Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability

Abstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properti...

Full description

Bibliographic Details
Main Authors: Fabiana Amaral de Carvalho, Letícia Cristina Carvalho Silva, Regina Adriana Nogueira, Stella Maria Cândido Camargos, Andressa Silva, Viviane Santos Borges
Format: Article
Language:English
Published: Editora Champagnat
Series:Fisioterapia em Movimento
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=en
_version_ 1818040117343813632
author Fabiana Amaral de Carvalho
Letícia Cristina Carvalho Silva
Regina Adriana Nogueira
Stella Maria Cândido Camargos
Andressa Silva
Viviane Santos Borges
author_facet Fabiana Amaral de Carvalho
Letícia Cristina Carvalho Silva
Regina Adriana Nogueira
Stella Maria Cândido Camargos
Andressa Silva
Viviane Santos Borges
author_sort Fabiana Amaral de Carvalho
collection DOAJ
description Abstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properties of this instrument for this purpose, have not been investigated. Objective: To investigate the concurrent criterion validity, test-retest and inter-rater reliabilities of the aneroid sphygmomanometer test (AST) without modification, for assessment of the strength of subjects with lower limb amputations. Methods: Twenty-two subjects (57.6 ± 15.2 years) with lower limb amputations were included in this study. Maximum isometric force was assessed with a handheld dynamometer (microFet2®) and the AST. To identify differences between trials, one-way ANOVA was applied. To assess the concurrent criterion validity, test-retest and inter-rater reliabilities of the AST, Pearson’s correlation coefficients of determination and intra-class correlation coefficient (ICC) were calculated. Results: For all muscle groups, no differences were observed between the trials (0.00001 ≤ F ≤ 0.10; 0.90 ≤ p ≤ 0.99). Significant, positive, and high to very high correlations were found between the HHD and the AST measures for the different numbers of trials for all assessed muscles (0.76 ≤ r ≤ 0.93; p ≤ 0.02). Test-retest (0.67 ≤ ICC ≤ 0.97) and inter-rater reliabilities (0.78 ≤ ICC ≤ 0.97) were adequate. The values obtained with the AST were good predictors of those obtained with HHD (0.58 ≤ r2 ≤ 0.85). Conclusion: For individuals with lower limb amputation, the AST showed adequate concurrent criterion validity, test-retest reliability and inter-rater reliability for the assessment of lower limbs muscle strength.
first_indexed 2024-12-10T08:09:26Z
format Article
id doaj.art-c7799c9c107a4be8bd6499ff532d808b
institution Directory Open Access Journal
issn 1980-5918
language English
last_indexed 2024-12-10T08:09:26Z
publisher Editora Champagnat
record_format Article
series Fisioterapia em Movimento
spelling doaj.art-c7799c9c107a4be8bd6499ff532d808b2022-12-22T01:56:37ZengEditora ChampagnatFisioterapia em Movimento1980-591830suppl 113915010.1590/1980-5918.030.s01.ao14S0103-51502017000500139Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliabilityFabiana Amaral de CarvalhoLetícia Cristina Carvalho SilvaRegina Adriana NogueiraStella Maria Cândido CamargosAndressa SilvaViviane Santos BorgesAbstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properties of this instrument for this purpose, have not been investigated. Objective: To investigate the concurrent criterion validity, test-retest and inter-rater reliabilities of the aneroid sphygmomanometer test (AST) without modification, for assessment of the strength of subjects with lower limb amputations. Methods: Twenty-two subjects (57.6 ± 15.2 years) with lower limb amputations were included in this study. Maximum isometric force was assessed with a handheld dynamometer (microFet2®) and the AST. To identify differences between trials, one-way ANOVA was applied. To assess the concurrent criterion validity, test-retest and inter-rater reliabilities of the AST, Pearson’s correlation coefficients of determination and intra-class correlation coefficient (ICC) were calculated. Results: For all muscle groups, no differences were observed between the trials (0.00001 ≤ F ≤ 0.10; 0.90 ≤ p ≤ 0.99). Significant, positive, and high to very high correlations were found between the HHD and the AST measures for the different numbers of trials for all assessed muscles (0.76 ≤ r ≤ 0.93; p ≤ 0.02). Test-retest (0.67 ≤ ICC ≤ 0.97) and inter-rater reliabilities (0.78 ≤ ICC ≤ 0.97) were adequate. The values obtained with the AST were good predictors of those obtained with HHD (0.58 ≤ r2 ≤ 0.85). Conclusion: For individuals with lower limb amputation, the AST showed adequate concurrent criterion validity, test-retest reliability and inter-rater reliability for the assessment of lower limbs muscle strength.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=enEsfigmomanômetroAmputaçãoConfiabilidade dos DadosForça MuscularValidade dos Testes
spellingShingle Fabiana Amaral de Carvalho
Letícia Cristina Carvalho Silva
Regina Adriana Nogueira
Stella Maria Cândido Camargos
Andressa Silva
Viviane Santos Borges
Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
Fisioterapia em Movimento
Esfigmomanômetro
Amputação
Confiabilidade dos Dados
Força Muscular
Validade dos Testes
title Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
title_full Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
title_fullStr Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
title_full_unstemmed Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
title_short Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
title_sort sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation validity and reliability
topic Esfigmomanômetro
Amputação
Confiabilidade dos Dados
Força Muscular
Validade dos Testes
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=en
work_keys_str_mv AT fabianaamaraldecarvalho sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability
AT leticiacristinacarvalhosilva sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability
AT reginaadriananogueira sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability
AT stellamariacandidocamargos sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability
AT andressasilva sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability
AT vivianesantosborges sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability