A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology
In this paper, a new fast and accurate method for fault detection, location, and classification on multi-terminal DC (MTDC) distribution networks connected to renewable energy and energy storages presented. MTDC networks develop due to some issues such as DC resources and loads expanding, and try to...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Iran University of Science and Technology
2020-06-01
|
Series: | Iranian Journal of Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://ijeee.iust.ac.ir/article-1-1488-en.html |
_version_ | 1818245298042961920 |
---|---|
author | M. Dodangeh N. Ghaffarzadeh |
author_facet | M. Dodangeh N. Ghaffarzadeh |
author_sort | M. Dodangeh |
collection | DOAJ |
description | In this paper, a new fast and accurate method for fault detection, location, and classification on multi-terminal DC (MTDC) distribution networks connected to renewable energy and energy storages presented. MTDC networks develop due to some issues such as DC resources and loads expanding, and try to the power quality increasing. It is important to recognize the fault type and location in order to continue service and prevent further damages. In this method, a circuit kit is connected to the network. Fault detection is performed with the measurement of the current of the connected kits and the traveling-waves of the derivative of the fault current and applying to a mathematical morphology filter, in the Fault time. The type and location of faults determinate using circuit equations and current calculations. DC series and ground arc faults are considered as DC distribution network disturbances. The presented method was tested in an MTDC network with many faults. The results illustrate the validity of the proposed method. The main advantages of the proposed fault location and classification strategy are higher accuracy and speed than conventional approaches. This method robustly operates to changing in sampling frequency, fault resistance, and works very well in high impedance fault. |
first_indexed | 2024-12-12T14:30:41Z |
format | Article |
id | doaj.art-c40eefbfa29f416ca6336350a3d45e42 |
institution | Directory Open Access Journal |
issn | 1735-2827 2383-3890 |
language | English |
last_indexed | 2024-12-12T14:30:41Z |
publishDate | 2020-06-01 |
publisher | Iran University of Science and Technology |
record_format | Article |
series | Iranian Journal of Electrical and Electronic Engineering |
spelling | doaj.art-c40eefbfa29f416ca6336350a3d45e422022-12-22T00:21:32ZengIran University of Science and TechnologyIranian Journal of Electrical and Electronic Engineering1735-28272383-38902020-06-01162248258A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical MorphologyM. Dodangeh0N. Ghaffarzadeh1 Department of Electrical Engineering, Imam Khomeini International University, Qazvin 3414896818, Iran. Department of Electrical Engineering, Imam Khomeini International University, Qazvin 3414896818, Iran. In this paper, a new fast and accurate method for fault detection, location, and classification on multi-terminal DC (MTDC) distribution networks connected to renewable energy and energy storages presented. MTDC networks develop due to some issues such as DC resources and loads expanding, and try to the power quality increasing. It is important to recognize the fault type and location in order to continue service and prevent further damages. In this method, a circuit kit is connected to the network. Fault detection is performed with the measurement of the current of the connected kits and the traveling-waves of the derivative of the fault current and applying to a mathematical morphology filter, in the Fault time. The type and location of faults determinate using circuit equations and current calculations. DC series and ground arc faults are considered as DC distribution network disturbances. The presented method was tested in an MTDC network with many faults. The results illustrate the validity of the proposed method. The main advantages of the proposed fault location and classification strategy are higher accuracy and speed than conventional approaches. This method robustly operates to changing in sampling frequency, fault resistance, and works very well in high impedance fault.http://ijeee.iust.ac.ir/article-1-1488-en.htmlmtdcfault detection and classificationmathematical morphologycurrent injection kitonline wavelet. |
spellingShingle | M. Dodangeh N. Ghaffarzadeh A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology Iranian Journal of Electrical and Electronic Engineering mtdc fault detection and classification mathematical morphology current injection kit online wavelet. |
title | A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology |
title_full | A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology |
title_fullStr | A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology |
title_full_unstemmed | A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology |
title_short | A New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology |
title_sort | new fast and accurate fault location and classification method on mtdc microgrids using current injection technique traveling waves online wavelet and mathematical morphology |
topic | mtdc fault detection and classification mathematical morphology current injection kit online wavelet. |
url | http://ijeee.iust.ac.ir/article-1-1488-en.html |
work_keys_str_mv | AT mdodangeh anewfastandaccuratefaultlocationandclassificationmethodonmtdcmicrogridsusingcurrentinjectiontechniquetravelingwavesonlinewaveletandmathematicalmorphology AT nghaffarzadeh anewfastandaccuratefaultlocationandclassificationmethodonmtdcmicrogridsusingcurrentinjectiontechniquetravelingwavesonlinewaveletandmathematicalmorphology AT mdodangeh newfastandaccuratefaultlocationandclassificationmethodonmtdcmicrogridsusingcurrentinjectiontechniquetravelingwavesonlinewaveletandmathematicalmorphology AT nghaffarzadeh newfastandaccuratefaultlocationandclassificationmethodonmtdcmicrogridsusingcurrentinjectiontechniquetravelingwavesonlinewaveletandmathematicalmorphology |