Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters

The trace metal iron (Fe) is an essential micronutrient for phytoplankton growth and limits, or co-limits primary production across much of the world's surface ocean. Iron is a redox sensitive element, with Fe(II) and Fe(III) co-existing in natural waters. Whilst Fe(II) is the most soluble form...

Full description

Bibliographic Details
Main Authors: Felix Geißler, Eric P. Achterberg, Alexander D. Beaton, Mark J. Hopwood, Jennifer S. Clarke, André Mutzberg, Matt C. Mowlem, Douglas P. Connelly
Format: Article
Language:English
Published: Frontiers Media S.A. 2017-10-01
Series:Frontiers in Marine Science
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fmars.2017.00322/full
_version_ 1818561052828237824
author Felix Geißler
Eric P. Achterberg
Eric P. Achterberg
Alexander D. Beaton
Mark J. Hopwood
Jennifer S. Clarke
André Mutzberg
Matt C. Mowlem
Douglas P. Connelly
author_facet Felix Geißler
Eric P. Achterberg
Eric P. Achterberg
Alexander D. Beaton
Mark J. Hopwood
Jennifer S. Clarke
André Mutzberg
Matt C. Mowlem
Douglas P. Connelly
author_sort Felix Geißler
collection DOAJ
description The trace metal iron (Fe) is an essential micronutrient for phytoplankton growth and limits, or co-limits primary production across much of the world's surface ocean. Iron is a redox sensitive element, with Fe(II) and Fe(III) co-existing in natural waters. Whilst Fe(II) is the most soluble form, it is also transient with rapid oxidation rates in oxic seawater. Measurements of Fe(II) are therefore preferably undertaken in situ. For this purpose an autonomous wet chemical analyzer based on lab-on-chip technology was developed for the in situ determination of the concentration of dissolved (<0.45 μm) Fe species (Fe(II) and labile Fe) suitable for deployments in a wide range of aquatic environments. The spectrophotometric approach utilizes a buffered ferrozine solution and a ferrozine/ascorbic acid mixture for Fe(II) and labile Fe(III) analyses, respectively. Diffusive mixing, color development and spectrophotometric detection take place in three separate flow cells with different lengths such that the analyzer can measure a broad concentration range from low nM to several μM of Fe, depending on the desired application. A detection limit of 1.9 nM Fe was found. The microfluidic analyzer was tested in situ for nine days in shallow waters in the Kiel Fjord (Germany) along with other sensors as a part of the SenseOCEAN EU-project. The analyzer's performance under natural conditions was assessed with discrete samples collected and processed according to GEOTRACES protocol [acidified to pH < 2 and analyzed via inductively coupled plasma mass spectrometry (ICP-MS)]. The mechanical performance of the analyzer over the nine day period was good (consistent high precision of Fe(II) and Fe(III) standards with a standard deviation of 2.7% (n = 214) and 1.9% (n = 217), respectively, and successful completion of every programmed data point). However, total dissolved Fe was consistently low compared to ICP-MS data. Recoveries between 16 and 75% were observed, indicating that the analyzer does not measure a significant fraction of natural dissolved Fe species in coastal seawater. It is suggested that an acidification step would be necessary in order to ensure that the analyzer derived total dissolved Fe concentration is reproducible and consistent with discrete values.
first_indexed 2024-12-14T00:46:05Z
format Article
id doaj.art-c46229480cf34dcab9f55d1016c5bbd7
institution Directory Open Access Journal
issn 2296-7745
language English
last_indexed 2024-12-14T00:46:05Z
publishDate 2017-10-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Marine Science
spelling doaj.art-c46229480cf34dcab9f55d1016c5bbd72022-12-21T23:24:07ZengFrontiers Media S.A.Frontiers in Marine Science2296-77452017-10-01410.3389/fmars.2017.00322283384Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal WatersFelix Geißler0Eric P. Achterberg1Eric P. Achterberg2Alexander D. Beaton3Mark J. Hopwood4Jennifer S. Clarke5André Mutzberg6Matt C. Mowlem7Douglas P. Connelly8Chemical Oceanography, Marine Biogeochemistry, GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, GermanyChemical Oceanography, Marine Biogeochemistry, GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, GermanyNational Oceanography Centre, University of Southampton, Southampton, United KingdomNational Oceanography Centre, Southampton, United KingdomChemical Oceanography, Marine Biogeochemistry, GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, GermanyChemical