The novel solution of ball valve with replaceable orifice. Numerical and field tests
The article presents the results of numerical calculations and experimental results of a flow through the orifice. Such a measuring device was built-into the ball valve that gave unique possibility of the orifice exchange without the pipeline disassemble. The advantages of using the prototypical sol...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
De Gruyter
2019-08-01
|
Series: | Open Engineering |
Subjects: | |
Online Access: | https://doi.org/10.1515/eng-2019-0034 |
_version_ | 1818597462867181568 |
---|---|
author | Romanik Grzegorz Rogula Janusz |
author_facet | Romanik Grzegorz Rogula Janusz |
author_sort | Romanik Grzegorz |
collection | DOAJ |
description | The article presents the results of numerical calculations and experimental results of a flow through the orifice. Such a measuring device was built-into the ball valve that gave unique possibility of the orifice exchange without the pipeline disassemble. The advantages of using the prototypical solution has been described. This patented solution has been tested extensively for the durability and tightness. The article contains comparison between flow character in the case of single-hole orifice and a multi-nozzle one. The prototypical measuring device has been produced and assembled in compressed air system in the Power Plant Opole, that gave experimental verification of theoretical approach. |
first_indexed | 2024-12-16T11:48:12Z |
format | Article |
id | doaj.art-c9a07db05dcc4fbcbadd3723f5afaf09 |
institution | Directory Open Access Journal |
issn | 2391-5439 |
language | English |
last_indexed | 2024-12-16T11:48:12Z |
publishDate | 2019-08-01 |
publisher | De Gruyter |
record_format | Article |
series | Open Engineering |
spelling | doaj.art-c9a07db05dcc4fbcbadd3723f5afaf092022-12-21T22:32:47ZengDe GruyterOpen Engineering2391-54392019-08-019125325910.1515/eng-2019-0034eng-2019-0034The novel solution of ball valve with replaceable orifice. Numerical and field testsRomanik Grzegorz0Rogula Janusz1Wroclaw University of Science and Technology, Faculty of Mechanical and Power Engineering, Department of Design Fundamentals and Fluid–Flow Machinery, Wroclaw, PolandWroclaw University of Science and Technology, Faculty of Mechanical and Power Engineering, Department of Design Fundamentals and Fluid–Flow Machinery, Wroclaw, PolandThe article presents the results of numerical calculations and experimental results of a flow through the orifice. Such a measuring device was built-into the ball valve that gave unique possibility of the orifice exchange without the pipeline disassemble. The advantages of using the prototypical solution has been described. This patented solution has been tested extensively for the durability and tightness. The article contains comparison between flow character in the case of single-hole orifice and a multi-nozzle one. The prototypical measuring device has been produced and assembled in compressed air system in the Power Plant Opole, that gave experimental verification of theoretical approach.https://doi.org/10.1515/eng-2019-0034flow metersimulationgas flowdesign |
spellingShingle | Romanik Grzegorz Rogula Janusz The novel solution of ball valve with replaceable orifice. Numerical and field tests Open Engineering flow meter simulation gas flow design |
title | The novel solution of ball valve with replaceable orifice. Numerical and field tests |
title_full | The novel solution of ball valve with replaceable orifice. Numerical and field tests |
title_fullStr | The novel solution of ball valve with replaceable orifice. Numerical and field tests |
title_full_unstemmed | The novel solution of ball valve with replaceable orifice. Numerical and field tests |
title_short | The novel solution of ball valve with replaceable orifice. Numerical and field tests |
title_sort | novel solution of ball valve with replaceable orifice numerical and field tests |
topic | flow meter simulation gas flow design |
url | https://doi.org/10.1515/eng-2019-0034 |
work_keys_str_mv | AT romanikgrzegorz thenovelsolutionofballvalvewithreplaceableorificenumericalandfieldtests AT rogulajanusz thenovelsolutionofballvalvewithreplaceableorificenumericalandfieldtests AT romanikgrzegorz novelsolutionofballvalvewithreplaceableorificenumericalandfieldtests AT rogulajanusz novelsolutionofballvalvewithreplaceableorificenumericalandfieldtests |