Static modulus of elasticity of concrete measured by the ultrasonic method

Lately, a huge number of accidents caused by problems found in the durability of concrete structures due to inappropriate project design, lack of control of quality during the project \s execution, inadequate maintenance practices and an aggressive environment has been reported. This finding has req...

Full description

Bibliographic Details
Main Authors: G. S. Sena Rodrigues, E. Pazini Figueiredo
Format: Article
Language:English
Published: Consejo Superior de Investigaciones Científicas 2003-12-01
Series:Materiales de Construccion
Subjects:
Online Access:http://materconstrucc.revistas.csic.es/index.php/materconstrucc/article/view/288
_version_ 1818458328649433088
author G. S. Sena Rodrigues
E. Pazini Figueiredo
author_facet G. S. Sena Rodrigues
E. Pazini Figueiredo
author_sort G. S. Sena Rodrigues
collection DOAJ
description Lately, a huge number of accidents caused by problems found in the durability of concrete structures due to inappropriate project design, lack of control of quality during the project \s execution, inadequate maintenance practices and an aggressive environment has been reported. This finding has required from the professionals constant inspections and evaluations of the real conditions of all concrete structures. In order to perform those inspections, one should know not only the elastic modulus to analyze the concrete structural behaviour but also to investigate its performance, since the strains may yield cracks able to compromise the durability- of structures. Non-destructive testing techniques, particularly the ultrasonic testing, are performed to evaluate and determine the quality of a concrete structure or element. Currently, such essays have been widely researched and analyzed all over the world because they enable the examination of structures without damaging them. The purpose of the present study was to correlate the ultrasonic pulse velocity and the elastic modulus of several concrete specimens molded with a range of water-cement ratios, different kinds of aggregates and curing methods. All the concrete specimens were tested in different ages to determine the pulse velocity and the static modulus of elasticity standardized according to KBR 8522, through mechanical extensometers, electrical strain gauge and LVTD inductive transducer.
first_indexed 2024-12-14T22:56:43Z
format Article
id doaj.art-c5f6f0569b654e6caa74c83611de56f8
institution Directory Open Access Journal
issn 0465-2746
1988-3226
language English
last_indexed 2024-12-14T22:56:43Z
publishDate 2003-12-01
publisher Consejo Superior de Investigaciones Científicas
record_format Article
series Materiales de Construccion
spelling doaj.art-c5f6f0569b654e6caa74c83611de56f82022-12-21T22:44:34ZengConsejo Superior de Investigaciones CientíficasMateriales de Construccion0465-27461988-32262003-12-0153271-272475810.3989/mc.2003.v53.i271-272.288275Static modulus of elasticity of concrete measured by the ultrasonic methodG. S. Sena Rodrigues0E. Pazini Figueiredo1Escuela de Ingeniería Civil de la Universidad Federal de GoiásEscuela de Ingeniería Civil de la Universidad Federal de GoiásLately, a huge number of accidents caused by problems found in the durability of concrete structures due to inappropriate project design, lack of control of quality during the project \s execution, inadequate maintenance practices and an aggressive environment has been reported. This finding has required from the professionals constant inspections and evaluations of the real conditions of all concrete structures. In order to perform those inspections, one should know not only the elastic modulus to analyze the concrete structural behaviour but also to investigate its performance, since the strains may yield cracks able to compromise the durability- of structures. Non-destructive testing techniques, particularly the ultrasonic testing, are performed to evaluate and determine the quality of a concrete structure or element. Currently, such essays have been widely researched and analyzed all over the world because they enable the examination of structures without damaging them. The purpose of the present study was to correlate the ultrasonic pulse velocity and the elastic modulus of several concrete specimens molded with a range of water-cement ratios, different kinds of aggregates and curing methods. All the concrete specimens were tested in different ages to determine the pulse velocity and the static modulus of elasticity standardized according to KBR 8522, through mechanical extensometers, electrical strain gauge and LVTD inductive transducer.http://materconstrucc.revistas.csic.es/index.php/materconstrucc/article/view/288concreteultrasoundultrasonic pulse velocityelastic modulusstatic modulus of elasticitydynamic modulus of elasticity
spellingShingle G. S. Sena Rodrigues
E. Pazini Figueiredo
Static modulus of elasticity of concrete measured by the ultrasonic method
Materiales de Construccion
concrete
ultrasound
ultrasonic pulse velocity
elastic modulus
static modulus of elasticity
dynamic modulus of elasticity
title Static modulus of elasticity of concrete measured by the ultrasonic method
title_full Static modulus of elasticity of concrete measured by the ultrasonic method
title_fullStr Static modulus of elasticity of concrete measured by the ultrasonic method
title_full_unstemmed Static modulus of elasticity of concrete measured by the ultrasonic method
title_short Static modulus of elasticity of concrete measured by the ultrasonic method
title_sort static modulus of elasticity of concrete measured by the ultrasonic method
topic concrete
ultrasound
ultrasonic pulse velocity
elastic modulus
static modulus of elasticity
dynamic modulus of elasticity
url http://materconstrucc.revistas.csic.es/index.php/materconstrucc/article/view/288
work_keys_str_mv AT gssenarodrigues staticmodulusofelasticityofconcretemeasuredbytheultrasonicmethod
AT epazinifigueiredo staticmodulusofelasticityofconcretemeasuredbytheultrasonicmethod