Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach

Study Design A preliminary case series study. Purpose For the safety of performing a posterior percutaneous full-endoscopic cervical discectomy. Overview of Literature Because of the lack of space for inserting an outer sheath above the intervertebral disc in the spinal canal, grasping the herniated...

Full description

Bibliographic Details
Main Authors: Shu Nakamura, Mitsuto Taguchi
Format: Article
Language:English
Published: Korean Spine Society 2020-08-01
Series:Asian Spine Journal
Subjects:
Online Access:http://www.asianspinejournal.org/upload/pdf/asj-2019-0137.pdf
_version_ 1819277930213146624
author Shu Nakamura
Mitsuto Taguchi
author_facet Shu Nakamura
Mitsuto Taguchi
author_sort Shu Nakamura
collection DOAJ
description Study Design A preliminary case series study. Purpose For the safety of performing a posterior percutaneous full-endoscopic cervical discectomy. Overview of Literature Because of the lack of space for inserting an outer sheath above the intervertebral disc in the spinal canal, grasping the herniated disc with forceps while retracting the nerves with the forceps itself was required. This procedure produces the risk of inadvertently injuring nerves because of inadequate visualization of the hernia and inadequate protection of the nerve. Methods Our new internal retractor can be inserted into the working channel of a percutaneous full-endoscope, enabling the insertion of a second tool. After partial foraminotomy, the internal retractor and forceps were manipulated to reliably retract the nerve root. Finally, the herniated disc was resected under an endoscopic view. Results All six cases had a good postoperative course, and postoperative neuropathy was not observed. Conclusions This internal retractor allows for the secure resection herniated cervical intervertebral discs.
first_indexed 2024-12-24T00:03:56Z
format Article
id doaj.art-c545969c44674cec810599d3ae072963
institution Directory Open Access Journal
issn 1976-1902
1976-7846
language English
last_indexed 2024-12-24T00:03:56Z
publishDate 2020-08-01
publisher Korean Spine Society
record_format Article
series Asian Spine Journal
spelling doaj.art-c545969c44674cec810599d3ae0729632022-12-21T17:25:03ZengKorean Spine SocietyAsian Spine Journal1976-19021976-78462020-08-0114448949410.31616/asj.2019.01371163Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior ApproachShu NakamuraMitsuto Taguchi0Department of Orthopedic Surgery, Aichi Spine Hospital, Inuyama, JapanStudy Design A preliminary case series study. Purpose For the safety of performing a posterior percutaneous full-endoscopic cervical discectomy. Overview of Literature Because of the lack of space for inserting an outer sheath above the intervertebral disc in the spinal canal, grasping the herniated disc with forceps while retracting the nerves with the forceps itself was required. This procedure produces the risk of inadvertently injuring nerves because of inadequate visualization of the hernia and inadequate protection of the nerve. Methods Our new internal retractor can be inserted into the working channel of a percutaneous full-endoscope, enabling the insertion of a second tool. After partial foraminotomy, the internal retractor and forceps were manipulated to reliably retract the nerve root. Finally, the herniated disc was resected under an endoscopic view. Results All six cases had a good postoperative course, and postoperative neuropathy was not observed. Conclusions This internal retractor allows for the secure resection herniated cervical intervertebral discs.http://www.asianspinejournal.org/upload/pdf/asj-2019-0137.pdfspineherniated discdiscectomypercutaneous
spellingShingle Shu Nakamura
Mitsuto Taguchi
Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
Asian Spine Journal
spine
herniated disc
discectomy
percutaneous
title Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
title_full Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
title_fullStr Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
title_full_unstemmed Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
title_short Use of an Internal Retractor for Percutaneous Full-Endoscopic Resection in Cervical Intervertebral Disc Herniation with a Posterior Approach
title_sort use of an internal retractor for percutaneous full endoscopic resection in cervical intervertebral disc herniation with a posterior approach
topic spine
herniated disc
discectomy
percutaneous
url http://www.asianspinejournal.org/upload/pdf/asj-2019-0137.pdf
work_keys_str_mv AT shunakamura useofaninternalretractorforpercutaneousfullendoscopicresectionincervicalintervertebraldischerniationwithaposteriorapproach
AT mitsutotaguchi useofaninternalretractorforpercutaneousfullendoscopicresectionincervicalintervertebraldischerniationwithaposteriorapproach