Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)

Introduction: Osseointegration as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows protocol choice on a patient to patient basis and p...

Full description

Bibliographic Details
Main Authors: Vidya Hiranmayi Kastala, Mulpuri Venkata Ramoji Rao
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Indian Journal of Dental Research
Subjects:
Online Access:http://www.ijdr.in/article.asp?issn=0970-9290;year=2019;volume=30;issue=5;spage=678;epage=686;aulast=Kastala
_version_ 1818574898602180608
author Vidya Hiranmayi Kastala
Mulpuri Venkata Ramoji Rao
author_facet Vidya Hiranmayi Kastala
Mulpuri Venkata Ramoji Rao
author_sort Vidya Hiranmayi Kastala
collection DOAJ
description Introduction: Osseointegration as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows protocol choice on a patient to patient basis and provides enhanced case documentation. The RFA technique provides with clinically relevant information about the state of the implant–bone interface at any stage after implant placement. Aim: Evaluation of primary and secondary stability between implants of two different systems by resonance frequency analysis device. Methodology: This study was conducted among 17 patients divided into two groups. Group 1 (n = 10) receiving 20 MIS seven implants and Group 2 (n = 7) received 20 Alphadent active implants. The primary implant stability was measured at the time of implant placement and secondary stability is measured at 3–4 months interval using RFA device OSSTELL ISQ. Statistical analysis was performed using paired t test for intra group and independent sample test for intergroup comparisons. Results: No statistically significant differences in primary and secondary stabilities were found between the implant systems at either time intervals (P > 0.05). A positive correlation was noticed between mesiodistal stability and implant diameter in MIS seven group (P < 0.05). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant diameter in Alphadent group (P = 0.03). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant length in Alphadent group (P = 0.03). Conclusion: From the present data, it can be concluded that within the limitations of study, implant systems used and their design features showed no significant correlation to implant stability between the groups. More studies are required to assess the effect of implant designs and surface conditions on implant stability on a long-term basis.
first_indexed 2024-12-15T00:32:28Z
format Article
id doaj.art-c8ec863f0085409cb81ae426f637f5cf
institution Directory Open Access Journal
issn 0970-9290
1998-3603
language English
last_indexed 2024-12-15T00:32:28Z
publishDate 2019-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Dental Research
spelling doaj.art-c8ec863f0085409cb81ae426f637f5cf2022-12-21T22:41:56ZengWolters Kluwer Medknow PublicationsIndian Journal of Dental Research0970-92901998-36032019-01-0130567868610.4103/ijdr.IJDR_446_17Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)Vidya Hiranmayi KastalaMulpuri Venkata Ramoji RaoIntroduction: Osseointegration as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows protocol choice on a patient to patient basis and provides enhanced case documentation. The RFA technique provides with clinically relevant information about the state of the implant–bone interface at any stage after implant placement. Aim: Evaluation of primary and secondary stability between implants of two different systems by resonance frequency analysis device. Methodology: This study was conducted among 17 patients divided into two groups. Group 1 (n = 10) receiving 20 MIS seven implants and Group 2 (n = 7) received 20 Alphadent active implants. The primary implant stability was measured at the time of implant placement and secondary stability is measured at 3–4 months interval using RFA device OSSTELL ISQ. Statistical analysis was performed using paired t test for intra group and independent sample test for intergroup comparisons. Results: No statistically significant differences in primary and secondary stabilities were found between the implant systems at either time intervals (P > 0.05). A positive correlation was noticed between mesiodistal stability and implant diameter in MIS seven group (P < 0.05). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant diameter in Alphadent group (P = 0.03). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant length in Alphadent group (P = 0.03). Conclusion: From the present data, it can be concluded that within the limitations of study, implant systems used and their design features showed no significant correlation to implant stability between the groups. More studies are required to assess the effect of implant designs and surface conditions on implant stability on a long-term basis.http://www.ijdr.in/article.asp?issn=0970-9290;year=2019;volume=30;issue=5;spage=678;epage=686;aulast=Kastalaendosseous implantsosseointegrationprimary stabilityresonance frequency analysissecondary stability
spellingShingle Vidya Hiranmayi Kastala
Mulpuri Venkata Ramoji Rao
Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
Indian Journal of Dental Research
endosseous implants
osseointegration
primary stability
resonance frequency analysis
secondary stability
title Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
title_full Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
title_fullStr Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
title_full_unstemmed Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
title_short Comparative evaluation of implant stability in two different implant systems at baseline and 3–4 months intervals using RFA device (OSSTELL ISQ)
title_sort comparative evaluation of implant stability in two different implant systems at baseline and 3 4 months intervals using rfa device osstell isq
topic endosseous implants
osseointegration
primary stability
resonance frequency analysis
secondary stability
url http://www.ijdr.in/article.asp?issn=0970-9290;year=2019;volume=30;issue=5;spage=678;epage=686;aulast=Kastala
work_keys_str_mv AT vidyahiranmayikastala comparativeevaluationofimplantstabilityintwodifferentimplantsystemsatbaselineand34monthsintervalsusingrfadeviceosstellisq
AT mulpurivenkataramojirao comparativeevaluationofimplantstabilityintwodifferentimplantsystemsatbaselineand34monthsintervalsusingrfadeviceosstellisq