Summary: | A typical submersible well pump was investigated in this article. The whole flow field of submersible well pump was numerically simulated by computational fluid dynamics software. The influence of clearance of wear-rings on the external characteristic and internal flow field was analyzed through comparing the calculation results with experimental results. The result of the numerical simulation shows that changing clearance of front wear-ring has a greater impact on pump performances than changing clearance of back wear-ring, and the head and efficiency of pump decrease with the increase in the size of clearance. Especially when the size of clearance is larger than 0.5 mm, decreasing becomes more obvious. When the front and back wear-ring size of the clearance comes to 1.0 mm, the efficiency decreases from the highest point of 75.31% to 65.44% at rated flow, and the head of pump decreases about 3.5 m. When the size of clearance is 0.2 mm, reverse-flow will appear in the front shroud cavity of the impeller, and leakage from back wear-ring through the balance hole into the impeller, which has a little influence on the flow field of the impeller inlet.
|