RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE
In the course of intensive therapy for central venous catheterization is a high risk of mechanical complications. The probability of damage to the nervus vagus in the catheterization internal jugular vein is very high, but the lack of vigilance of medical personnel and damage to the knowledge of the...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
SINAPS LLC
2017-08-01
|
Series: | Архивъ внутренней медицины |
Subjects: | |
Online Access: | https://www.medarhive.ru/jour/article/view/685 |
_version_ | 1797883803940683776 |
---|---|
author | M. V. Bykov V. V. Lazarev K. S. Madorskii V. G. Bagaev L. V. Bykova |
author_facet | M. V. Bykov V. V. Lazarev K. S. Madorskii V. G. Bagaev L. V. Bykova |
author_sort | M. V. Bykov |
collection | DOAJ |
description | In the course of intensive therapy for central venous catheterization is a high risk of mechanical complications. The probability of damage to the nervus vagus in the catheterization internal jugular vein is very high, but the lack of vigilance of medical personnel and damage to the knowledge of the clinical picture does not allow prevent and register this type of complication. The purpose of research — the use of ultrasound in the diagnosis of the location of the n.vagus to prevent damage during puncture and catheterization IJV. In the process of intensive care at various emergencies in 100 children aged from 2 weeks to 17 years, conducted IJV ultrasound to identify anatomic relationships of the internal jugular vein, carotid artery and n.vagus . At 30 children ultrasound preceded IJV catheterization (static method) and then selecting the most safe vascular access to the IJV. Dynamic method of ultrasound guidance during IJV catheterization was performed аt 26 саses. We made a retrospective analysis of a series of stationary cards of patients in the intensive care ward with suspected damage to the vagus nerve as a result of catheterization (attempts) IJV. Results — when the preliminary ultrasoundneurovascular bundle all the children had rendered the vagus nerve. Selection of the optimal, secure access to the IJV on the basis of static methods and ultrasound assisted of catheterization allowed to successfully catheterize IJV and avoided mechanical complications, including damage of the nervus vagus. Retrospective analysis of stationary cards of patients allow to think about the presence of such complications are not recorded according to medical records. |
first_indexed | 2024-04-10T03:56:31Z |
format | Article |
id | doaj.art-c6b82f6647d840c7b35d5eeed7d85586 |
institution | Directory Open Access Journal |
issn | 2226-6704 2411-6564 |
language | Russian |
last_indexed | 2024-04-10T03:56:31Z |
publishDate | 2017-08-01 |
publisher | SINAPS LLC |
record_format | Article |
series | Архивъ внутренней медицины |
spelling | doaj.art-c6b82f6647d840c7b35d5eeed7d855862023-03-13T07:12:08ZrusSINAPS LLCАрхивъ внутренней медицины2226-67042411-65642017-08-017430631210.20514/2226-6704-2017-7-4-306-312626RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVEM. V. Bykov0V. V. Lazarev1K. S. Madorskii2V. G. Bagaev3L. V. Bykova4Российский национальный исследовательский медицинский университет им. Н.И. Пирогова, ГБУЗ «Научно-исследовательский институт неотложной детской хирургии и травматологии»Российский национальный исследовательский медицинский университет им. Н.И. ПироговаГБУЗ «Научно-исследовательский институт неотложной детской хирургии и травматологии»ГБУЗ «Научно-исследовательский институт неотложной детской хирургии и травматологии»ГБУЗ ГКБ № 13 ДЗМ, отделение реанимации и интенсивной терапии новорожденных недоношенных детейIn the course of intensive therapy for central venous catheterization is a high risk of mechanical complications. The probability of damage to the nervus vagus in the catheterization internal jugular vein is very high, but the lack of vigilance of medical personnel and damage to the knowledge of the clinical picture does not allow prevent and register this type of complication. The purpose of research — the use of ultrasound in the diagnosis of the location of the n.vagus to prevent damage during puncture and catheterization IJV. In the process of intensive care at various emergencies in 100 children aged from 2 weeks to 17 years, conducted IJV ultrasound to identify anatomic relationships of the internal jugular vein, carotid artery and n.vagus . At 30 children ultrasound preceded IJV catheterization (static method) and then selecting the most safe vascular access to the IJV. Dynamic method of ultrasound guidance during IJV catheterization was performed аt 26 саses. We made a retrospective analysis of a series of stationary cards of patients in the intensive care ward with suspected damage to the vagus nerve as a result of catheterization (attempts) IJV. Results — when the preliminary ultrasoundneurovascular bundle all the children had rendered the vagus nerve. Selection of the optimal, secure access to the IJV on the basis of static methods and ultrasound assisted of catheterization allowed to successfully catheterize IJV and avoided mechanical complications, including damage of the nervus vagus. Retrospective analysis of stationary cards of patients allow to think about the presence of such complications are not recorded according to medical records.https://www.medarhive.ru/jour/article/view/685катетеризация веныосложненияблуждающий нервинтенсивная терапия у детей |
spellingShingle | M. V. Bykov V. V. Lazarev K. S. Madorskii V. G. Bagaev L. V. Bykova RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE Архивъ внутренней медицины катетеризация вены осложнения блуждающий нерв интенсивная терапия у детей |
title | RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE |
title_full | RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE |
title_fullStr | RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE |
title_full_unstemmed | RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE |
title_short | RARELY DETECTED COMPLICATION DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN — DAMAGE TO THE VAGUS NERVE |
title_sort | rarely detected complication during catheterization of internal jugular vein damage to the vagus nerve |
topic | катетеризация вены осложнения блуждающий нерв интенсивная терапия у детей |
url | https://www.medarhive.ru/jour/article/view/685 |
work_keys_str_mv | AT mvbykov rarelydetectedcomplicationduringcatheterizationofinternaljugularveindamagetothevagusnerve AT vvlazarev rarelydetectedcomplicationduringcatheterizationofinternaljugularveindamagetothevagusnerve AT ksmadorskii rarelydetectedcomplicationduringcatheterizationofinternaljugularveindamagetothevagusnerve AT vgbagaev rarelydetectedcomplicationduringcatheterizationofinternaljugularveindamagetothevagusnerve AT lvbykova rarelydetectedcomplicationduringcatheterizationofinternaljugularveindamagetothevagusnerve |