Development and Validation of a Portable Human Body Joint Power Test System

A portable human body joint power test system was developed using inertial sensor technology and wireless Bluetooth acquisition technology. A detailed description of the internal structure of the system and the data processing method involved is provided. The test system uses the cubic spline interp...

Full description

Bibliographic Details
Main Authors: Lin Li, Zhongqiu Ji, Ye Xia, Rui Gong
Format: Article
Language:English
Published: Hindawi - SAGE Publishing 2015-08-01
Series:International Journal of Distributed Sensor Networks
Online Access:https://doi.org/10.1155/2015/341072
_version_ 1797717291228463104
author Lin Li
Zhongqiu Ji
Ye Xia
Rui Gong
author_facet Lin Li
Zhongqiu Ji
Ye Xia
Rui Gong
author_sort Lin Li
collection DOAJ
description A portable human body joint power test system was developed using inertial sensor technology and wireless Bluetooth acquisition technology. A detailed description of the internal structure of the system and the data processing method involved is provided. The test system uses the cubic spline interpolation method, which is very convenient for obtaining the maximum peak points of muscle isotonic contraction joint power curves under different loads. Moreover, the system is portable and can be deployed in the classroom and the playground for education and testing. The test system is very useful in many respects, such as athlete selection and daily strength training. We established a model of our subject using a balanced proportion scaling method in the inverse dynamics software AnyBody modeling system. The muscle model uses the Hill muscle model. The data import interface program was written in the parameterized model definition language AnyScript to import data. The raw data was smoothed with a Butterworth low-pass filter. Dumbbell curl simulation was conducted in AnyBody. The results of the simulation and those of the real test system were tested using the paired samples t -test method; the value of Sig was determined to be greater than 0.05, indicating no significant difference and that the data of the test system are valid.
first_indexed 2024-03-12T08:34:12Z
format Article
id doaj.art-c82694e5d0054fd59c752c4432cc0ee4
institution Directory Open Access Journal
issn 1550-1477
language English
last_indexed 2024-03-12T08:34:12Z
publishDate 2015-08-01
publisher Hindawi - SAGE Publishing
record_format Article
series International Journal of Distributed Sensor Networks
spelling doaj.art-c82694e5d0054fd59c752c4432cc0ee42023-09-02T17:23:33ZengHindawi - SAGE PublishingInternational Journal of Distributed Sensor Networks1550-14772015-08-011110.1155/2015/341072341072Development and Validation of a Portable Human Body Joint Power Test SystemLin Li0Zhongqiu Ji1Ye Xia2Rui Gong3 College of PE and Sports, Beijing Normal University, Beijing 100875, China College of PE and Sports, Beijing Normal University, Beijing 100875, China College of Information Science and Technology, Beijing Normal University, Beijing 100875, China College of PE and Sports, Beijing Normal University, Beijing 100875, ChinaA portable human body joint power test system was developed using inertial sensor technology and wireless Bluetooth acquisition technology. A detailed description of the internal structure of the system and the data processing method involved is provided. The test system uses the cubic spline interpolation method, which is very convenient for obtaining the maximum peak points of muscle isotonic contraction joint power curves under different loads. Moreover, the system is portable and can be deployed in the classroom and the playground for education and testing. The test system is very useful in many respects, such as athlete selection and daily strength training. We established a model of our subject using a balanced proportion scaling method in the inverse dynamics software AnyBody modeling system. The muscle model uses the Hill muscle model. The data import interface program was written in the parameterized model definition language AnyScript to import data. The raw data was smoothed with a Butterworth low-pass filter. Dumbbell curl simulation was conducted in AnyBody. The results of the simulation and those of the real test system were tested using the paired samples t -test method; the value of Sig was determined to be greater than 0.05, indicating no significant difference and that the data of the test system are valid.https://doi.org/10.1155/2015/341072
spellingShingle Lin Li
Zhongqiu Ji
Ye Xia
Rui Gong
Development and Validation of a Portable Human Body Joint Power Test System
International Journal of Distributed Sensor Networks
title Development and Validation of a Portable Human Body Joint Power Test System
title_full Development and Validation of a Portable Human Body Joint Power Test System
title_fullStr Development and Validation of a Portable Human Body Joint Power Test System
title_full_unstemmed Development and Validation of a Portable Human Body Joint Power Test System
title_short Development and Validation of a Portable Human Body Joint Power Test System
title_sort development and validation of a portable human body joint power test system
url https://doi.org/10.1155/2015/341072
work_keys_str_mv AT linli developmentandvalidationofaportablehumanbodyjointpowertestsystem
AT zhongqiuji developmentandvalidationofaportablehumanbodyjointpowertestsystem
AT yexia developmentandvalidationofaportablehumanbodyjointpowertestsystem
AT ruigong developmentandvalidationofaportablehumanbodyjointpowertestsystem