Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study

Aim: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON ® with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. Materials and Methods: A prospective observational study was co...

Full description

Bibliographic Details
Main Authors: Raj A Pedgaonkar, Naveen G Singh, Manasa Dhananjaya, P S Nagaraja, K S Nagesh, V Prabhakar
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2023-01-01
Series:Annals of Cardiac Anaesthesia
Subjects:
Online Access:http://www.annals.in/article.asp?issn=0971-9784;year=2023;volume=26;issue=4;spage=380;epage=385;aulast=Pedgaonkar
_version_ 1797300110920515584
author Raj A Pedgaonkar
Naveen G Singh
Manasa Dhananjaya
P S Nagaraja
K S Nagesh
V Prabhakar
author_facet Raj A Pedgaonkar
Naveen G Singh
Manasa Dhananjaya
P S Nagaraja
K S Nagesh
V Prabhakar
author_sort Raj A Pedgaonkar
collection DOAJ
description Aim: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON ® with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. Materials and Methods: A prospective observational study was conducted in 25 pediatric patients with age < 10 years who underwent elective cardiac surgery. Data Analysis: BlandAltman plot was constructed for interchangeability and Polar plot was constructed to know trending ability. Results: A total of 250 datasets were analyzed. Spearman's correlation coefficient for CO between ICON ® and TTE showed good positive correlation (r = 0.850, 95% confidence interval 0.81 to 0.881, P <.0001). Moderate positive correlation was observed between ICON ® and TTE for CI (r = 0.60, 95% confidence interval 0.515 to 0.674, P <.0001). Linear regression equations for CO and CI between ICON ® and TTE were: y = 0.5230 + 0.8078 X (R2 = 0.6597, P <.001) and y = 1.8350 + 0.5869 X (R2 = 0.3985, P <.001) [y- ICON ®; X - TTE], respectively. BlandAltman plot for CO between ICON ® and TTE showed a bias of 0.3012 with limits of agreement (LOA) being -0.69 to 1.3 and for CI bias was 0.6939 with LOA˗2.1 to 3.5. Polar plot analysis showed an angular bias of 8.1750, with radial LOA being −13.74° to 30.08° for CO and angular bias of 6.6931, with radial LOA being −15.69° to 29.07° for CI. Conclusion: ICON ® monitor-derived parameters are not interchangeable with the values derived from TTE. However, the ICON ® monitor demonstrated a good trending ability for both CO and CI.
first_indexed 2024-03-07T23:01:31Z
format Article
id doaj.art-ca4bf551b1864b64a8c079bf49171cbf
institution Directory Open Access Journal
issn 0971-9784
language English
last_indexed 2024-03-07T23:01:31Z
publishDate 2023-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Annals of Cardiac Anaesthesia
spelling doaj.art-ca4bf551b1864b64a8c079bf49171cbf2024-02-22T14:40:01ZengWolters Kluwer Medknow PublicationsAnnals of Cardiac Anaesthesia0971-97842023-01-0126438038510.4103/aca.aca_9_23Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational studyRaj A PedgaonkarNaveen G SinghManasa DhananjayaP S NagarajaK S NageshV PrabhakarAim: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON ® with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. Materials and Methods: A prospective observational study was conducted in 25 pediatric patients with age < 10 years who underwent elective cardiac surgery. Data Analysis: BlandAltman plot was constructed for interchangeability and Polar plot was constructed to know trending ability. Results: A total of 250 datasets were analyzed. Spearman's correlation coefficient for CO between ICON ® and TTE showed good positive correlation (r = 0.850, 95% confidence interval 0.81 to 0.881, P <.0001). Moderate positive correlation was observed between ICON ® and TTE for CI (r = 0.60, 95% confidence interval 0.515 to 0.674, P <.0001). Linear regression equations for CO and CI between ICON ® and TTE were: y = 0.5230 + 0.8078 X (R2 = 0.6597, P <.001) and y = 1.8350 + 0.5869 X (R2 = 0.3985, P <.001) [y- ICON ®; X - TTE], respectively. BlandAltman plot for CO between ICON ® and TTE showed a bias of 0.3012 with limits of agreement (LOA) being -0.69 to 1.3 and for CI bias was 0.6939 with LOA˗2.1 to 3.5. Polar plot analysis showed an angular bias of 8.1750, with radial LOA being −13.74° to 30.08° for CO and angular bias of 6.6931, with radial LOA being −15.69° to 29.07° for CI. Conclusion: ICON ® monitor-derived parameters are not interchangeable with the values derived from TTE. However, the ICON ® monitor demonstrated a good trending ability for both CO and CI.http://www.annals.in/article.asp?issn=0971-9784;year=2023;volume=26;issue=4;spage=380;epage=385;aulast=Pedgaonkarcardiac indexcardiac outputelectrical cardiometrytransthoracic echocardiography
spellingShingle Raj A Pedgaonkar
Naveen G Singh
Manasa Dhananjaya
P S Nagaraja
K S Nagesh
V Prabhakar
Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
Annals of Cardiac Anaesthesia
cardiac index
cardiac output
electrical cardiometry
transthoracic echocardiography
title Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
title_full Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
title_fullStr Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
title_full_unstemmed Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
title_short Comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - A prospective observational study
title_sort comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients a prospective observational study
topic cardiac index
cardiac output
electrical cardiometry
transthoracic echocardiography
url http://www.annals.in/article.asp?issn=0971-9784;year=2023;volume=26;issue=4;spage=380;epage=385;aulast=Pedgaonkar
work_keys_str_mv AT rajapedgaonkar comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT naveengsingh comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT manasadhananjaya comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT psnagaraja comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT ksnagesh comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT vprabhakar comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy