Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma

AIM: To study the optical coherence tomography(OCT)treatment of optic fiber thickness in patients with high myopia combined with glaucoma.<p>METHODS: Totally 160 eyes of 80 patients with high myopia and glaucoma who were treated in our hospital during 2017-01/12 were selected as the observatio...

Full description

Bibliographic Details
Main Authors: Xiao-Dan Wei, Rong Liu, Ya-Ping Gan, Xue-Mei Wang, Jian-Mei Lyu, Li-Zhen Jin, Qing-Li Kong
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2020-02-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2020/2/202002036.pdf
_version_ 1818134118030901248
author Xiao-Dan Wei
Rong Liu
Ya-Ping Gan
Xue-Mei Wang
Jian-Mei Lyu
Li-Zhen Jin
Qing-Li Kong
author_facet Xiao-Dan Wei
Rong Liu
Ya-Ping Gan
Xue-Mei Wang
Jian-Mei Lyu
Li-Zhen Jin
Qing-Li Kong
author_sort Xiao-Dan Wei
collection DOAJ
description AIM: To study the optical coherence tomography(OCT)treatment of optic fiber thickness in patients with high myopia combined with glaucoma.<p>METHODS: Totally 160 eyes of 80 patients with high myopia and glaucoma who were treated in our hospital during 2017-01/12 were selected as the observation group, and 60 healthy volunteers(120 eyes)who underwent physical examination in our hospital during the same period were selected as the control group. OCT was used to analyze the thickness of optic nerve fibers in both groups.<p>RESULTS: Subjects compared with control group, the observation group of patients with nasal side, temporal, under the nose, nasal, under the temporal and the week on the average thickness of the optic nerve fiber layer is reduced, and the temporal side nerve fiber layer thickness increased(<i>P</i><0.05), and in the observation group diopter -10.00 to -11.00D in patients with nasal side, temporal, under the nose, nose, and the temporal and the week, on average, the optic nerve fiber layer thickness were significantly higher than that of diopter≥-12.00D patients(<i>P</i><0.05). Spearman correlation analysis results showed that the absolute value of diopter was negatively correlated with the mean thickness of optic nerve fiber layer in the nasal side, upper temporal quadrant, lower nasal side, upper nasal side, lower temporal and the whole circumference, and positively correlated with the thickness of optic nerve fiber layer in the lateral temporal optic nerve.<p>CONCLUSION: In patients with high myopia combined with glaucoma, the optic nerve fibers in all quadrants except the temporal side become thinner.
first_indexed 2024-12-11T09:03:32Z
format Article
id doaj.art-c7ad3cbd96a2472f828dc3e1a1380423
institution Directory Open Access Journal
issn 1672-5123
1672-5123
language English
last_indexed 2024-12-11T09:03:32Z
publishDate 2020-02-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-c7ad3cbd96a2472f828dc3e1a13804232022-12-22T01:13:42ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232020-02-0120234334510.3980/j.issn.1672-5123.2020.2.36Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucomaXiao-Dan Wei0Rong Liu1Ya-Ping Gan2Xue-Mei Wang3Jian-Mei Lyu4Li-Zhen Jin5Qing-Li Kong6Department of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaDepartment of Ophthalmology, Tangshan Workers Hospital, Tangshan 064300, Hebei Province, ChinaAIM: To study the optical coherence tomography(OCT)treatment of optic fiber thickness in patients with high myopia combined with glaucoma.<p>METHODS: Totally 160 eyes of 80 patients with high myopia and glaucoma who were treated in our hospital during 2017-01/12 were selected as the observation group, and 60 healthy volunteers(120 eyes)who underwent physical examination in our hospital during the same period were selected as the control group. OCT was used to analyze the thickness of optic nerve fibers in both groups.<p>RESULTS: Subjects compared with control group, the observation group of patients with nasal side, temporal, under the nose, nasal, under the temporal and the week on the average thickness of the optic nerve fiber layer is reduced, and the temporal side nerve fiber layer thickness increased(<i>P</i><0.05), and in the observation group diopter -10.00 to -11.00D in patients with nasal side, temporal, under the nose, nose, and the temporal and the week, on average, the optic nerve fiber layer thickness were significantly higher than that of diopter≥-12.00D patients(<i>P</i><0.05). Spearman correlation analysis results showed that the absolute value of diopter was negatively correlated with the mean thickness of optic nerve fiber layer in the nasal side, upper temporal quadrant, lower nasal side, upper nasal side, lower temporal and the whole circumference, and positively correlated with the thickness of optic nerve fiber layer in the lateral temporal optic nerve.<p>CONCLUSION: In patients with high myopia combined with glaucoma, the optic nerve fibers in all quadrants except the temporal side become thinner.http://ies.ijo.cn/cn_publish/2020/2/202002036.pdfhigh myopiaglaucomaoptical coherence tomographyoptic nervefiber thickness
spellingShingle Xiao-Dan Wei
Rong Liu
Ya-Ping Gan
Xue-Mei Wang
Jian-Mei Lyu
Li-Zhen Jin
Qing-Li Kong
Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
Guoji Yanke Zazhi
high myopia
glaucoma
optical coherence tomography
optic nerve
fiber thickness
title Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
title_full Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
title_fullStr Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
title_full_unstemmed Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
title_short Analysis of the OCT treatment of optic fiber thickness in patients with high myopia combined with glaucoma
title_sort analysis of the oct treatment of optic fiber thickness in patients with high myopia combined with glaucoma
topic high myopia
glaucoma
optical coherence tomography
optic nerve
fiber thickness
url http://ies.ijo.cn/cn_publish/2020/2/202002036.pdf
work_keys_str_mv AT xiaodanwei analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT rongliu analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT yapinggan analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT xuemeiwang analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT jianmeilyu analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT lizhenjin analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma
AT qinglikong analysisoftheocttreatmentofopticfiberthicknessinpatientswithhighmyopiacombinedwithglaucoma