Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator

Abstract Background Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding scre...

Full description

Bibliographic Details
Main Authors: Milan M Mitkovic, Nikola D Korunovic, Sasa S Milenkovic, Predrag M Stojiljkovic, Miodrag T Manic, Miroslav D Trajanovic
Format: Article
Language:English
Published: BMC 2024-04-01
Series:BMC Musculoskeletal Disorders
Subjects:
Online Access:https://doi.org/10.1186/s12891-024-07392-3
_version_ 1797209582718681088
author Milan M Mitkovic
Nikola D Korunovic
Sasa S Milenkovic
Predrag M Stojiljkovic
Miodrag T Manic
Miroslav D Trajanovic
author_facet Milan M Mitkovic
Nikola D Korunovic
Sasa S Milenkovic
Predrag M Stojiljkovic
Miodrag T Manic
Miroslav D Trajanovic
author_sort Milan M Mitkovic
collection DOAJ
description Abstract Background Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. Methods Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) – SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. Results Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. Conclusions A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.
first_indexed 2024-04-24T09:57:00Z
format Article
id doaj.art-c72bc0974e8b4637b7b9e1918c84890f
institution Directory Open Access Journal
issn 1471-2474
language English
last_indexed 2024-04-24T09:57:00Z
publishDate 2024-04-01
publisher BMC
record_format Article
series BMC Musculoskeletal Disorders
spelling doaj.art-c72bc0974e8b4637b7b9e1918c84890f2024-04-14T11:05:41ZengBMCBMC Musculoskeletal Disorders1471-24742024-04-012511710.1186/s12891-024-07392-3Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixatorMilan M Mitkovic0Nikola D Korunovic1Sasa S Milenkovic2Predrag M Stojiljkovic3Miodrag T Manic4Miroslav D Trajanovic5Clinic for Orthopaedics and Traumatology “Academician Prof. Dr. Milorad Mitkovic”, University Clinical Center NisFaculty of Mechanical Engineering, University of NisClinic for Orthopaedics and Traumatology “Academician Prof. Dr. Milorad Mitkovic”, University Clinical Center NisClinic for Orthopaedics and Traumatology “Academician Prof. Dr. Milorad Mitkovic”, University Clinical Center NisFaculty of Mechanical Engineering, University of NisFaculty of Mechanical Engineering, University of NisAbstract Background Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. Methods Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) – SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. Results Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. Conclusions A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.https://doi.org/10.1186/s12891-024-07392-3DynamizationLag screwPertrochanteric fractureGait
spellingShingle Milan M Mitkovic
Nikola D Korunovic
Sasa S Milenkovic
Predrag M Stojiljkovic
Miodrag T Manic
Miroslav D Trajanovic
Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
BMC Musculoskeletal Disorders
Dynamization
Lag screw
Pertrochanteric fracture
Gait
title Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
title_full Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
title_fullStr Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
title_full_unstemmed Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
title_short Forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
title_sort forces required to dynamize sliding screws in gamma nail and selfdynamizable internal fixator
topic Dynamization
Lag screw
Pertrochanteric fracture
Gait
url https://doi.org/10.1186/s12891-024-07392-3
work_keys_str_mv AT milanmmitkovic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator
AT nikoladkorunovic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator
AT sasasmilenkovic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator
AT predragmstojiljkovic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator
AT miodragtmanic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator
AT miroslavdtrajanovic forcesrequiredtodynamizeslidingscrewsingammanailandselfdynamizableinternalfixator