Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability
Abstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properti...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Editora Champagnat
|
Series: | Fisioterapia em Movimento |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=en |
_version_ | 1818040117343813632 |
---|---|
author | Fabiana Amaral de Carvalho Letícia Cristina Carvalho Silva Regina Adriana Nogueira Stella Maria Cândido Camargos Andressa Silva Viviane Santos Borges |
author_facet | Fabiana Amaral de Carvalho Letícia Cristina Carvalho Silva Regina Adriana Nogueira Stella Maria Cândido Camargos Andressa Silva Viviane Santos Borges |
author_sort | Fabiana Amaral de Carvalho |
collection | DOAJ |
description | Abstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properties of this instrument for this purpose, have not been investigated. Objective: To investigate the concurrent criterion validity, test-retest and inter-rater reliabilities of the aneroid sphygmomanometer test (AST) without modification, for assessment of the strength of subjects with lower limb amputations. Methods: Twenty-two subjects (57.6 ± 15.2 years) with lower limb amputations were included in this study. Maximum isometric force was assessed with a handheld dynamometer (microFet2®) and the AST. To identify differences between trials, one-way ANOVA was applied. To assess the concurrent criterion validity, test-retest and inter-rater reliabilities of the AST, Pearson’s correlation coefficients of determination and intra-class correlation coefficient (ICC) were calculated. Results: For all muscle groups, no differences were observed between the trials (0.00001 ≤ F ≤ 0.10; 0.90 ≤ p ≤ 0.99). Significant, positive, and high to very high correlations were found between the HHD and the AST measures for the different numbers of trials for all assessed muscles (0.76 ≤ r ≤ 0.93; p ≤ 0.02). Test-retest (0.67 ≤ ICC ≤ 0.97) and inter-rater reliabilities (0.78 ≤ ICC ≤ 0.97) were adequate. The values obtained with the AST were good predictors of those obtained with HHD (0.58 ≤ r2 ≤ 0.85). Conclusion: For individuals with lower limb amputation, the AST showed adequate concurrent criterion validity, test-retest reliability and inter-rater reliability for the assessment of lower limbs muscle strength. |
first_indexed | 2024-12-10T08:09:26Z |
format | Article |
id | doaj.art-c7799c9c107a4be8bd6499ff532d808b |
institution | Directory Open Access Journal |
issn | 1980-5918 |
language | English |
last_indexed | 2024-12-10T08:09:26Z |
publisher | Editora Champagnat |
record_format | Article |
series | Fisioterapia em Movimento |
spelling | doaj.art-c7799c9c107a4be8bd6499ff532d808b2022-12-22T01:56:37ZengEditora ChampagnatFisioterapia em Movimento1980-591830suppl 113915010.1590/1980-5918.030.s01.ao14S0103-51502017000500139Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliabilityFabiana Amaral de CarvalhoLetícia Cristina Carvalho SilvaRegina Adriana NogueiraStella Maria Cândido CamargosAndressa SilvaViviane Santos BorgesAbstract Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properties of this instrument for this purpose, have not been investigated. Objective: To investigate the concurrent criterion validity, test-retest and inter-rater reliabilities of the aneroid sphygmomanometer test (AST) without modification, for assessment of the strength of subjects with lower limb amputations. Methods: Twenty-two subjects (57.6 ± 15.2 years) with lower limb amputations were included in this study. Maximum isometric force was assessed with a handheld dynamometer (microFet2®) and the AST. To identify differences between trials, one-way ANOVA was applied. To assess the concurrent criterion validity, test-retest and inter-rater reliabilities of the AST, Pearson’s correlation coefficients of determination and intra-class correlation coefficient (ICC) were calculated. Results: For all muscle groups, no differences were observed between the trials (0.00001 ≤ F ≤ 0.10; 0.90 ≤ p ≤ 0.99). Significant, positive, and high to very high correlations were found between the HHD and the AST measures for the different numbers of trials for all assessed muscles (0.76 ≤ r ≤ 0.93; p ≤ 0.02). Test-retest (0.67 ≤ ICC ≤ 0.97) and inter-rater reliabilities (0.78 ≤ ICC ≤ 0.97) were adequate. The values obtained with the AST were good predictors of those obtained with HHD (0.58 ≤ r2 ≤ 0.85). Conclusion: For individuals with lower limb amputation, the AST showed adequate concurrent criterion validity, test-retest reliability and inter-rater reliability for the assessment of lower limbs muscle strength.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=enEsfigmomanômetroAmputaçãoConfiabilidade dos DadosForça MuscularValidade dos Testes |
spellingShingle | Fabiana Amaral de Carvalho Letícia Cristina Carvalho Silva Regina Adriana Nogueira Stella Maria Cândido Camargos Andressa Silva Viviane Santos Borges Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability Fisioterapia em Movimento Esfigmomanômetro Amputação Confiabilidade dos Dados Força Muscular Validade dos Testes |
title | Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability |
title_full | Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability |
title_fullStr | Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability |
title_full_unstemmed | Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability |
title_short | Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability |
title_sort | sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation validity and reliability |
topic | Esfigmomanômetro Amputação Confiabilidade dos Dados Força Muscular Validade dos Testes |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-51502017000500139&lng=en&tlng=en |
work_keys_str_mv | AT fabianaamaraldecarvalho sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability AT leticiacristinacarvalhosilva sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability AT reginaadriananogueira sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability AT stellamariacandidocamargos sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability AT andressasilva sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability AT vivianesantosborges sphygmomanometertesttoevaluatemusclestrengthinindividualswithlowerlimbamputationvalidityandreliability |