Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study

It is well known that nowadays a significant part of the total energy consumption is related to buildings, so research for improving building energy efficiency is very important. This paper presents our investigations about the dimensioning of horizontal overhangs in order to determine the minimum a...

Full description

Bibliographic Details
Main Authors: Danijela Nikolic, Slobodan Djordjevic, Jasmina Skerlic, Jasna Radulovic
Format: Article
Language:English
Published: MDPI AG 2020-09-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/17/4577
_version_ 1797554661991907328
author Danijela Nikolic
Slobodan Djordjevic
Jasmina Skerlic
Jasna Radulovic
author_facet Danijela Nikolic
Slobodan Djordjevic
Jasmina Skerlic
Jasna Radulovic
author_sort Danijela Nikolic
collection DOAJ
description It is well known that nowadays a significant part of the total energy consumption is related to buildings, so research for improving building energy efficiency is very important. This paper presents our investigations about the dimensioning of horizontal overhangs in order to determine the minimum annual consumption of building primary energy for heating, cooling and lighting. In this investigation, embodied energy for horizontal roof overhangs was taken into account. The annual simulation was carried out for a residential building located in the city of Belgrade (Serbia). Horizontal overhangs (roof and balcony) are positioned to provide shading of all exterior of the building. The building is simulated in the EnergyPlus software environment. The optimization of the overhang size was performed by using the Hooke Jeeves algorithm and plug-in GenOpt program. The objective function minimizes the annual consumption of primary energy for heating, cooling and lighting of the building and energy spent to build overhangs. The simulation results show that the building with optimally sized roof and balcony overhangs consumed 7.12% lessprimary energy for heating, cooling and lighting, compared to the house without overhangs. A 44.15% reduction in cooling energy consumption is also achieved.
first_indexed 2024-03-10T16:35:13Z
format Article
id doaj.art-c9ec52938fea4ed4a7f484b84f9061c5
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T16:35:13Z
publishDate 2020-09-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-c9ec52938fea4ed4a7f484b84f9061c52023-11-20T12:30:59ZengMDPI AGEnergies1996-10732020-09-011317457710.3390/en13174577Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case StudyDanijela Nikolic0Slobodan Djordjevic1Jasmina Skerlic2Jasna Radulovic3Faculty of Engineering, University of Kragujevac, 34000 Kragujevac, SerbiaFaculty of Engineering, University of Kragujevac, 34000 Kragujevac, SerbiaFaculty of Technical Sciences, University of Pristina temporarily settled in Kosovska Mitrovica, 38220 Kosovska Mitrovica, SerbiaFaculty of Engineering, University of Kragujevac, 34000 Kragujevac, SerbiaIt is well known that nowadays a significant part of the total energy consumption is related to buildings, so research for improving building energy efficiency is very important. This paper presents our investigations about the dimensioning of horizontal overhangs in order to determine the minimum annual consumption of building primary energy for heating, cooling and lighting. In this investigation, embodied energy for horizontal roof overhangs was taken into account. The annual simulation was carried out for a residential building located in the city of Belgrade (Serbia). Horizontal overhangs (roof and balcony) are positioned to provide shading of all exterior of the building. The building is simulated in the EnergyPlus software environment. The optimization of the overhang size was performed by using the Hooke Jeeves algorithm and plug-in GenOpt program. The objective function minimizes the annual consumption of primary energy for heating, cooling and lighting of the building and energy spent to build overhangs. The simulation results show that the building with optimally sized roof and balcony overhangs consumed 7.12% lessprimary energy for heating, cooling and lighting, compared to the house without overhangs. A 44.15% reduction in cooling energy consumption is also achieved.https://www.mdpi.com/1996-1073/13/17/4577buildingoverhangsenergy consumptionoptimizationGenOptEnergyPlus
spellingShingle Danijela Nikolic
Slobodan Djordjevic
Jasmina Skerlic
Jasna Radulovic
Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
Energies
building
overhangs
energy consumption
optimization
GenOpt
EnergyPlus
title Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
title_full Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
title_fullStr Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
title_full_unstemmed Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
title_short Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study
title_sort energy analyses of serbian buildings with horizontal overhangs a case study
topic building
overhangs
energy consumption
optimization
GenOpt
EnergyPlus
url https://www.mdpi.com/1996-1073/13/17/4577
work_keys_str_mv AT danijelanikolic energyanalysesofserbianbuildingswithhorizontaloverhangsacasestudy
AT slobodandjordjevic energyanalysesofserbianbuildingswithhorizontaloverhangsacasestudy
AT jasminaskerlic energyanalysesofserbianbuildingswithhorizontaloverhangsacasestudy
AT jasnaradulovic energyanalysesofserbianbuildingswithhorizontaloverhangsacasestudy