Oceanography, Marine Biogeochemistry, GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, GermanyChemical Oceanography, Marine Biogeochemistry, GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, GermanyNational Oceanography Centre, Southampton, United KingdomNational Oceanography Centre, Southampton, United KingdomThe trace metal iron (Fe) is an essential micronutrient for phytoplankton growth and limits, or co-limits primary production across much of the world's surface ocean. Iron is a redox sensitive element, with Fe(II) and Fe(III) co-existing in natural waters. Whilst Fe(II) is the most soluble form, it is also transient with rapid oxidation rates in oxic seawater. Measurements of Fe(II) are therefore preferably undertaken in situ. For this purpose an autonomous wet chemical analyzer based on lab-on-chip technology was developed for the in situ determination of the concentration of dissolved (<0.45 μm) Fe species (Fe(II) and labile Fe) suitable for deployments in a wide range of aquatic environments. The spectrophotometric approach utilizes a buffered ferrozine solution and a ferrozine/ascorbic acid mixture for Fe(II) and labile Fe(III) analyses, respectively. Diffusive mixing, color development and spectrophotometric detection take place in three separate flow cells with different lengths such that the analyzer can measure a broad concentration range from low nM to several μM of Fe, depending on the desired application. A detection limit of 1.9 nM Fe was found. The microfluidic analyzer was tested in situ for nine days in shallow waters in the Kiel Fjord (Germany) along with other sensors as a part of the SenseOCEAN EU-project. The analyzer's performance under natural conditions was assessed with discrete samples collected and processed according to GEOTRACES protocol [acidified to pH < 2 and analyzed via inductively coupled plasma mass spectrometry (ICP-MS)]. The mechanical performance of the analyzer over the nine day period was good (consistent high precision of Fe(II) and Fe(III) standards with a standard deviation of 2.7% (n = 214) and 1.9% (n = 217), respectively, and successful completion of every programmed data point). However, total dissolved Fe was consistently low compared to ICP-MS data. Recoveries between 16 and 75% were observed, indicating that the analyzer does not measure a significant fraction of natural dissolved Fe species in coastal seawater. It is suggested that an acidification step would be necessary in order to ensure that the analyzer derived total dissolved Fe concentration is reproducible and consistent with discrete values.http://journal.frontiersin.org/article/10.3389/fmars.2017.00322/fullcoastal watersdissolved ironferrozinespectrophotometryin situ chemical analyzerlab-on-chip
spellingShingle Felix Geißler
Eric P. Achterberg
Eric P. Achterberg
Alexander D. Beaton
Mark J. Hopwood
Jennifer S. Clarke
André Mutzberg
Matt C. Mowlem
Douglas P. Connelly
Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
Frontiers in Marine Science
coastal waters
dissolved iron
ferrozine
spectrophotometry
in situ chemical analyzer
lab-on-chip
title Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
title_full Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
title_fullStr Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
title_full_unstemmed Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
title_short Evaluation of a Ferrozine Based Autonomous in Situ Lab-on-Chip Analyzer for Dissolved Iron Species in Coastal Waters
title_sort evaluation of a ferrozine based autonomous in situ lab on chip analyzer for dissolved iron species in coastal waters
topic coastal waters
dissolved iron
ferrozine
spectrophotometry
in situ chemical analyzer
lab-on-chip
url http://journal.frontiersin.org/article/10.3389/fmars.2017.00322/full
work_keys_str_mv AT felixgeißler evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT ericpachterberg evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT ericpachterberg evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT alexanderdbeaton evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT markjhopwood evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT jennifersclarke evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT andremutzberg evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT mattcmowlem evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters
AT douglaspconnelly evaluationofaferrozinebasedautonomousinsitulabonchipanalyzerfordissolvedironspeciesincoastalwaters