A high-resolution mass spectrometer to measure atmospheric ion composition
In this paper we present recent achievements on developing and testing a tool to detect the composition of ambient ions in the mass/charge range up to 2000 Th. The instrument is an Atmospheric Pressure Interface Time-of-Flight Mass Spectrometer (APi-TOF, Tofwerk AG). Its mass accuracy is better than...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Copernicus Publications
2010-08-01
|
Series: | Atmospheric Measurement Techniques |
Online Access: | http://www.atmos-meas-tech.net/3/1039/2010/amt-3-1039-2010.pdf |
_version_ | 1818230632710406144 |
---|---|
author | H. Junninen M. Ehn T. Petäjä L. Luosujärvi T. Kotiaho R. Kostiainen U. Rohner M. Gonin K. Fuhrer M. Kulmala D. R. Worsnop |
author_facet | H. Junninen M. Ehn T. Petäjä L. Luosujärvi T. Kotiaho R. Kostiainen U. Rohner M. Gonin K. Fuhrer M. Kulmala D. R. Worsnop |
author_sort | H. Junninen |
collection | DOAJ |
description | In this paper we present recent achievements on developing and testing a tool to detect the composition of ambient ions in the mass/charge range up to 2000 Th. The instrument is an Atmospheric Pressure Interface Time-of-Flight Mass Spectrometer (APi-TOF, Tofwerk AG). Its mass accuracy is better than 0.002%, and the mass resolving power is 3000 Th/Th. In the data analysis, a new efficient Matlab based set of programs (tofTools) were developed, tested and used. The APi-TOF was tested both in laboratory conditions and applied to outdoor air sampling in Helsinki at the SMEAR III station. Transmission efficiency calibrations showed a throughput of 0.1–0.5% in the range 100–1300 Th for positive ions, and linearity over 3 orders of magnitude in concentration was determined. In the laboratory tests the APi-TOF detected sulphuric acid-ammonia clusters in high concentration from a nebulised sample illustrating the potential of the instrument in revealing the role of sulphuric acid clusters in atmospheric new particle formation. The APi-TOF features a high enough accuracy, resolution and sensitivity for the determination of the composition of atmospheric small ions although the total concentration of those ions is typically only 400–2000 cm<sup>−3</sup>. The atmospheric ions were identified based on their exact masses, utilizing Kendrick analysis and correlograms as well as narrowing down the potential candidates based on their proton affinities as well isotopic patterns. In Helsinki during day-time the main negative ambient small ions were inorganic acids and their clusters. The positive ions were more complex, the main compounds were (poly)alkyl pyridines and – amines. The APi-TOF provides a near universal interface for atmospheric pressure sampling, and this key feature will be utilized in future laboratory and field studies. |
first_indexed | 2024-12-12T10:37:35Z |
format | Article |
id | doaj.art-ca61fa0758284a2d9f5c7a9847791620 |
institution | Directory Open Access Journal |
issn | 1867-1381 1867-8548 |
language | English |
last_indexed | 2024-12-12T10:37:35Z |
publishDate | 2010-08-01 |
publisher | Copernicus Publications |
record_format | Article |
series | Atmospheric Measurement Techniques |
spelling | doaj.art-ca61fa0758284a2d9f5c7a98477916202022-12-22T00:27:09ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482010-08-01341039105310.5194/amt-3-1039-2010A high-resolution mass spectrometer to measure atmospheric ion compositionH. JunninenM. EhnT. PetäjäL. LuosujärviT. KotiahoR. KostiainenU. RohnerM. GoninK. FuhrerM. KulmalaD. R. WorsnopIn this paper we present recent achievements on developing and testing a tool to detect the composition of ambient ions in the mass/charge range up to 2000 Th. The instrument is an Atmospheric Pressure Interface Time-of-Flight Mass Spectrometer (APi-TOF, Tofwerk AG). Its mass accuracy is better than 0.002%, and the mass resolving power is 3000 Th/Th. In the data analysis, a new efficient Matlab based set of programs (tofTools) were developed, tested and used. The APi-TOF was tested both in laboratory conditions and applied to outdoor air sampling in Helsinki at the SMEAR III station. Transmission efficiency calibrations showed a throughput of 0.1–0.5% in the range 100–1300 Th for positive ions, and linearity over 3 orders of magnitude in concentration was determined. In the laboratory tests the APi-TOF detected sulphuric acid-ammonia clusters in high concentration from a nebulised sample illustrating the potential of the instrument in revealing the role of sulphuric acid clusters in atmospheric new particle formation. The APi-TOF features a high enough accuracy, resolution and sensitivity for the determination of the composition of atmospheric small ions although the total concentration of those ions is typically only 400–2000 cm<sup>−3</sup>. The atmospheric ions were identified based on their exact masses, utilizing Kendrick analysis and correlograms as well as narrowing down the potential candidates based on their proton affinities as well isotopic patterns. In Helsinki during day-time the main negative ambient small ions were inorganic acids and their clusters. The positive ions were more complex, the main compounds were (poly)alkyl pyridines and – amines. The APi-TOF provides a near universal interface for atmospheric pressure sampling, and this key feature will be utilized in future laboratory and field studies.http://www.atmos-meas-tech.net/3/1039/2010/amt-3-1039-2010.pdf |
spellingShingle | H. Junninen M. Ehn T. Petäjä L. Luosujärvi T. Kotiaho R. Kostiainen U. Rohner M. Gonin K. Fuhrer M. Kulmala D. R. Worsnop A high-resolution mass spectrometer to measure atmospheric ion composition Atmospheric Measurement Techniques |
title | A high-resolution mass spectrometer to measure atmospheric ion composition |
title_full | A high-resolution mass spectrometer to measure atmospheric ion composition |
title_fullStr | A high-resolution mass spectrometer to measure atmospheric ion composition |
title_full_unstemmed | A high-resolution mass spectrometer to measure atmospheric ion composition |
title_short | A high-resolution mass spectrometer to measure atmospheric ion composition |
title_sort | high resolution mass spectrometer to measure atmospheric ion composition |
url | http://www.atmos-meas-tech.net/3/1039/2010/amt-3-1039-2010.pdf |
work_keys_str_mv | AT hjunninen ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT mehn ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT tpetaja ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT lluosujarvi ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT tkotiaho ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT rkostiainen ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT urohner ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT mgonin ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT kfuhrer ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT mkulmala ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT drworsnop ahighresolutionmassspectrometertomeasureatmosphericioncomposition AT hjunninen highresolutionmassspectrometertomeasureatmosphericioncomposition AT mehn highresolutionmassspectrometertomeasureatmosphericioncomposition AT tpetaja highresolutionmassspectrometertomeasureatmosphericioncomposition AT lluosujarvi highresolutionmassspectrometertomeasureatmosphericioncomposition AT tkotiaho highresolutionmassspectrometertomeasureatmosphericioncomposition AT rkostiainen highresolutionmassspectrometertomeasureatmosphericioncomposition AT urohner highresolutionmassspectrometertomeasureatmosphericioncomposition AT mgonin highresolutionmassspectrometertomeasureatmosphericioncomposition AT kfuhrer highresolutionmassspectrometertomeasureatmosphericioncomposition AT mkulmala highresolutionmassspectrometertomeasureatmosphericioncomposition AT drworsnop highresolutionmassspectrometertomeasureatmosphericioncomposition |