Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments

Nowadays, fabric air duct (FAD) systems are the most cost-effective, and aesthetically appealing way to evenly distribute heated or cooled air to large open interior spaces. There is a need to develop a proper procedure to calculate the friction factor and Nusselt number of the air flow inside these...

Full description

Bibliographic Details
Main Authors: Mohamed Hekal, Wael M. El-Maghlany, Yehia A. Eldrainy, Mohammed El-Adawy
Format: Article
Language:English
Published: Elsevier 2023-07-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X23004136
_version_ 1827930488778522624
author Mohamed Hekal
Wael M. El-Maghlany
Yehia A. Eldrainy
Mohammed El-Adawy
author_facet Mohamed Hekal
Wael M. El-Maghlany
Yehia A. Eldrainy
Mohammed El-Adawy
author_sort Mohamed Hekal
collection DOAJ
description Nowadays, fabric air duct (FAD) systems are the most cost-effective, and aesthetically appealing way to evenly distribute heated or cooled air to large open interior spaces. There is a need to develop a proper procedure to calculate the friction factor and Nusselt number of the air flow inside these types of fabric air ducts because of their great impact on the design of central air conditioning systems. Therefore, the main objective of this research is to carry out laboratory and numerical experiments to establish a certain technique of calculation of the friction factor and Nusselt number inside fabric air ducts and to develop validated CFD air distribution model capable of predicting the air flow pattern and heat transfer parameters inside different configurations of fabric air ducts. By controlling these parameters, FAD systems can be balanced and designed. For this purpose, three fabric air ducts made of porous and non-porous polyester with different outlet ports distribution and have a diameter of 60 cm and a length of 3 m have been experimentally assessed under variation of inlet Reynold numbers ranging from 9.9x103 to 1.47x105. The results showed that the maximum error between laboratory and numerical values for the mean friction factor and mean Nusselt number was 4.9% and 4.8% respectively, which was within an acceptable range according to previous studies. Based on the results analysis empirical correlations were obtained for their importance in achieving a well-balanced FAD system. One of the most significant equations that were obtained in this research was the relationship between the Nusselt number and Reynold number. For porous duct was Nu=127.69Re0.148, non-porous duct 4,8 o'clock air slots was Nu=4.51Re0.49 and non-porous duct 3,9 o'clock air slots was Nu=40.82Re0.139. The relationship between friction factor with Reynold number for porous duct was f=0.251e−0.0000067Re, non-porous duct 4,8 o'clock air slots was f=0.397e−0.000017Re and non-porous duct 3,9 o'clock air slots was f=0.529e−0.000025Re. All correlations are valid only within the range of conditions considered in current experimental study.
first_indexed 2024-03-13T06:37:25Z
format Article
id doaj.art-c6db5b7c64154571aba10e91efac7775
institution Directory Open Access Journal
issn 2214-157X
language English
last_indexed 2024-03-13T06:37:25Z
publishDate 2023-07-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj.art-c6db5b7c64154571aba10e91efac77752023-06-09T04:28:07ZengElsevierCase Studies in Thermal Engineering2214-157X2023-07-0147103107Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessmentsMohamed Hekal0Wael M. El-Maghlany1Yehia A. Eldrainy2Mohammed El-Adawy3Mechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, 21544, EgyptMechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, 21544, EgyptMechanical Engineering Department, College of Engineering and Technology, Arab Academy of Science, Technology and Maritime Transport (AASTMT), 1029, Abu Kir, Alexandria, Egypt; Mechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, 21544, EgyptMechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, 21544, Egypt; Corresponding author.Nowadays, fabric air duct (FAD) systems are the most cost-effective, and aesthetically appealing way to evenly distribute heated or cooled air to large open interior spaces. There is a need to develop a proper procedure to calculate the friction factor and Nusselt number of the air flow inside these types of fabric air ducts because of their great impact on the design of central air conditioning systems. Therefore, the main objective of this research is to carry out laboratory and numerical experiments to establish a certain technique of calculation of the friction factor and Nusselt number inside fabric air ducts and to develop validated CFD air distribution model capable of predicting the air flow pattern and heat transfer parameters inside different configurations of fabric air ducts. By controlling these parameters, FAD systems can be balanced and designed. For this purpose, three fabric air ducts made of porous and non-porous polyester with different outlet ports distribution and have a diameter of 60 cm and a length of 3 m have been experimentally assessed under variation of inlet Reynold numbers ranging from 9.9x103 to 1.47x105. The results showed that the maximum error between laboratory and numerical values for the mean friction factor and mean Nusselt number was 4.9% and 4.8% respectively, which was within an acceptable range according to previous studies. Based on the results analysis empirical correlations were obtained for their importance in achieving a well-balanced FAD system. One of the most significant equations that were obtained in this research was the relationship between the Nusselt number and Reynold number. For porous duct was Nu=127.69Re0.148, non-porous duct 4,8 o'clock air slots was Nu=4.51Re0.49 and non-porous duct 3,9 o'clock air slots was Nu=40.82Re0.139. The relationship between friction factor with Reynold number for porous duct was f=0.251e−0.0000067Re, non-porous duct 4,8 o'clock air slots was f=0.397e−0.000017Re and non-porous duct 3,9 o'clock air slots was f=0.529e−0.000025Re. All correlations are valid only within the range of conditions considered in current experimental study.http://www.sciencedirect.com/science/article/pii/S2214157X23004136Fabric air ductFriction factorNusselt numberReynolds number
spellingShingle Mohamed Hekal
Wael M. El-Maghlany
Yehia A. Eldrainy
Mohammed El-Adawy
Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
Case Studies in Thermal Engineering
Fabric air duct
Friction factor
Nusselt number
Reynolds number
title Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
title_full Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
title_fullStr Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
title_full_unstemmed Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
title_short Hydro-thermal performance of fabric air duct (FAD): Experimental and CFD simulation assessments
title_sort hydro thermal performance of fabric air duct fad experimental and cfd simulation assessments
topic Fabric air duct
Friction factor
Nusselt number
Reynolds number
url http://www.sciencedirect.com/science/article/pii/S2214157X23004136
work_keys_str_mv AT mohamedhekal hydrothermalperformanceoffabricairductfadexperimentalandcfdsimulationassessments
AT waelmelmaghlany hydrothermalperformanceoffabricairductfadexperimentalandcfdsimulationassessments
AT yehiaaeldrainy hydrothermalperformanceoffabricairductfadexperimentalandcfdsimulationassessments
AT mohammedeladawy hydrothermalperformanceoffabricairductfadexperimentalandcfdsimulationassessments