Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography

In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as Hi...

Full description

Bibliographic Details
Main Authors: Sandun Jayarathna, Hem Moktan, Sang Hyun Cho
Format: Article
Language:English
Published: IEEE 2022-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9905602/
_version_ 1817983762925879296
author Sandun Jayarathna
Hem Moktan
Sang Hyun Cho
author_facet Sandun Jayarathna
Hem Moktan
Sang Hyun Cho
author_sort Sandun Jayarathna
collection DOAJ
description In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm3 or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/ x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.
first_indexed 2024-04-13T23:37:27Z
format Article
id doaj.art-c5e3a948a8d146e590fde6f29e43bd65
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-04-13T23:37:27Z
publishDate 2022-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-c5e3a948a8d146e590fde6f29e43bd652022-12-22T02:24:41ZengIEEEIEEE Access2169-35362022-01-011010507410508310.1109/ACCESS.2022.32105909905602Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed TomographySandun Jayarathna0Hem Moktan1Sang Hyun Cho2https://orcid.org/0000-0002-6357-5042Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USADepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USADepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USAIn this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm3 or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/ x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.https://ieeexplore.ieee.org/document/9905602/X-ray fluorescenceX-ray fluorescence computed tomographyCdTe detectorHEXITECgold nanoparticlequantitative imaging
spellingShingle Sandun Jayarathna
Hem Moktan
Sang Hyun Cho
Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
IEEE Access
X-ray fluorescence
X-ray fluorescence computed tomography
CdTe detector
HEXITEC
gold nanoparticle
quantitative imaging
title Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_full Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_fullStr Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_full_unstemmed Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_short Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_sort use of the fully spectroscopic pixelated cadmium telluride detector for benchtop x ray fluorescence computed tomography
topic X-ray fluorescence
X-ray fluorescence computed tomography
CdTe detector
HEXITEC
gold nanoparticle
quantitative imaging
url https://ieeexplore.ieee.org/document/9905602/
work_keys_str_mv AT sandunjayarathna useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography
AT hemmoktan useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography
AT sanghyuncho useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography