Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti

Multiphase electric motors have smaller torque pulsations and are more reliable that their three-phase alternatives. However, standard electricity grids around the world are three-phase, so power inverter is needed to drive multiphase motors. Inverter is used not only to power the motor, but also to...

Full description

Bibliographic Details
Main Author: Tadas Lipinskis
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2014-04-01
Series:Mokslas: Lietuvos Ateitis
Subjects:
Online Access:http://journals.vgtu.lt/index.php/MLA/article/view/3528
_version_ 1818999577130303488
author Tadas Lipinskis
author_facet Tadas Lipinskis
author_sort Tadas Lipinskis
collection DOAJ
description Multiphase electric motors have smaller torque pulsations and are more reliable that their three-phase alternatives. However, standard electricity grids around the world are three-phase, so power inverter is needed to drive multiphase motors. Inverter is used not only to power the motor, but also to control the am­plitude and frequency of the produced voltage, thus controlling motor speed and torque. Multiphase systems with odd number of phases have been widely investigated; therefore, this paper focuses on a six-phase inverter with a single neutral symmetrical load. A novel asymmetrical space vector modulation scheme is proposed and evaluated using simulations in Matlab/Simulink. Simulation results are compared to other modulation schemes. The proposed method is suitable for generating near-sinusoidal output voltages; however, it might not be suited for driving motors with sinusoidally distributed stator windings. Santrauka Daugiafaziai elektros varikliai turi mažesnes sukimo momento pulsacijas ir didesnį patikimumą, lyginant su trifaziais varikliais. Pasaulyje paplitę trijų fazių elektros tinklai, todėl daugiafaziams varikliams maitinti reikalingi dažnio keitikliai, keičiantys standartinę vienfazę arba trifazę tinklo įtampą į daugiafazę. Dažnio keitiklis keičia ir išėjimo įtampos amplitudę, ir dažnį. Tai sudaro galimybių tiksliai valdyti variklio greitį. Literatūroje plačiai išnagrinėti daugiafazės įtampos formavimo metodai, esant nelyginiam fazių skaičiui. Darbe siūlomas naujas erdvinių vektorių asimetrinis įtampos formavimo algoritmas šešių fazių dažnio keitikliui, apkrautam simetrine apkrova su viena neutrale. Algoritmas tiriamas Matlab / Simulink programa, rezultatai palyginami su gautais, taikant kitus šešiafazės įtampos formavimo metodus. Reikšminiai žodžiai: šešiafazis variklis, šešiafazis dažnio keitiklis, erdvinių vektorių įtampos formavimo metodas.
first_indexed 2024-12-20T22:19:38Z
format Article
id doaj.art-c81fb5ac787f4e3cb26f8e08da9285e2
institution Directory Open Access Journal
issn 2029-2341
2029-2252
language English
last_indexed 2024-12-20T22:19:38Z
publishDate 2014-04-01
publisher Vilnius Gediminas Technical University
record_format Article
series Mokslas: Lietuvos Ateitis
spelling doaj.art-c81fb5ac787f4e3cb26f8e08da9285e22022-12-21T19:24:58ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522014-04-016210.3846/mla.2014.23Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuotiTadas Lipinskis0Vilniaus Gedimino technikos universitetasMultiphase electric motors have smaller torque pulsations and are more reliable that their three-phase alternatives. However, standard electricity grids around the world are three-phase, so power inverter is needed to drive multiphase motors. Inverter is used not only to power the motor, but also to control the am­plitude and frequency of the produced voltage, thus controlling motor speed and torque. Multiphase systems with odd number of phases have been widely investigated; therefore, this paper focuses on a six-phase inverter with a single neutral symmetrical load. A novel asymmetrical space vector modulation scheme is proposed and evaluated using simulations in Matlab/Simulink. Simulation results are compared to other modulation schemes. The proposed method is suitable for generating near-sinusoidal output voltages; however, it might not be suited for driving motors with sinusoidally distributed stator windings. Santrauka Daugiafaziai elektros varikliai turi mažesnes sukimo momento pulsacijas ir didesnį patikimumą, lyginant su trifaziais varikliais. Pasaulyje paplitę trijų fazių elektros tinklai, todėl daugiafaziams varikliams maitinti reikalingi dažnio keitikliai, keičiantys standartinę vienfazę arba trifazę tinklo įtampą į daugiafazę. Dažnio keitiklis keičia ir išėjimo įtampos amplitudę, ir dažnį. Tai sudaro galimybių tiksliai valdyti variklio greitį. Literatūroje plačiai išnagrinėti daugiafazės įtampos formavimo metodai, esant nelyginiam fazių skaičiui. Darbe siūlomas naujas erdvinių vektorių asimetrinis įtampos formavimo algoritmas šešių fazių dažnio keitikliui, apkrautam simetrine apkrova su viena neutrale. Algoritmas tiriamas Matlab / Simulink programa, rezultatai palyginami su gautais, taikant kitus šešiafazės įtampos formavimo metodus. Reikšminiai žodžiai: šešiafazis variklis, šešiafazis dažnio keitiklis, erdvinių vektorių įtampos formavimo metodas.http://journals.vgtu.lt/index.php/MLA/article/view/3528large and medium space vectorssix phase invertersix-phase motorasymmetrical SVPWM
spellingShingle Tadas Lipinskis
Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
Mokslas: Lietuvos Ateitis
large and medium space vectors
six phase inverter
six-phase motor
asymmetrical SVPWM
title Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
title_full Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
title_fullStr Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
title_full_unstemmed Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
title_short Asymmetrical six-phase space vector pwm scheme / Asimetrinis erdvinio vektoriaus moduliavimo metodas šešių fazių įtampai formuoti
title_sort asymmetrical six phase space vector pwm scheme asimetrinis erdvinio vektoriaus moduliavimo metodas sesiu faziu itampai formuoti
topic large and medium space vectors
six phase inverter
six-phase motor
asymmetrical SVPWM
url http://journals.vgtu.lt/index.php/MLA/article/view/3528
work_keys_str_mv AT tadaslipinskis asymmetricalsixphasespacevectorpwmschemeasimetriniserdviniovektoriausmoduliavimometodassesiufaziuitampaiformuoti