi Sugano
Takeshi Uehara
Masayoshi Koinuma
Nau Ishimine
Kenji Kawasaki
Kazuyoshi Yamauchi
Hideaki Hamano
Takayuki Honda
Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
Scientific Reports
title Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
title_full Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
title_fullStr Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
title_full_unstemmed Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
title_short Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
title_sort cut off values of serum igg4 among three reagents including a novel igg4 reagent a multicenter study
url https://doi.org/10.1038/s41598-021-86024-5
work_keys_str_mv AT yokousami cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT mitsutoshisugano cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT takeshiuehara cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT masayoshikoinuma cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT nauishimine cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT kenjikawasaki cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT kazuyoshiyamauchi cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT hideakihamano cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy
AT takayukihonda cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy