Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System

Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple a...

Full description

Bibliographic Details
Main Authors: Rofiatul Izah, Subiyanto Subiyanto, Dhidik Prastiyanto
Format: Article
Language:English
Published: Indonesian Institute of Sciences 2018-08-01
Series:Jurnal Elektronika dan Telekomunikasi
Subjects:
Online Access:http://www.jurnalet.com/jet/article/view/220
_version_ 1818504742711590912
author Rofiatul Izah
Subiyanto Subiyanto
Dhidik Prastiyanto
author_facet Rofiatul Izah
Subiyanto Subiyanto
Dhidik Prastiyanto
author_sort Rofiatul Izah
collection DOAJ
description Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.
first_indexed 2024-12-10T21:41:18Z
format Article
id doaj.art-c56f2288cbd542adbca090d61470ad76
institution Directory Open Access Journal
issn 1411-8289
2527-9955
language English
last_indexed 2024-12-10T21:41:18Z
publishDate 2018-08-01
publisher Indonesian Institute of Sciences
record_format Article
series Jurnal Elektronika dan Telekomunikasi
spelling doaj.art-c56f2288cbd542adbca090d61470ad762022-12-22T01:32:30ZengIndonesian Institute of SciencesJurnal Elektronika dan Telekomunikasi1411-82892527-99552018-08-01181354510.14203/jet.v18.35-45138Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic SystemRofiatul Izah0Subiyanto Subiyanto1Dhidik Prastiyanto2UNIVERSITAS NEGERI SEMARANGUNIVERSITAS NEGERI SEMARANGUNIVERSITAS NEGERI SEMARANGSynchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.http://www.jurnalet.com/jet/article/view/220synchronizationDSOGI PLLPSIMphotovoltaic systemgrid connected
spellingShingle Rofiatul Izah
Subiyanto Subiyanto
Dhidik Prastiyanto
Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
Jurnal Elektronika dan Telekomunikasi
synchronization
DSOGI PLL
PSIM
photovoltaic system
grid connected
title Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
title_full Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
title_fullStr Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
title_full_unstemmed Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
title_short Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System
title_sort improvement of dsogi pll synchronization algorithm with filter on three phase grid connected photovoltaic system
topic synchronization
DSOGI PLL
PSIM
photovoltaic system
grid connected
url http://www.jurnalet.com/jet/article/view/220
work_keys_str_mv AT rofiatulizah improvementofdsogipllsynchronizationalgorithmwithfilteronthreephasegridconnectedphotovoltaicsystem
AT subiyantosubiyanto improvementofdsogipllsynchronizationalgorithmwithfilteronthreephasegridconnectedphotovoltaicsystem
AT dhidikprastiyanto improvementofdsogipllsynchronizationalgorithmwithfilteronthreephasegridconnectedphotovoltaicsystem