Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.

BACKGROUND: The stability of the accuracy of a diagnostic test is critical to whether clinicians can rely on its result. We aimed to assess whether the performance of a rapid antigen detection test (RADT) for group A streptococcus (GAS) is affected by the clinical spectrum and/or bacterial inoculum...

Full description

Bibliographic Details
Main Authors: Jérémie F Cohen, Martin Chalumeau, Corinne Levy, Philippe Bidet, Franck Thollot, Alain Wollner, Edouard Bingen, Robert Cohen
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2012-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3387167?pdf=render
_version_ 1818276667951415296
author Jérémie F Cohen
Martin Chalumeau
Corinne Levy
Philippe Bidet
Franck Thollot
Alain Wollner
Edouard Bingen
Robert Cohen
author_facet Jérémie F Cohen
Martin Chalumeau
Corinne Levy
Philippe Bidet
Franck Thollot
Alain Wollner
Edouard Bingen
Robert Cohen
author_sort Jérémie F Cohen
collection DOAJ
description BACKGROUND: The stability of the accuracy of a diagnostic test is critical to whether clinicians can rely on its result. We aimed to assess whether the performance of a rapid antigen detection test (RADT) for group A streptococcus (GAS) is affected by the clinical spectrum and/or bacterial inoculum size. METHODS: Throat swabs were collected from 785 children with pharyngitis in an office-based, prospective, multicenter study (2009-2010). We analysed the effect of clinical spectrum (i.e., the McIsaac score and its components) and inoculum size (light or heavy GAS growth) on the accuracy (sensitivity, specificity, likelihood ratios and predictive values) of a RADT, with laboratory throat culture as the reference test. We also evaluated the accuracy of a McIsaac-score-based decision rule. RESULTS: GAS prevalence was 36% (95CI: 33%-40%). The inoculum was heavy for 85% of cases (81%-89%). We found a significant spectrum effect on sensitivity, specificity, likelihood ratios and positive predictive value (p<0.05) but not negative predictive value, which was stable at about 92%. RADT sensitivity was greater for children with heavy than light inoculum (95% vs. 40%, p<0.001). After stratification by inoculum size, the spectrum effect on RADT sensitivity was significant only in patients with light inoculum, on univariate and multivariate analysis. The McIsaac-score-based decision rule had 99% (97%-100%) sensitivity and 52% (48%-57%) specificity. CONCLUSIONS: Variations in RADT sensitivity only occur in patients with light inocula. Because the spectrum effect does not affect the negative predictive value of the test, clinicians who want to rule out GAS can rely on negative RADT results regardless of clinical features if they accept that about 10% of children with negative RADT results will have a positive throat culture. However, such a policy is more acceptable in populations with very low incidence of complications of GAS infection.
first_indexed 2024-12-12T22:49:18Z
format Article
id doaj.art-c6859b1b97b54eb488ade048fa128ab0
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-12T22:49:18Z
publishDate 2012-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-c6859b1b97b54eb488ade048fa128ab02022-12-22T00:09:06ZengPublic Library of Science (PLoS)PLoS ONE1932-62032012-01-0176e3908510.1371/journal.pone.0039085Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.Jérémie F CohenMartin ChalumeauCorinne LevyPhilippe BidetFranck ThollotAlain WollnerEdouard BingenRobert CohenBACKGROUND: The stability of the accuracy of a diagnostic test is critical to whether clinicians can rely on its result. We aimed to assess whether the performance of a rapid antigen detection test (RADT) for group A streptococcus (GAS) is affected by the clinical spectrum and/or bacterial inoculum size. METHODS: Throat swabs were collected from 785 children with pharyngitis in an office-based, prospective, multicenter study (2009-2010). We analysed the effect of clinical spectrum (i.e., the McIsaac score and its components) and inoculum size (light or heavy GAS growth) on the accuracy (sensitivity, specificity, likelihood ratios and predictive values) of a RADT, with laboratory throat culture as the reference test. We also evaluated the accuracy of a McIsaac-score-based decision rule. RESULTS: GAS prevalence was 36% (95CI: 33%-40%). The inoculum was heavy for 85% of cases (81%-89%). We found a significant spectrum effect on sensitivity, specificity, likelihood ratios and positive predictive value (p<0.05) but not negative predictive value, which was stable at about 92%. RADT sensitivity was greater for children with heavy than light inoculum (95% vs. 40%, p<0.001). After stratification by inoculum size, the spectrum effect on RADT sensitivity was significant only in patients with light inoculum, on univariate and multivariate analysis. The McIsaac-score-based decision rule had 99% (97%-100%) sensitivity and 52% (48%-57%) specificity. CONCLUSIONS: Variations in RADT sensitivity only occur in patients with light inocula. Because the spectrum effect does not affect the negative predictive value of the test, clinicians who want to rule out GAS can rely on negative RADT results regardless of clinical features if they accept that about 10% of children with negative RADT results will have a positive throat culture. However, such a policy is more acceptable in populations with very low incidence of complications of GAS infection.http://europepmc.org/articles/PMC3387167?pdf=render
spellingShingle Jérémie F Cohen
Martin Chalumeau
Corinne Levy
Philippe Bidet
Franck Thollot
Alain Wollner
Edouard Bingen
Robert Cohen
Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
PLoS ONE
title Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
title_full Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
title_fullStr Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
title_full_unstemmed Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
title_short Spectrum and inoculum size effect of a rapid antigen detection test for group A streptococcus in children with pharyngitis.
title_sort spectrum and inoculum size effect of a rapid antigen detection test for group a streptococcus in children with pharyngitis
url http://europepmc.org/articles/PMC3387167?pdf=render
work_keys_str_mv AT jeremiefcohen spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT martinchalumeau spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT corinnelevy spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT philippebidet spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT franckthollot spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT alainwollner spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT edouardbingen spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis
AT robertcohen spectrumandinoculumsizeeffectofarapidantigendetectiontestforgroupastreptococcusinchildrenwithpharyngitis