A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity

In view of problem that correctness of protection polarity cannot be determined since new power plant cannot provide enough load to general test instrument, the paper proposed a new method of applying waveform record of starting load to analyze protection polarity. The method uses time relation of w...

Full description

Bibliographic Details
Main Authors: LV Bin, NI Sai-sai, ZHANG Jie-shang, WANG Wan-li, GAO Bao-long
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2012-06-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/id/8423
_version_ 1797868523021664256
author LV Bin
NI Sai-sai
ZHANG Jie-shang
WANG Wan-li
GAO Bao-long
author_facet LV Bin
NI Sai-sai
ZHANG Jie-shang
WANG Wan-li
GAO Bao-long
author_sort LV Bin
collection DOAJ
description In view of problem that correctness of protection polarity cannot be determined since new power plant cannot provide enough load to general test instrument, the paper proposed a new method of applying waveform record of starting load to analyze protection polarity. The method uses time relation of waveform record to deduce angle relation of electric variables, namely converting time difference calibrated by waveform record of peak of voltage and current to phase angle, so as to judge correctness of protection polarity. The test result showed that the method is simple and practical.
first_indexed 2024-04-09T23:58:20Z
format Article
id doaj.art-c754c89d51ec465ea91f107a6fdccc71
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-09T23:58:20Z
publishDate 2012-06-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-c754c89d51ec465ea91f107a6fdccc712023-03-17T02:02:11ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2012-06-013865861A New Method of Applying Waveform Record of Starting Load to Analyze Protection PolarityLV Bin0NI Sai-sai1ZHANG Jie-shangWANG Wan-liGAO Bao-long1.Gansu Electric Power Science Research Institute, Lanzhou 730050, China. 2.Ningxia Datang International Daba Power Generation Co., Ltd., Yinchuan 750001, China. 3.Baiyin Repair District of Lanzhou Ex1.Gansu Electric Power Science Research Institute, Lanzhou 730050, China. 2.Ningxia Datang International Daba Power Generation Co., Ltd., Yinchuan 750001, China. 3.Baiyin Repair District of Lanzhou ExIn view of problem that correctness of protection polarity cannot be determined since new power plant cannot provide enough load to general test instrument, the paper proposed a new method of applying waveform record of starting load to analyze protection polarity. The method uses time relation of waveform record to deduce angle relation of electric variables, namely converting time difference calibrated by waveform record of peak of voltage and current to phase angle, so as to judge correctness of protection polarity. The test result showed that the method is simple and practical.http://www.gkzdh.cn/article/id/8423thermal power plant, starting load, light load, protection polarity, waveform record, time difference, phase angle
spellingShingle LV Bin
NI Sai-sai
ZHANG Jie-shang
WANG Wan-li
GAO Bao-long
A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
Gong-kuang zidonghua
thermal power plant, starting load, light load, protection polarity, waveform record, time difference, phase angle
title A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
title_full A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
title_fullStr A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
title_full_unstemmed A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
title_short A New Method of Applying Waveform Record of Starting Load to Analyze Protection Polarity
title_sort new method of applying waveform record of starting load to analyze protection polarity
topic thermal power plant, starting load, light load, protection polarity, waveform record, time difference, phase angle
url http://www.gkzdh.cn/article/id/8423
work_keys_str_mv AT lvbin anewmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT nisaisai anewmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT zhangjieshang anewmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT wangwanli anewmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT gaobaolong anewmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT lvbin newmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT nisaisai newmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT zhangjieshang newmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT wangwanli newmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity
AT gaobaolong newmethodofapplyingwaveformrecordofstartingloadtoanalyzeprotectionpolarity