Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv)
<b>Objective</b>: To develop a Spanish version of the international Hip Outcome Tool questionnaire (iHOT-12Sv) for assessing the psychometric characteristics (internal consistency, convergent validity, test–retest reliability, and floor and ceiling effects) of this version in physically...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-10-01
|
Series: | Journal of Clinical Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2077-0383/11/21/6232 |
_version_ | 1797467810691022848 |
---|---|
author | Ángel González-de-la-Flor Ibai López-de-Uralde-Villanueva Juan Antonio Valera-Calero Jaime Almazán-Polo José Javier López-Marcos César Fernández-de-las-Peñas Pablo García-Fernández Gustavo Plaza-Manzano |
author_facet | Ángel González-de-la-Flor Ibai López-de-Uralde-Villanueva Juan Antonio Valera-Calero Jaime Almazán-Polo José Javier López-Marcos César Fernández-de-las-Peñas Pablo García-Fernández Gustavo Plaza-Manzano |
author_sort | Ángel González-de-la-Flor |
collection | DOAJ |
description | <b>Objective</b>: To develop a Spanish version of the international Hip Outcome Tool questionnaire (iHOT-12Sv) for assessing the psychometric characteristics (internal consistency, convergent validity, test–retest reliability, and floor and ceiling effects) of this version in physically active patients with hip pain. <b>Methods</b>: After conducting the translation and transcultural adaptation, a consecutive sample of patients with labral tear injury and/or femoroacetabular impingement (Pincer or Cam type) were recruited in a Spanish Hospital. Patients completed the iHOT-12Sv and the Spanish version of the iHOT-33 and the Hip Outcome Score (HOS). Internal consistency was calculated using Cronbach’s alpha; convergent validity was evaluated using Spearman correlation coefficients (Rho) with iHOT-33 and HOS; test–retest reliability was examined using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable changes (MDC); and floor and ceiling effects were calculated as the percentage of patients who obtained the minimum and maximum score. <b>Results</b>: One hundred and fifty-three patients (64.7% males) participated in this study. Cronbach’s alpha of 0.92 revealed the excellent internal consistency. In addition, the iHOT-12Sv demonstrated strong to very strong correlations with the HOS (Rho ranged from 0.741 to 0.827; <i>p</i> < 0.001) and the iHOT-33 (Rho = 0.932; <i>p</i> < 0.001), respectively; acceptable test-retest reliability (ICC = 0.86 to 0.94); SEM = 6.21 and MDC = 17.22; and no floor or ceiling effects were found. <b>Conclusions</b>: The iHOT-12Sv can be used as a valid and reliable tool for clinical evaluation of physically active patients with hip pathology. However, the full version is preferable for research purposes aiming to assess changes in hip function. |
first_indexed | 2024-03-09T18:59:00Z |
format | Article |
id | doaj.art-c74c7b37c11a4fedb70ca01cfafa51fe |
institution | Directory Open Access Journal |
issn | 2077-0383 |
language | English |
last_indexed | 2024-03-09T18:59:00Z |
publishDate | 2022-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Journal of Clinical Medicine |
spelling | doaj.art-c74c7b37c11a4fedb70ca01cfafa51fe2023-11-24T05:14:26ZengMDPI AGJournal of Clinical Medicine2077-03832022-10-011121623210.3390/jcm11216232Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv)Ángel González-de-la-Flor0Ibai López-de-Uralde-Villanueva1Juan Antonio Valera-Calero2Jaime Almazán-Polo3José Javier López-Marcos4César Fernández-de-las-Peñas5Pablo García-Fernández6Gustavo Plaza-Manzano7Department of Physical Therapy and Sport Medicine, Hospital Universitario Quironsalud Madrid, 28223 Madrid, SpainDepartment of Radiology, Rehabilitation and Physiotherapy, Universidad Complutense de Madrid, 28040 Madrid, SpainVALTRADOFI Research Group, Department of Physiotherapy, Faculty of Health, Universidad Camilo José Cela, 28692 Villanueva de la Cañada, SpainFaculty of Sport Sciences, Universidad Europea de Madrid, 28670 Madrid, SpainDepartment of Radiology, Rehabilitation and Physiotherapy, Universidad Complutense de Madrid, 28040 Madrid, SpainDepartment of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Universidad Rey Juan Carlos, 28922 Alcorcón, SpainDepartment of Radiology, Rehabilitation and Physiotherapy, Universidad Complutense de Madrid, 28040 Madrid, SpainDepartment of Radiology, Rehabilitation and Physiotherapy, Universidad Complutense de Madrid, 28040 Madrid, Spain<b>Objective</b>: To develop a Spanish version of the international Hip Outcome Tool questionnaire (iHOT-12Sv) for assessing the psychometric characteristics (internal consistency, convergent validity, test–retest reliability, and floor and ceiling effects) of this version in physically active patients with hip pain. <b>Methods</b>: After conducting the translation and transcultural adaptation, a consecutive sample of patients with labral tear injury and/or femoroacetabular impingement (Pincer or Cam type) were recruited in a Spanish Hospital. Patients completed the iHOT-12Sv and the Spanish version of the iHOT-33 and the Hip Outcome Score (HOS). Internal consistency was calculated using Cronbach’s alpha; convergent validity was evaluated using Spearman correlation coefficients (Rho) with iHOT-33 and HOS; test–retest reliability was examined using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable changes (MDC); and floor and ceiling effects were calculated as the percentage of patients who obtained the minimum and maximum score. <b>Results</b>: One hundred and fifty-three patients (64.7% males) participated in this study. Cronbach’s alpha of 0.92 revealed the excellent internal consistency. In addition, the iHOT-12Sv demonstrated strong to very strong correlations with the HOS (Rho ranged from 0.741 to 0.827; <i>p</i> < 0.001) and the iHOT-33 (Rho = 0.932; <i>p</i> < 0.001), respectively; acceptable test-retest reliability (ICC = 0.86 to 0.94); SEM = 6.21 and MDC = 17.22; and no floor or ceiling effects were found. <b>Conclusions</b>: The iHOT-12Sv can be used as a valid and reliable tool for clinical evaluation of physically active patients with hip pathology. However, the full version is preferable for research purposes aiming to assess changes in hip function.https://www.mdpi.com/2077-0383/11/21/6232clinimetricsfunctionhipoutcome measuresvalidityreliability |
spellingShingle | Ángel González-de-la-Flor Ibai López-de-Uralde-Villanueva Juan Antonio Valera-Calero Jaime Almazán-Polo José Javier López-Marcos César Fernández-de-las-Peñas Pablo García-Fernández Gustavo Plaza-Manzano Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) Journal of Clinical Medicine clinimetrics function hip outcome measures validity reliability |
title | Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) |
title_full | Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) |
title_fullStr | Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) |
title_full_unstemmed | Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) |
title_short | Validity and Test–Retest Reliability of the Spanish Version of the International Hip Outcome Tool (iHOT-12Sv) |
title_sort | validity and test retest reliability of the spanish version of the international hip outcome tool ihot 12sv |
topic | clinimetrics function hip outcome measures validity reliability |
url | https://www.mdpi.com/2077-0383/11/21/6232 |
work_keys_str_mv | AT angelgonzalezdelaflor validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT ibailopezdeuraldevillanueva validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT juanantoniovaleracalero validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT jaimealmazanpolo validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT josejavierlopezmarcos validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT cesarfernandezdelaspenas validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT pablogarciafernandez validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv AT gustavoplazamanzano validityandtestretestreliabilityofthespanishversionoftheinternationalhipoutcometoolihot12sv |