A modified method of evisceration of a subatrophic eyeball
The purpose is to develop a new method of evisceration of the eyeball in II–III degree subatrophies and assess its effectiveness. Material and methods. 172 patients with blind or incurable eyes who underwent one of the three operations: eye evisceration according to the newly developed technique inv...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Real Time Ltd
2020-05-01
|
Series: | Российский офтальмологический журнал |
Subjects: | |
Online Access: | https://roj.igb.ru/jour/article/view/433 |
_version_ | 1797878319144763392 |
---|---|
author | I. A. Filatova E. M. Mohammad S. A. Shemetov |
author_facet | I. A. Filatova E. M. Mohammad S. A. Shemetov |
author_sort | I. A. Filatova |
collection | DOAJ |
description | The purpose is to develop a new method of evisceration of the eyeball in II–III degree subatrophies and assess its effectiveness. Material and methods. 172 patients with blind or incurable eyes who underwent one of the three operations: eye evisceration according to the newly developed technique involving an implantation of polytetrafluoroethylene grafts (main group), eyeball enucleation (comparison group I) and classical eye evisceration (comparison group II) were observed. Results. No complications were revealed either in the early or in the late period. A positive result was noted in all patients of the main group: average stump mobility was 140.1° ± 3.7° and average prosthesis mobility was 111.2° ± 4.0°. Prosthesis retraction after evisceration occurred 13.9 % less often than after enucleation (comparison group I), while the prosthesis retraction depth (mm) was 54.5 % lower than after enucleation. The retraction of the upper eyelid was also 26 % less common and its depth (mm) was 39.3 % lower. |
first_indexed | 2024-04-10T02:31:51Z |
format | Article |
id | doaj.art-c61f3b18ae314021a29e81c810b550da |
institution | Directory Open Access Journal |
issn | 2072-0076 2587-5760 |
language | Russian |
last_indexed | 2024-04-10T02:31:51Z |
publishDate | 2020-05-01 |
publisher | Real Time Ltd |
record_format | Article |
series | Российский офтальмологический журнал |
spelling | doaj.art-c61f3b18ae314021a29e81c810b550da2023-03-13T07:54:30ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602020-05-01132596410.21516/2072-0076-2020-13-2-59-64286A modified method of evisceration of a subatrophic eyeballI. A. Filatova0E. M. Mohammad1S. A. Shemetov2ФГБУ «НМИЦ глазных болезней им. Гельмгольца» Минздрава РоссииФГБУ «НМИЦ глазных болезней им. Гельмгольца» Минздрава РоссииФГБУ «НМИЦ глазных болезней им. Гельмгольца» Минздрава РоссииThe purpose is to develop a new method of evisceration of the eyeball in II–III degree subatrophies and assess its effectiveness. Material and methods. 172 patients with blind or incurable eyes who underwent one of the three operations: eye evisceration according to the newly developed technique involving an implantation of polytetrafluoroethylene grafts (main group), eyeball enucleation (comparison group I) and classical eye evisceration (comparison group II) were observed. Results. No complications were revealed either in the early or in the late period. A positive result was noted in all patients of the main group: average stump mobility was 140.1° ± 3.7° and average prosthesis mobility was 111.2° ± 4.0°. Prosthesis retraction after evisceration occurred 13.9 % less often than after enucleation (comparison group I), while the prosthesis retraction depth (mm) was 54.5 % lower than after enucleation. The retraction of the upper eyelid was also 26 % less common and its depth (mm) was 39.3 % lower.https://roj.igb.ru/jour/article/view/433эвисцерацияэнуклеацияполитетрафторэтиленпластика культиорбитальный имплантат |
spellingShingle | I. A. Filatova E. M. Mohammad S. A. Shemetov A modified method of evisceration of a subatrophic eyeball Российский офтальмологический журнал эвисцерация энуклеация политетрафторэтилен пластика культи орбитальный имплантат |
title | A modified method of evisceration of a subatrophic eyeball |
title_full | A modified method of evisceration of a subatrophic eyeball |
title_fullStr | A modified method of evisceration of a subatrophic eyeball |
title_full_unstemmed | A modified method of evisceration of a subatrophic eyeball |
title_short | A modified method of evisceration of a subatrophic eyeball |
title_sort | modified method of evisceration of a subatrophic eyeball |
topic | эвисцерация энуклеация политетрафторэтилен пластика культи орбитальный имплантат |
url | https://roj.igb.ru/jour/article/view/433 |
work_keys_str_mv | AT iafilatova amodifiedmethodofeviscerationofasubatrophiceyeball AT emmohammad amodifiedmethodofeviscerationofasubatrophiceyeball AT sashemetov amodifiedmethodofeviscerationofasubatrophiceyeball AT iafilatova modifiedmethodofeviscerationofasubatrophiceyeball AT emmohammad modifiedmethodofeviscerationofasubatrophiceyeball AT sashemetov modifiedmethodofeviscerationofasubatrophiceyeball |