In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements
The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement o...
Main Authors: | , , , , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2013-11-01
|
Series: | EPJ Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/epjconf/20135913019 |
_version_ | 1831659676146597888 |
---|---|
author | Hoffman N.M. Herrmann H.W. Kim Y.H. Hsu H.H. Horsfield C.J. Rubery M.S. Wilson D.C. W. Stoeffl W. Young C.S. Mack J.M. Miller E.K. Grafil E. Evans S.C. Sedillo T.J. Glebov V.Yu. Duffy T. |
author_facet | Hoffman N.M. Herrmann H.W. Kim Y.H. Hsu H.H. Horsfield C.J. Rubery M.S. Wilson D.C. W. Stoeffl W. Young C.S. Mack J.M. Miller E.K. Grafil E. Evans S.C. Sedillo T.J. Glebov V.Yu. Duffy T. |
author_sort | Hoffman N.M. |
collection | DOAJ |
description | The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement of ablator areal density ⟨ρR⟩abl in plastic-ablator DT-filled capsules at OMEGA [2], by allowing ⟨ρR⟩abl to be inferred as a function of ratios of signals rather than from absolute measurements of signal magnitudes. Systematic uncertainties in signal measurements and detector responses therefore cancel, permitting more accurate measurements of ⟨ρR⟩abl. |
first_indexed | 2024-12-19T18:02:50Z |
format | Article |
id | doaj.art-c9a6cc9b4c8e4a1db753e11c76d66ab1 |
institution | Directory Open Access Journal |
issn | 2100-014X |
language | English |
last_indexed | 2024-12-19T18:02:50Z |
publishDate | 2013-11-01 |
publisher | EDP Sciences |
record_format | Article |
series | EPJ Web of Conferences |
spelling | doaj.art-c9a6cc9b4c8e4a1db753e11c76d66ab12022-12-21T20:11:33ZengEDP SciencesEPJ Web of Conferences2100-014X2013-11-01591301910.1051/epjconf/20135913019In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurementsHoffman N.M.Herrmann H.W.Kim Y.H.Hsu H.H.Horsfield C.J.Rubery M.S.Wilson D.C.W. Stoeffl W.Young C.S.Mack J.M.Miller E.K.Grafil E.Evans S.C.Sedillo T.J.Glebov V.Yu.Duffy T.The introduction of a sample of carbon, for example a disk or “puck”, near an imploding DT-filled capsule creates a source of 12C gamma rays that can serve as a reference for calibrating the response of the Gamma Reaction History (GRH) detector [1]. Such calibration is important in the measurement of ablator areal density ⟨ρR⟩abl in plastic-ablator DT-filled capsules at OMEGA [2], by allowing ⟨ρR⟩abl to be inferred as a function of ratios of signals rather than from absolute measurements of signal magnitudes. Systematic uncertainties in signal measurements and detector responses therefore cancel, permitting more accurate measurements of ⟨ρR⟩abl.http://dx.doi.org/10.1051/epjconf/20135913019 |
spellingShingle | Hoffman N.M. Herrmann H.W. Kim Y.H. Hsu H.H. Horsfield C.J. Rubery M.S. Wilson D.C. W. Stoeffl W. Young C.S. Mack J.M. Miller E.K. Grafil E. Evans S.C. Sedillo T.J. Glebov V.Yu. Duffy T. In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements EPJ Web of Conferences |
title | In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements |
title_full | In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements |
title_fullStr | In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements |
title_full_unstemmed | In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements |
title_short | In situ calibration of the Gamma Reaction History instrument using reference samples (“pucks”) for areal density measurements |
title_sort | in situ calibration of the gamma reaction history instrument using reference samples pucks for areal density measurements |
url | http://dx.doi.org/10.1051/epjconf/20135913019 |
work_keys_str_mv | AT hoffmannm insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT herrmannhw insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT kimyh insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT hsuhh insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT horsfieldcj insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT ruberyms insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT wilsondc insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT wstoefflw insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT youngcs insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT mackjm insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT millerek insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT grafile insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT evanssc insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT sedillotj insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT glebovvyu insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements AT duffyt insitucalibrationofthegammareactionhistoryinstrumentusingreferencesamplespucksforarealdensitymeasurements |