Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study

Summary: Aim: This study aimed to verify the efficacy of disinfection procedures to reduce Acinetobacter baumannii blaOXA-23 bacterial load in needleless connectors that had been experimentally contaminated. Methods: Two-way intermediate extender's hub and needle-free valve were contaminated w...

Full description

Bibliographic Details
Main Authors: C. Biazus-Dalcin, T.C.M. Sincero, C.P. Zamparette, D.C. Tartari, S. de Souza, T.L. Silva, A. Tomazoni, P.K. Rocha
Format: Article
Language:English
Published: Elsevier 2024-03-01
Series:Infection Prevention in Practice
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2590088923000616
_version_ 1797300386807152640
author C. Biazus-Dalcin
T.C.M. Sincero
C.P. Zamparette
D.C. Tartari
S. de Souza
T.L. Silva
A. Tomazoni
P.K. Rocha
author_facet C. Biazus-Dalcin
T.C.M. Sincero
C.P. Zamparette
D.C. Tartari
S. de Souza
T.L. Silva
A. Tomazoni
P.K. Rocha
author_sort C. Biazus-Dalcin
collection DOAJ
description Summary: Aim: This study aimed to verify the efficacy of disinfection procedures to reduce Acinetobacter baumannii blaOXA-23 bacterial load in needleless connectors that had been experimentally contaminated. Methods: Two-way intermediate extender's hub and needle-free valve were contaminated with Acinetobacter baumannii blaOXA-23. To disinfect them, the following procedures were carried out: sterile gauze with 70% ethanol, sterile gauze with Incidin®, and 70% isopropyl alcohol single-use cap, with eight times friction for 10 s, followed by 5 s drying time. The statistical tests Kruskal–Wallis and post-hoc Conover were performed using MedCalc®. Results: A total of 82 experiments were conducted. All tested disinfection procedures were efficacious in reducing the A. baumannii blaOXA-23 load. The 70% IPA single-use cap was found to be the best method for disinfecting the two-way intermediate extender's hub (87.28%), while all the methods were efficacious for the disinfection of the needle-free valve (more than 90%). During the inoculation period, A. baumannii blaOXA-23 showed less adherence to the needle-free valve during the inoculation period, probably due to the device's design. Conclusion: The three tested disinfection procedures using sterile gauze with 70% ethanol, sterile gauze with Incidin®, and 70% IPA single-use cap were found to be efficacious in reducing the bacterial load of A. baumanni blaOXA-23 in needleless connectors. Proper disinfection of needleless connectors is a crucial nursing practice to prevent bloodstream infections, as it significantly reduces the bacterial load present in the device.
first_indexed 2024-03-07T23:05:27Z
format Article
id doaj.art-c44c9aefbe224c389d0c620a7636747d
institution Directory Open Access Journal
issn 2590-0889
language English
last_indexed 2024-03-07T23:05:27Z
publishDate 2024-03-01
publisher Elsevier
record_format Article
series Infection Prevention in Practice
spelling doaj.art-c44c9aefbe224c389d0c620a7636747d2024-02-22T04:53:17ZengElsevierInfection Prevention in Practice2590-08892024-03-0161100328Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro studyC. Biazus-Dalcin0T.C.M. Sincero1C.P. Zamparette2D.C. Tartari3S. de Souza4T.L. Silva5A. Tomazoni6P.K. Rocha7School of Health Sciences, University of Dundee, Dundee, UK; Corresponding author. Address: School of Health Sciences, University of Dundee, 11 Airlie Place, Dundee, DD1 4HJ, UK. Tel.: +44 1382 385842.Department of Clinical Analyses, Health Sciences Centre, Universidade Federal de Santa Catarina (UFSC), Florianópolis, BrazilDepartment of Clinical Analyses, Health Sciences Centre, Universidade Federal de Santa Catarina (UFSC), Florianópolis, BrazilThe State of Santa Catarina, Florianópolis, BrazilNursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina (UFSC), Florianópolis, BrazilNursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina (UFSC), Florianópolis, BrazilHospital de Clínicas of the Universidade Federal do Paraná (UFPR), Curitiba, BrazilNursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina (UFSC), Florianópolis, BrazilSummary: Aim: This study aimed to verify the efficacy of disinfection procedures to reduce Acinetobacter baumannii blaOXA-23 bacterial load in needleless connectors that had been experimentally contaminated. Methods: Two-way intermediate extender's hub and needle-free valve were contaminated with Acinetobacter baumannii blaOXA-23. To disinfect them, the following procedures were carried out: sterile gauze with 70% ethanol, sterile gauze with Incidin®, and 70% isopropyl alcohol single-use cap, with eight times friction for 10 s, followed by 5 s drying time. The statistical tests Kruskal–Wallis and post-hoc Conover were performed using MedCalc®. Results: A total of 82 experiments were conducted. All tested disinfection procedures were efficacious in reducing the A. baumannii blaOXA-23 load. The 70% IPA single-use cap was found to be the best method for disinfecting the two-way intermediate extender's hub (87.28%), while all the methods were efficacious for the disinfection of the needle-free valve (more than 90%). During the inoculation period, A. baumannii blaOXA-23 showed less adherence to the needle-free valve during the inoculation period, probably due to the device's design. Conclusion: The three tested disinfection procedures using sterile gauze with 70% ethanol, sterile gauze with Incidin®, and 70% IPA single-use cap were found to be efficacious in reducing the bacterial load of A. baumanni blaOXA-23 in needleless connectors. Proper disinfection of needleless connectors is a crucial nursing practice to prevent bloodstream infections, as it significantly reduces the bacterial load present in the device.http://www.sciencedirect.com/science/article/pii/S2590088923000616AcinetobacterBacterial loadCathetersCatheter-related infectionsDisinfection
spellingShingle C. Biazus-Dalcin
T.C.M. Sincero
C.P. Zamparette
D.C. Tartari
S. de Souza
T.L. Silva
A. Tomazoni
P.K. Rocha
Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
Infection Prevention in Practice
Acinetobacter
Bacterial load
Catheters
Catheter-related infections
Disinfection
title Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
title_full Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
title_fullStr Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
title_full_unstemmed Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
title_short Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study
title_sort efficacy of disinfection procedures to reduce acinetobacter baumanii blaoxa 23 contamination rate of needleless connectors an in vitro study
topic Acinetobacter
Bacterial load
Catheters
Catheter-related infections
Disinfection
url http://www.sciencedirect.com/science/article/pii/S2590088923000616
work_keys_str_mv AT cbiazusdalcin efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT tcmsincero efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT cpzamparette efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT dctartari efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT sdesouza efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT tlsilva efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT atomazoni efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy
AT pkrocha efficacyofdisinfectionprocedurestoreduceacinetobacterbaumaniiblaoxa23contaminationrateofneedlelessconnectorsaninvitrostudy