Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods

The hygroscopic properties of atmospheric aerosols are highly relevant for the quantification of radiative effects in the atmosphere, but also of interest for the assessment of particle health effects upon inhalation. This article reports measurements of aerosol particle hygroscopicity in the highly...

Full description

Bibliographic Details
Main Authors: J. Meier, B. Wehner, A. Massling, W. Birmili, A. Nowak, T. Gnauk, E. Brüggemann, H. Herrmann, H. Min, A. Wiedensohler
Format: Article
Language:English
Published: Copernicus Publications 2009-09-01
Series:Atmospheric Chemistry and Physics
Online Access:http://www.atmos-chem-phys.net/9/6865/2009/acp-9-6865-2009.pdf
_version_ 1818787154018435072
author J. Meier
B. Wehner
A. Massling
W. Birmili
A. Nowak
T. Gnauk
E. Brüggemann
H. Herrmann
H. Min
A. Wiedensohler
author_facet J. Meier
B. Wehner
A. Massling
W. Birmili
A. Nowak
T. Gnauk
E. Brüggemann
H. Herrmann
H. Min
A. Wiedensohler
author_sort J. Meier
collection DOAJ
description The hygroscopic properties of atmospheric aerosols are highly relevant for the quantification of radiative effects in the atmosphere, but also of interest for the assessment of particle health effects upon inhalation. This article reports measurements of aerosol particle hygroscopicity in the highly polluted urban atmosphere of Beijing, China in January 2005. The meteorological conditions corresponded to a relatively cold and dry atmosphere. Three different methods were used: 1) A combination of Humidifying Differential Mobility Particle Sizer (H-DMPS) and Twin Differential Mobility Particle Sizer (TDMPS) measurements, 2) A Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA), and 3) A simplistic solubility model fed by chemical particle composition determined from Micro Orifice Uniform Deposit Impactor (MOUDI) samples. From the H-DMPS and TDMPS particle number size distributions, a size-resolved descriptive hygroscopic growth factor (DHGF) was determined for the relative humidities (RH) 55%, 77% and 90%, and particle diameters between 30 and 400 nm. In Beijing, the highest DHGFs were observed for accumulation mode particles, 1.40 (±0.03) at 90% RH. DHGF decreased significantly with particle size, reaching 1.04 (±0.15) at 30 nm. H-TDMA data also suggest a decrease in growth factor towards the biggest particles investigated (350 nm), associated with an increasing fraction of nearly hydrophobic particles. The agreement between the H-DMPS/TDMPS and H-TDMA methods was satisfactory in the accumulation mode size range (100–400 nm). In the Aitken mode range (<100 nm), the H-DMPS/TDMPS method yielded growth factors lower by up to 0.1 at 90% RH. The application of the solubility model based on measured chemical composition clearly reproduced the size-dependent trend in hygroscopic particle growth observed by the other methods. In the case of aerosol dominated by inorganic ions, the composition-derived growth factors tended to agree (± 0.05) or underestimate (up to 0.1) the values measured by the other two methods. In the case of aerosol dominated by organics, the reverse was true, with an overestimation of up to 0.2. The results shed light on the experimental and methodological uncertainties that are still connected with the determination of hygroscopic growth factors.
first_indexed 2024-12-18T14:03:15Z
format Article
id doaj.art-c76d4640d0dd4a1c8bbc0b68234c4d99
institution Directory Open Access Journal
issn 1680-7316
1680-7324
language English
last_indexed 2024-12-18T14:03:15Z
publishDate 2009-09-01
publisher Copernicus Publications
record_format Article
series Atmospheric Chemistry and Physics
spelling doaj.art-c76d4640d0dd4a1c8bbc0b68234c4d992022-12-21T21:05:19ZengCopernicus PublicationsAtmospheric Chemistry and Physics1680-73161680-73242009-09-0191868656880Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methodsJ. MeierB. WehnerA. MasslingW. BirmiliA. NowakT. GnaukE. BrüggemannH. HerrmannH. MinA. WiedensohlerThe hygroscopic properties of atmospheric aerosols are highly relevant for the quantification of radiative effects in the atmosphere, but also of interest for the assessment of particle health effects upon inhalation. This article reports measurements of aerosol particle hygroscopicity in the highly polluted urban atmosphere of Beijing, China in January 2005. The meteorological conditions corresponded to a relatively cold and dry atmosphere. Three different methods were used: 1) A combination of Humidifying Differential Mobility Particle Sizer (H-DMPS) and Twin Differential Mobility Particle Sizer (TDMPS) measurements, 2) A Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA), and 3) A simplistic solubility model fed by chemical particle composition determined from Micro Orifice Uniform Deposit Impactor (MOUDI) samples. From the H-DMPS and TDMPS particle number size distributions, a size-resolved descriptive hygroscopic growth factor (DHGF) was determined for the relative humidities (RH) 55%, 77% and 90%, and particle diameters between 30 and 400 nm. In Beijing, the highest DHGFs were observed for accumulation mode particles, 1.40 (±0.03) at 90% RH. DHGF decreased significantly with particle size, reaching 1.04 (±0.15) at 30 nm. H-TDMA data also suggest a decrease in growth factor towards the biggest particles investigated (350 nm), associated with an increasing fraction of nearly hydrophobic particles. The agreement between the H-DMPS/TDMPS and H-TDMA methods was satisfactory in the accumulation mode size range (100–400 nm). In the Aitken mode range (<100 nm), the H-DMPS/TDMPS method yielded growth factors lower by up to 0.1 at 90% RH. The application of the solubility model based on measured chemical composition clearly reproduced the size-dependent trend in hygroscopic particle growth observed by the other methods. In the case of aerosol dominated by inorganic ions, the composition-derived growth factors tended to agree (± 0.05) or underestimate (up to 0.1) the values measured by the other two methods. In the case of aerosol dominated by organics, the reverse was true, with an overestimation of up to 0.2. The results shed light on the experimental and methodological uncertainties that are still connected with the determination of hygroscopic growth factors.http://www.atmos-chem-phys.net/9/6865/2009/acp-9-6865-2009.pdf
spellingShingle J. Meier
B. Wehner
A. Massling
W. Birmili
A. Nowak
T. Gnauk
E. Brüggemann
H. Herrmann
H. Min
A. Wiedensohler
Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
Atmospheric Chemistry and Physics
title Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
title_full Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
title_fullStr Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
title_full_unstemmed Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
title_short Hygroscopic growth of urban aerosol particles in Beijing (China) during wintertime: a comparison of three experimental methods
title_sort hygroscopic growth of urban aerosol particles in beijing china during wintertime a comparison of three experimental methods
url http://www.atmos-chem-phys.net/9/6865/2009/acp-9-6865-2009.pdf
work_keys_str_mv AT jmeier hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT bwehner hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT amassling hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT wbirmili hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT anowak hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT tgnauk hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT ebruggemann hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT hherrmann hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT hmin hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods
AT awiedensohler hygroscopicgrowthofurbanaerosolparticlesinbeijingchinaduringwintertimeacomparisonofthreeexperimentalmethods