Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry

<p>Hydroxyl and hydroperoxy radicals are key species for the understanding of atmospheric oxidation processes. Their measurement is challenging due to their high reactivity; therefore, very sensitive detection methods are needed. Within this study, the measurement of hydroperoxy radicals (<...

Full description

Bibliographic Details
Main Authors: S. R. Albrecht, A. Novelli, A. Hofzumahaus, S. Kang, Y. Baker, T. Mentel, A. Wahner, H. Fuchs
Format: Article
Language:English
Published: Copernicus Publications 2019-02-01
Series:Atmospheric Measurement Techniques
Online Access:https://www.atmos-meas-tech.net/12/891/2019/amt-12-891-2019.pdf
_version_ 1818855553897594880
author S. R. Albrecht
A. Novelli
A. Hofzumahaus
S. Kang
Y. Baker
T. Mentel
A. Wahner
H. Fuchs
author_facet S. R. Albrecht
A. Novelli
A. Hofzumahaus
S. Kang
Y. Baker
T. Mentel
A. Wahner
H. Fuchs
author_sort S. R. Albrecht
collection DOAJ
description <p>Hydroxyl and hydroperoxy radicals are key species for the understanding of atmospheric oxidation processes. Their measurement is challenging due to their high reactivity; therefore, very sensitive detection methods are needed. Within this study, the measurement of hydroperoxy radicals (<span class="inline-formula">HO<sub>2</sub></span>) using chemical ionisation combined with a high-resolution time-of-flight mass spectrometer (Aerodyne Research Inc.) employing bromide as the primary ion is presented. The sensitivity reached is equal to <span class="inline-formula">0.005×10<sup>8</sup></span> <span class="inline-formula">HO<sub>2</sub></span>&thinsp;cm<span class="inline-formula"><sup>−3</sup></span> for 10<span class="inline-formula"><sup>6</sup></span>&thinsp;cps of bromide and 60&thinsp;s of integration time, which is below typical <span class="inline-formula">HO<sub>2</sub></span> concentrations found in the atmosphere. The detection sensitivity of the instrument is affected by the presence of water vapour. Therefore, a water-vapour-dependent calibration factor that decreases approximately by a factor of 2 if the water vapour mixing ratio increases from 0.1&thinsp;<span class="inline-formula">%</span> to 1.0&thinsp;<span class="inline-formula">%</span> needs to be applied. An instrumental background, most likely generated by the ion source that is equivalent to a <span class="inline-formula">HO<sub>2</sub></span> concentration of <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M13" display="inline" overflow="scroll" dspmath="mathml"><mrow><mo>(</mo><mn mathvariant="normal">1.5</mn><mo>±</mo><mn mathvariant="normal">0.2</mn><mo>)</mo><mo>×</mo><msup><mn mathvariant="normal">10</mn><mn mathvariant="normal">8</mn></msup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="79pt" height="15pt" class="svg-formula" dspmath="mathimg" md5hash="d17ed23b129252ba5aebbaaaa3c31c27"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-12-891-2019-ie00001.svg" width="79pt" height="15pt" src="amt-12-891-2019-ie00001.png"/></svg:svg></span></span>&thinsp;<span class="inline-formula">molecules cm<sup>−3</sup></span>, is subtracted to derive atmospheric <span class="inline-formula">HO<sub>2</sub></span> concentrations. This background can be determined by overflowing the inlet with zero air. Several experiments were performed in the atmospheric simulation chamber SAPHIR at the Forschungszentrum Jülich to test the instrument performance in comparison to the well-established laser-induced fluorescence (LIF) technique for measurements of <span class="inline-formula">HO<sub>2</sub></span>. A highly linear correlation coefficient of <span class="inline-formula"><i>R</i><sup>2</sup>=0.87</span> is achieved. The slope of the linear regression of 1.07 demonstrates the good absolute agreement of both measurements. Chemical conditions during experiments allowed for testing the instrument's behaviour in the presence of atmospheric concentrations of <span class="inline-formula">H<sub>2</sub>O</span>, <span class="inline-formula">NO<sub><i>x</i></sub></span>, and <span class="inline-formula">O<sub>3</sub></span>. No significant interferences from these species were observed. All of these facts demonstrate a reliable measurement of <span class="inline-formula">HO<sub>2</sub></span> by the chemical ionisation mass spectrometer presented.</p>
first_indexed 2024-12-19T08:10:26Z
format Article
id doaj.art-c943dcc7cce84eabb03f936801aca42a
institution Directory Open Access Journal
issn 1867-1381
1867-8548
language English
last_indexed 2024-12-19T08:10:26Z
publishDate 2019-02-01
publisher Copernicus Publications
record_format Article
series Atmospheric Measurement Techniques
spelling doaj.art-c943dcc7cce84eabb03f936801aca42a2022-12-21T20:29:39ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482019-02-011289190210.5194/amt-12-891-2019Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometryS. R. Albrecht0A. Novelli1A. Hofzumahaus2S. Kang3Y. Baker4T. Mentel5A. Wahner6H. Fuchs7Institute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, GermanyInstitute of Energy and Climate Research – Troposphere (IEK-8), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany<p>Hydroxyl and hydroperoxy radicals are key species for the understanding of atmospheric oxidation processes. Their measurement is challenging due to their high reactivity; therefore, very sensitive detection methods are needed. Within this study, the measurement of hydroperoxy radicals (<span class="inline-formula">HO<sub>2</sub></span>) using chemical ionisation combined with a high-resolution time-of-flight mass spectrometer (Aerodyne Research Inc.) employing bromide as the primary ion is presented. The sensitivity reached is equal to <span class="inline-formula">0.005×10<sup>8</sup></span> <span class="inline-formula">HO<sub>2</sub></span>&thinsp;cm<span class="inline-formula"><sup>−3</sup></span> for 10<span class="inline-formula"><sup>6</sup></span>&thinsp;cps of bromide and 60&thinsp;s of integration time, which is below typical <span class="inline-formula">HO<sub>2</sub></span> concentrations found in the atmosphere. The detection sensitivity of the instrument is affected by the presence of water vapour. Therefore, a water-vapour-dependent calibration factor that decreases approximately by a factor of 2 if the water vapour mixing ratio increases from 0.1&thinsp;<span class="inline-formula">%</span> to 1.0&thinsp;<span class="inline-formula">%</span> needs to be applied. An instrumental background, most likely generated by the ion source that is equivalent to a <span class="inline-formula">HO<sub>2</sub></span> concentration of <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M13" display="inline" overflow="scroll" dspmath="mathml"><mrow><mo>(</mo><mn mathvariant="normal">1.5</mn><mo>±</mo><mn mathvariant="normal">0.2</mn><mo>)</mo><mo>×</mo><msup><mn mathvariant="normal">10</mn><mn mathvariant="normal">8</mn></msup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="79pt" height="15pt" class="svg-formula" dspmath="mathimg" md5hash="d17ed23b129252ba5aebbaaaa3c31c27"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-12-891-2019-ie00001.svg" width="79pt" height="15pt" src="amt-12-891-2019-ie00001.png"/></svg:svg></span></span>&thinsp;<span class="inline-formula">molecules cm<sup>−3</sup></span>, is subtracted to derive atmospheric <span class="inline-formula">HO<sub>2</sub></span> concentrations. This background can be determined by overflowing the inlet with zero air. Several experiments were performed in the atmospheric simulation chamber SAPHIR at the Forschungszentrum Jülich to test the instrument performance in comparison to the well-established laser-induced fluorescence (LIF) technique for measurements of <span class="inline-formula">HO<sub>2</sub></span>. A highly linear correlation coefficient of <span class="inline-formula"><i>R</i><sup>2</sup>=0.87</span> is achieved. The slope of the linear regression of 1.07 demonstrates the good absolute agreement of both measurements. Chemical conditions during experiments allowed for testing the instrument's behaviour in the presence of atmospheric concentrations of <span class="inline-formula">H<sub>2</sub>O</span>, <span class="inline-formula">NO<sub><i>x</i></sub></span>, and <span class="inline-formula">O<sub>3</sub></span>. No significant interferences from these species were observed. All of these facts demonstrate a reliable measurement of <span class="inline-formula">HO<sub>2</sub></span> by the chemical ionisation mass spectrometer presented.</p>https://www.atmos-meas-tech.net/12/891/2019/amt-12-891-2019.pdf
spellingShingle S. R. Albrecht
A. Novelli
A. Hofzumahaus
S. Kang
Y. Baker
T. Mentel
A. Wahner
H. Fuchs
Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
Atmospheric Measurement Techniques
title Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
title_full Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
title_fullStr Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
title_full_unstemmed Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
title_short Measurements of hydroperoxy radicals (HO<sub>2</sub>) at atmospheric concentrations using bromide chemical ionisation mass spectrometry
title_sort measurements of hydroperoxy radicals ho sub 2 sub at atmospheric concentrations using bromide chemical ionisation mass spectrometry
url https://www.atmos-meas-tech.net/12/891/2019/amt-12-891-2019.pdf
work_keys_str_mv AT sralbrecht measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT anovelli measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT ahofzumahaus measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT skang measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT ybaker measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT tmentel measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT awahner measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry
AT hfuchs measurementsofhydroperoxyradicalshosub2subatatmosphericconcentrationsusingbromidechemicalionisationmassspectrometry