ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient sa...

Full description

Bibliographic Details
Main Authors: Rodolfo Patussi Correia, Laiz Cameirão Bento, Ana Carolina Apelle Bortolucci, Anderson Marega Alexandre, Andressa da Costa Vaz, Daniela Schimidell, Eduardo de Carvalho Pedro, Fabricio Simões Perin, Sonia Tsukasa Nozawa, Cláudio Ernesto Albers Mendes, Rodrigo de Souza Barroso, Nydia Strachman Bacal
Format: Article
Language:English
Published: Instituto Israelita de Ensino e Pesquisa Albert Einstein
Series:Einstein (São Paulo)
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000300366&lng=en&tlng=en
_version_ 1818175813662539776
author Rodolfo Patussi Correia
Laiz Cameirão Bento
Ana Carolina Apelle Bortolucci
Anderson Marega Alexandre
Andressa da Costa Vaz
Daniela Schimidell
Eduardo de Carvalho Pedro
Fabricio Simões Perin
Sonia Tsukasa Nozawa
Cláudio Ernesto Albers Mendes
Rodrigo de Souza Barroso
Nydia Strachman Bacal
author_facet Rodolfo Patussi Correia
Laiz Cameirão Bento
Ana Carolina Apelle Bortolucci
Anderson Marega Alexandre
Andressa da Costa Vaz
Daniela Schimidell
Eduardo de Carvalho Pedro
Fabricio Simões Perin
Sonia Tsukasa Nozawa
Cláudio Ernesto Albers Mendes
Rodrigo de Souza Barroso
Nydia Strachman Bacal
author_sort Rodolfo Patussi Correia
collection DOAJ
description ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones.
first_indexed 2024-12-11T20:06:16Z
format Article
id doaj.art-c801e872fcbc4ddeb609a917f935c502
institution Directory Open Access Journal
issn 2317-6385
language English
last_indexed 2024-12-11T20:06:16Z
publisher Instituto Israelita de Ensino e Pesquisa Albert Einstein
record_format Article
series Einstein (São Paulo)
spelling doaj.art-c801e872fcbc4ddeb609a917f935c5022022-12-22T00:52:24ZengInstituto Israelita de Ensino e Pesquisa Albert EinsteinEinstein (São Paulo)2317-638514336637310.1590/S1679-45082016AO3641S1679-45082016000300366Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuriaRodolfo Patussi CorreiaLaiz Cameirão BentoAna Carolina Apelle BortolucciAnderson Marega AlexandreAndressa da Costa VazDaniela SchimidellEduardo de Carvalho PedroFabricio Simões PerinSonia Tsukasa NozawaCláudio Ernesto Albers MendesRodrigo de Souza BarrosoNydia Strachman BacalABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000300366&lng=en&tlng=enHemoglobinúria paroxística/diagnósticoCitometria de fluxo/métodosDesenvolvimento tecnológico
spellingShingle Rodolfo Patussi Correia
Laiz Cameirão Bento
Ana Carolina Apelle Bortolucci
Anderson Marega Alexandre
Andressa da Costa Vaz
Daniela Schimidell
Eduardo de Carvalho Pedro
Fabricio Simões Perin
Sonia Tsukasa Nozawa
Cláudio Ernesto Albers Mendes
Rodrigo de Souza Barroso
Nydia Strachman Bacal
Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
Einstein (São Paulo)
Hemoglobinúria paroxística/diagnóstico
Citometria de fluxo/métodos
Desenvolvimento tecnológico
title Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
title_full Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
title_fullStr Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
title_full_unstemmed Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
title_short Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
title_sort technical advances in flow cytometry based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
topic Hemoglobinúria paroxística/diagnóstico
Citometria de fluxo/métodos
Desenvolvimento tecnológico
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000300366&lng=en&tlng=en
work_keys_str_mv AT rodolfopatussicorreia technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT laizcameiraobento technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT anacarolinaapellebortolucci technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT andersonmaregaalexandre technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT andressadacostavaz technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT danielaschimidell technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT eduardodecarvalhopedro technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT fabriciosimoesperin technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT soniatsukasanozawa technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT claudioernestoalbersmendes technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT rodrigodesouzabarroso technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria
AT nydiastrachmanbacal technicaladvancesinflowcytometrybaseddiagnosisandmonitoringofparoxysmalnocturnalhemoglobinuria