Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames

Background: Identifying End-Diastole (ED) and End-Systole (ES) frames is highly important in the process of evaluating cardiac function and measuring global parameters accurately, such as Ejection Fraction (EF), Cardiac Output (CO) and Stroke Volume. Objectives: The current study aimed to develop a...

Full description

Bibliographic Details
Main Authors: Saeed Darvishi, Hamid Behnam, Majid Pouladian, Niloufar Samiei
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2013-01-01
Series:Research in Cardiovascular Medicine
Subjects:
Online Access:http://www.rcvmonline.com/article.asp?issn=2251-9572;year=2013;volume=2;issue=1;spage=39;epage=45;aulast=Darvishi;type=0
_version_ 1818855081745842176
author Saeed Darvishi
Hamid Behnam
Majid Pouladian
Niloufar Samiei
author_facet Saeed Darvishi
Hamid Behnam
Majid Pouladian
Niloufar Samiei
author_sort Saeed Darvishi
collection DOAJ
description Background: Identifying End-Diastole (ED) and End-Systole (ES) frames is highly important in the process of evaluating cardiac function and measuring global parameters accurately, such as Ejection Fraction (EF), Cardiac Output (CO) and Stroke Volume. Objectives: The current study aimed to develop a new method based on measuring volume changes in Left Ventricle (LV) during cardiac cycle. Material and Methods: For this purpose, the Level Set method was used both in detecting endocardium border and quantifying cardiac function of all frames. Results: Demonstrating LV volumes displays ED and ES frames and the volumes used in calculating the required parameters. Conclusions: Since ES and ED frames exist in iso-volumic phases of the cardiac cycle with minimum and maximum values of LV volume signals, such peaks can be utilized in finding related frames.
first_indexed 2024-12-19T08:02:56Z
format Article
id doaj.art-c427f1aa020649a9a7e90ef6410f91f5
institution Directory Open Access Journal
issn 2251-9572
2251-9580
language English
last_indexed 2024-12-19T08:02:56Z
publishDate 2013-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Research in Cardiovascular Medicine
spelling doaj.art-c427f1aa020649a9a7e90ef6410f91f52022-12-21T20:29:49ZengWolters Kluwer Medknow PublicationsResearch in Cardiovascular Medicine2251-95722251-95802013-01-0121394510.5812/cardiovascmed.6397Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole framesSaeed DarvishiHamid BehnamMajid PouladianNiloufar SamieiBackground: Identifying End-Diastole (ED) and End-Systole (ES) frames is highly important in the process of evaluating cardiac function and measuring global parameters accurately, such as Ejection Fraction (EF), Cardiac Output (CO) and Stroke Volume. Objectives: The current study aimed to develop a new method based on measuring volume changes in Left Ventricle (LV) during cardiac cycle. Material and Methods: For this purpose, the Level Set method was used both in detecting endocardium border and quantifying cardiac function of all frames. Results: Demonstrating LV volumes displays ED and ES frames and the volumes used in calculating the required parameters. Conclusions: Since ES and ED frames exist in iso-volumic phases of the cardiac cycle with minimum and maximum values of LV volume signals, such peaks can be utilized in finding related frames.http://www.rcvmonline.com/article.asp?issn=2251-9572;year=2013;volume=2;issue=1;spage=39;epage=45;aulast=Darvishi;type=0EchocardiographySegmentationSystoleDiastoleEjection FractionCardiac Output
spellingShingle Saeed Darvishi
Hamid Behnam
Majid Pouladian
Niloufar Samiei
Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
Research in Cardiovascular Medicine
Echocardiography
Segmentation
Systole
Diastole
Ejection Fraction
Cardiac Output
title Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
title_full Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
title_fullStr Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
title_full_unstemmed Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
title_short Measuring left ventricular volumes in two-dimensional echocardiography image sequence using level-set method for automatic detection of end-diastole and end-systole frames
title_sort measuring left ventricular volumes in two dimensional echocardiography image sequence using level set method for automatic detection of end diastole and end systole frames
topic Echocardiography
Segmentation
Systole
Diastole
Ejection Fraction
Cardiac Output
url http://www.rcvmonline.com/article.asp?issn=2251-9572;year=2013;volume=2;issue=1;spage=39;epage=45;aulast=Darvishi;type=0
work_keys_str_mv AT saeeddarvishi measuringleftventricularvolumesintwodimensionalechocardiographyimagesequenceusinglevelsetmethodforautomaticdetectionofenddiastoleandendsystoleframes
AT hamidbehnam measuringleftventricularvolumesintwodimensionalechocardiographyimagesequenceusinglevelsetmethodforautomaticdetectionofenddiastoleandendsystoleframes
AT majidpouladian measuringleftventricularvolumesintwodimensionalechocardiographyimagesequenceusinglevelsetmethodforautomaticdetectionofenddiastoleandendsystoleframes
AT niloufarsamiei measuringleftventricularvolumesintwodimensionalechocardiographyimagesequenceusinglevelsetmethodforautomaticdetectionofenddiastoleandendsystoleframes