Evaluation of Cell Counter Machines in Medical Laboratories

Background and aim:Blood cells have an important role in human healthy, so their shapes and numbers are defined as human healthy indexes. These factors are measured by cell counter machines. Presenting a high quality report according to cell counters output is dependant on their operational accuracy...

Full description

Bibliographic Details
Main Authors: Ghazi MirSaeid SDJ, Mireshgholah M, Changizi V
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2007-05-01
Series:پیاورد سلامت
Subjects:
Online Access:http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4293.pdf&manuscript_id=4293
_version_ 1818732459022352384
author Ghazi MirSaeid SDJ
Mireshgholah M
Changizi V
author_facet Ghazi MirSaeid SDJ
Mireshgholah M
Changizi V
author_sort Ghazi MirSaeid SDJ
collection DOAJ
description Background and aim:Blood cells have an important role in human healthy, so their shapes and numbers are defined as human healthy indexes. These factors are measured by cell counter machines. Presenting a high quality report according to cell counters output is dependant on their operational accuracy. Therefore it was necessary to do a study on quality control of blood cell counter machines in selective medical laboratories of Tehran.Method of study:This study was an experimental type in selective medical laboratories of Tehran. "Brittin method" was used as a general method for 6 selective machines over WBC, RBC, Hb, HCT, MCV, MCH and MCHC. In this method red blood cells index stability with EDTA, in 4oC for 24 hour is assessed. Data was collected before and after quality controls and finally data analysis was done by T- student (paired samples T test) method and SPSS software.Results:Using Brittin method showed all selective machines had significant differences before and after quality control in one or more quality factors (P-value< 0.05).Conclusion:Quality control can show inaccuracy in cell counter machines output and finally inaccuracy over patient blood tests. By this subject we can have high quality diagnosis. This study showed parameters producing errors are error in sample volume, biological factors, error in concentration and using bad solutions.
first_indexed 2024-12-17T23:33:54Z
format Article
id doaj.art-c579fca4d093498a8513b5eb7f17c0ba
institution Directory Open Access Journal
issn 1735-8132
2008-2665
language fas
last_indexed 2024-12-17T23:33:54Z
publishDate 2007-05-01
publisher Tehran University of Medical Sciences
record_format Article
series پیاورد سلامت
spelling doaj.art-c579fca4d093498a8513b5eb7f17c0ba2022-12-21T21:28:36ZfasTehran University of Medical Sciencesپیاورد سلامت1735-81322008-26652007-05-01113944Evaluation of Cell Counter Machines in Medical LaboratoriesGhazi MirSaeid SDJMireshgholah MChangizi VBackground and aim:Blood cells have an important role in human healthy, so their shapes and numbers are defined as human healthy indexes. These factors are measured by cell counter machines. Presenting a high quality report according to cell counters output is dependant on their operational accuracy. Therefore it was necessary to do a study on quality control of blood cell counter machines in selective medical laboratories of Tehran.Method of study:This study was an experimental type in selective medical laboratories of Tehran. "Brittin method" was used as a general method for 6 selective machines over WBC, RBC, Hb, HCT, MCV, MCH and MCHC. In this method red blood cells index stability with EDTA, in 4oC for 24 hour is assessed. Data was collected before and after quality controls and finally data analysis was done by T- student (paired samples T test) method and SPSS software.Results:Using Brittin method showed all selective machines had significant differences before and after quality control in one or more quality factors (P-value< 0.05).Conclusion:Quality control can show inaccuracy in cell counter machines output and finally inaccuracy over patient blood tests. By this subject we can have high quality diagnosis. This study showed parameters producing errors are error in sample volume, biological factors, error in concentration and using bad solutions.http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4293.pdf&manuscript_id=4293Brittin Test
spellingShingle Ghazi MirSaeid SDJ
Mireshgholah M
Changizi V
Evaluation of Cell Counter Machines in Medical Laboratories
پیاورد سلامت
Brittin Test
title Evaluation of Cell Counter Machines in Medical Laboratories
title_full Evaluation of Cell Counter Machines in Medical Laboratories
title_fullStr Evaluation of Cell Counter Machines in Medical Laboratories
title_full_unstemmed Evaluation of Cell Counter Machines in Medical Laboratories
title_short Evaluation of Cell Counter Machines in Medical Laboratories
title_sort evaluation of cell counter machines in medical laboratories
topic Brittin Test
url http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4293.pdf&manuscript_id=4293
work_keys_str_mv AT ghazimirsaeidsdj evaluationofcellcountermachinesinmedicallaboratories
AT mireshgholahm evaluationofcellcountermachinesinmedicallaboratories
AT changiziv evaluationofcellcountermachinesinmedicallaboratories