The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study...

Full description

Bibliographic Details
Main Authors: Sahar Toluee Achacheluee, Leila Rahnama, Nouredin Karimi, Iraj Abdollahi, Shapour Jaberzadeh, Syed Asadullah Arslan
Format: Article
Language:English
Published: Negah Institute for Scientific Communication 2016-01-01
Series:Physical Treatments
Subjects:
Online Access:http://ptj.uswr.ac.ir/article-1-274-en.html
_version_ 1819105935576006656
author Sahar Toluee Achacheluee
Leila Rahnama
Nouredin Karimi
Iraj Abdollahi
Shapour Jaberzadeh
Syed Asadullah Arslan
author_facet Sahar Toluee Achacheluee
Leila Rahnama
Nouredin Karimi
Iraj Abdollahi
Shapour Jaberzadeh
Syed Asadullah Arslan
author_sort Sahar Toluee Achacheluee
collection DOAJ
description Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these two tests. Methods: A total of 15 patients with subacute stroke (54-76 years old) participated in this study. They were selected non-randomly from rehabilitation clinics and hospitals of Tehran, Iran, based on inclusive and exclusive criteria. Intraclass correlation coefficient (ICC), standard error measurement (SEM), and MDC were used for investigating intraday and interday reliability for 1 hour and 3 days. Results: Intraday reliabilities of Fugl-Meyer and 9-hole pegboard were excellent with ICC of 0.98 and 0.98, also MDC of 1.96 and 8.59, respectively. The interday reliabilities of these tests were also excellent with ICC of 0.99 and 0.96, as well as MDC of 1.52 and 12.69, respectively. The absolute reliability (SEM) was less than 10% of maximum acquired scores indicating acceptable errors of measurement. Conclusion: Results show that the Fugl-Meyer assessment and 9-hole pegboard test have excellent test-retest reliability. Therefore these tests can be used for appropriate treatment planning and clinical decision making in patients with subacute stroke
first_indexed 2024-12-22T02:30:09Z
format Article
id doaj.art-c3eb64121afd4677ba290502a642b392
institution Directory Open Access Journal
issn 2423-5830
language English
last_indexed 2024-12-22T02:30:09Z
publishDate 2016-01-01
publisher Negah Institute for Scientific Communication
record_format Article
series Physical Treatments
spelling doaj.art-c3eb64121afd4677ba290502a642b3922022-12-21T18:41:54ZengNegah Institute for Scientific CommunicationPhysical Treatments2423-58302016-01-0154225230The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute StrokeSahar Toluee Achacheluee0Leila Rahnama1Nouredin Karimi2Iraj Abdollahi3Shapour Jaberzadeh4Syed Asadullah Arslan5 Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. Department of Physical Therapy, Faculty of Medicine, Monash University, Melbourne, Australia. Department of Physiotherapy, School of Rehabilitation, International Campus, Tehran University of Medical Sciences, Tehran, Iran. Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these two tests. Methods: A total of 15 patients with subacute stroke (54-76 years old) participated in this study. They were selected non-randomly from rehabilitation clinics and hospitals of Tehran, Iran, based on inclusive and exclusive criteria. Intraclass correlation coefficient (ICC), standard error measurement (SEM), and MDC were used for investigating intraday and interday reliability for 1 hour and 3 days. Results: Intraday reliabilities of Fugl-Meyer and 9-hole pegboard were excellent with ICC of 0.98 and 0.98, also MDC of 1.96 and 8.59, respectively. The interday reliabilities of these tests were also excellent with ICC of 0.99 and 0.96, as well as MDC of 1.52 and 12.69, respectively. The absolute reliability (SEM) was less than 10% of maximum acquired scores indicating acceptable errors of measurement. Conclusion: Results show that the Fugl-Meyer assessment and 9-hole pegboard test have excellent test-retest reliability. Therefore these tests can be used for appropriate treatment planning and clinical decision making in patients with subacute strokehttp://ptj.uswr.ac.ir/article-1-274-en.htmlstrokereliabilityfugl-meyer9-hole pegboardtest-retest
spellingShingle Sahar Toluee Achacheluee
Leila Rahnama
Nouredin Karimi
Iraj Abdollahi
Shapour Jaberzadeh
Syed Asadullah Arslan
The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
Physical Treatments
stroke
reliability
fugl-meyer
9-hole pegboard
test-retest
title The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
title_full The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
title_fullStr The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
title_full_unstemmed The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
title_short The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
title_sort test retest reliability and minimal detectable change of the fugl meyer assessment of the upper extremity and 9 hole pegboard test in individuals with subacute stroke
topic stroke
reliability
fugl-meyer
9-hole pegboard
test-retest
url http://ptj.uswr.ac.ir/article-1-274-en.html
work_keys_str_mv AT sahartolueeachacheluee thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT leilarahnama thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT nouredinkarimi thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT irajabdollahi thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT shapourjaberzadeh thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT syedasadullaharslan thetestretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT sahartolueeachacheluee testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT leilarahnama testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT nouredinkarimi testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT irajabdollahi testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT shapourjaberzadeh testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke
AT syedasadullaharslan testretestreliabilityandminimaldetectablechangeofthefuglmeyerassessmentoftheupperextremityand9holepegboardtestinindividualswithsubacutestroke