Power supply risk assessment method for relay protection system faults

The influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to. A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and...

Full description

Bibliographic Details
Main Authors: Tuyou Si, Jiekang Wu, Weideng Yuan, Anan Du
Format: Article
Language:English
Published: Polish Academy of Sciences 2016-12-01
Series:Archives of Electrical Engineering
Subjects:
Online Access:http://www.degruyter.com/view/j/aee.2016.65.issue-4/aee-2016-0056/aee-2016-0056.xml?format=INT
_version_ 1818536323268476928
author Tuyou Si
Jiekang Wu
Weideng Yuan
Anan Du
author_facet Tuyou Si
Jiekang Wu
Weideng Yuan
Anan Du
author_sort Tuyou Si
collection DOAJ
description The influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to. A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and non-operation of the relay protection systems, and failure probability model of relay protection system is constructed and simplified. The effects of dominant faults, hidden misoperation and non-operation of the relay protection systems on the reduced power supply load power are analysed, and a probabilistic model for reduced power supply load power is constructed by three parts corresponding to dominant faults, hidden misoperation and non-operation. A probability calculation method of power supply risk occurrence due to hidden faults of relay protecttion system is proposed considering the fault probability of the relay protection systems, the frequency of the hidden faults occurring in operation period, the reduced power supply load power or load power outage, and the connection mode of the in-lines, out-lines and transformers in a substation. The feasibility and applicability of the proposed method for estimation of risk value probability of the relay protection systems is verified by two studied examples.
first_indexed 2024-12-11T18:36:28Z
format Article
id doaj.art-c57fe5ecf05e468dbb8c2eac4f93dc66
institution Directory Open Access Journal
issn 2300-2506
language English
last_indexed 2024-12-11T18:36:28Z
publishDate 2016-12-01
publisher Polish Academy of Sciences
record_format Article
series Archives of Electrical Engineering
spelling doaj.art-c57fe5ecf05e468dbb8c2eac4f93dc662022-12-22T00:54:44ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062016-12-0165480381410.1515/aee-2016-0056aee-2016-0056Power supply risk assessment method for relay protection system faultsTuyou Si0Jiekang Wu1Weideng Yuan2Anan Du3Dongguan Power Supply Bureau Guangdong Power Grid Co., Ltd Dongguan 523008, ChinaSchool of Automation Guangdong University of Technology Guangzhou, 510006, ChinaDongguan Power Supply Bureau Guangdong Power Grid Co., Ltd Dongguan 523008, ChinaSchool of Automation Guangdong University of Technology Guangzhou, 510006, ChinaThe influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to. A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and non-operation of the relay protection systems, and failure probability model of relay protection system is constructed and simplified. The effects of dominant faults, hidden misoperation and non-operation of the relay protection systems on the reduced power supply load power are analysed, and a probabilistic model for reduced power supply load power is constructed by three parts corresponding to dominant faults, hidden misoperation and non-operation. A probability calculation method of power supply risk occurrence due to hidden faults of relay protecttion system is proposed considering the fault probability of the relay protection systems, the frequency of the hidden faults occurring in operation period, the reduced power supply load power or load power outage, and the connection mode of the in-lines, out-lines and transformers in a substation. The feasibility and applicability of the proposed method for estimation of risk value probability of the relay protection systems is verified by two studied examples.http://www.degruyter.com/view/j/aee.2016.65.issue-4/aee-2016-0056/aee-2016-0056.xml?format=INTreduced power supply load powerrelay protection systemsrisk valuepower supply risk assessment
spellingShingle Tuyou Si
Jiekang Wu
Weideng Yuan
Anan Du
Power supply risk assessment method for relay protection system faults
Archives of Electrical Engineering
reduced power supply load power
relay protection systems
risk value
power supply risk assessment
title Power supply risk assessment method for relay protection system faults
title_full Power supply risk assessment method for relay protection system faults
title_fullStr Power supply risk assessment method for relay protection system faults
title_full_unstemmed Power supply risk assessment method for relay protection system faults
title_short Power supply risk assessment method for relay protection system faults
title_sort power supply risk assessment method for relay protection system faults
topic reduced power supply load power
relay protection systems
risk value
power supply risk assessment
url http://www.degruyter.com/view/j/aee.2016.65.issue-4/aee-2016-0056/aee-2016-0056.xml?format=INT
work_keys_str_mv AT tuyousi powersupplyriskassessmentmethodforrelayprotectionsystemfaults
AT jiekangwu powersupplyriskassessmentmethodforrelayprotectionsystemfaults
AT weidengyuan powersupplyriskassessmentmethodforrelayprotectionsystemfaults
AT anandu powersupplyriskassessmentmethodforrelayprotectionsystemfaults