In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements

The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement o...

Full description

Bibliographic Details
Main Authors: Hoffman N.M., Herrmann H.W., Kim Y.H., Hsu H.H., Horsfield C.J., Rubery M.S., Wilson D.C., W. Stoeffl W., Young C.S., Mack J.M., Miller E.K., Grafil E., Evans S.C., Sedillo T.J., Glebov V.Yu., Duffy T.
Format: Article
Language:English
Published: EDP Sciences 2013-11-01
Series:EPJ Web of Conferences
Online Access:http://dx.doi.org/10.1051/epjconf/20135913019
_version_ 1831659676146597888
author Hoffman N.M.
Herrmann H.W.
Kim Y.H.
Hsu H.H.
Horsfield C.J.
Rubery M.S.
Wilson D.C.
W. Stoeffl W.
Young C.S.
Mack J.M.
Miller E.K.
Grafil E.
Evans S.C.
Sedillo T.J.
Glebov V.Yu.
Duffy T.
author_facet Hoffman N.M.
Herrmann H.W.
Kim Y.H.
Hsu H.H.
Horsfield C.J.
Rubery M.S.
Wilson D.C.
W. Stoeffl W.
Young C.S.
Mack J.M.
Miller E.K.
Grafil E.
Evans S.C.
Sedillo T.J.
Glebov V.Yu.
Duffy T.
author_sort Hoffman N.M.
collection DOAJ
description The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement of ablator areal density ⟨ρR⟩abl in plastic-ablator DT-filled capsules at OMEGA [2], by allowing ⟨ρR⟩abl to be inferred as a function of ratios of signals rather than from absolute measurements of signal magnitudes. Systematic uncertainties in signal measurements and detector responses therefore cancel, permitting more accurate measurements of ⟨ρR⟩abl.
first_indexed 2024-12-19T18:02:50Z
format Article
id doaj.art-c9a6cc9b4c8e4a1db753e11c76d66ab1
institution Directory Open Access Journal
issn 2100-014X
language English
last_indexed 2024-12-19T18:02:50Z
publishDate 2013-11-01
publisher EDP Sciences
record_format Article
series EPJ Web of Conferences
spelling doaj.art-c9a6cc9b4c8e4a1db753e11c76d66ab12022-12-21T20:11:33ZengEDP SciencesEPJ Web of Conferences2100-014X2013-11-01591301910.1051/epjconf/20135913019In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurementsHoffman N.M.Herrmann H.W.Kim Y.H.Hsu H.H.Horsfield C.J.Rubery M.S.Wilson D.C.W. Stoeffl W.Young C.S.Mack J.M.Miller E.K.Grafil E.Evans S.C.Sedillo T.J.Glebov V.Yu.Duffy T.The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement of ablator areal density ⟨ρR⟩abl in plastic-ablator DT-filled capsules at OMEGA [2], by allowing ⟨ρR⟩abl to be inferred as a function of ratios of signals rather than from absolute measurements of signal magnitudes. Systematic uncertainties in signal measurements and detector responses therefore cancel, permitting more accurate measurements of ⟨ρR⟩abl.http://dx.doi.org/10.1051/epjconf/20135913019
spellingShingle Hoffman N.M.
Herrmann H.W.
Kim Y.H.
Hsu H.H.
Horsfield C.J.
Rubery M.S.
Wilson D.C.
W. Stoeffl W.
Young C.S.
Mack J.M.
Miller E.K.
Grafil E.
Evans S.C.
Sedillo T.J.
Glebov V.Yu.
Duffy T.
In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
EPJ Web of Conferences
title In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
title_full In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
title_fullStr In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
title_full_unstemmed In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
title_short In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
title_sort in situ calibration of the gamma reaction history instrument using reference samples pucks for areal density measurements
url http://dx.doi.org/10.1051/epjconf/20135913019
work_keys_str_mv AT hoffmannm insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT herrmannhw insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT kimyh insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT hsuhh insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT horsfieldcj insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT ruberyms insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT wilsondc insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT wstoefflw insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT youngcs insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT mackjm insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT millerek insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT grafile insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT evanssc insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT sedillotj insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT glebovvyu insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements
AT duffyt insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements